background image

Foundry EdgeIron 2402CF

Installation Guide

2100 Gold Street

P.O. Box 649100

San Jose, CA 95164-9100

Tel 408.586.1700

Fax 408.586.1900

www.foundrynetworks.com

February 2003

Содержание EdgeIron 2402CF

Страница 1: ...Foundry EdgeIron 2402CF Installation Guide 2100 Gold Street P O Box 649100 San Jose CA 95164 9100 Tel 408 586 1700 Fax 408 586 1900 www foundrynetworks com February 2003...

Страница 2: ...are the property of Foundry or other third parties You are not permitted to use these Marks without the prior written consent of Foundry or such appropriate third party Foundry Networks BigIron FastI...

Страница 3: ...u may use unshielded twisted pair UTP cable for RJ 45 connections Category 3 or greater for 10 Mbps connections Category 5 for 100 Mbps connections and Category 5 or 5e for 1000 Mbps connections Use 5...

Страница 4: ...00 4 2 1995 Contact Discharge 4 kV Air Discharge 8 kV Radio frequency electromagnetic field according to EN 61000 4 3 1996 80 1000 MHz with 1 kHz AM 80 Modulation 3 V m Electrical fast transient burst...

Страница 5: ...the Department of Communications Cet appareil num rique respecte les limites de bruits radio lectriques applicables aux appareils num riques de Classe A prescrites dans la norme sur le mat riel brouil...

Страница 6: ...qu il est sous tension Ne regardez jamais directement le port TX Transmission fibres optiques et les embouts de c bles fibres optiques tant qu ils sont sous tension Niemals ein bertragungslaser betra...

Страница 7: ...hlu werte 9 Verlegen Sie die Netzanschlu leitung so da niemand dar ber fallen kann Es sollte auch nichts auf der Leitung abgestellt werden 10 Alle Hinweise und Warnungen die sich am Ger t befinden sin...

Страница 8: ...s ist eine gepr fte Leitung zu verwenden F r einen Nennstrom bis 6 A und einem Ger tegewicht gr er 3 kg ist eine Leitung nicht leichter als H05VV F 3G 0 75 mm2 einzusetzen Der arbeitsplatzbezogene Sch...

Страница 9: ...Warranty Coverage 1 2 Related Publications 1 2 Chapter 2 About the Switch 2 1 Overview 2 1 Switch Architecture 2 2 Management Options 2 2 Description of Hardware 2 4 RJ 45 Ports 2 4 Port Status LEDs 2...

Страница 10: ...4 5 Chapter 5 Making Network Connections 5 1 Connecting Network Devices 5 1 Twisted Pair Devices 5 1 Cabling Guidelines 5 1 Connecting to PCs Servers Hubs and Switches 5 2 Wiring Closet Connections 5...

Страница 11: ...6 Adjusting Existing Category 5 Cabling B 6 Console Port Pin Assignments B 7 DB 9 Port Pin Assignments B 7 Console Port to 9 Pin DTE Port on PC B 7 Console to 25 Pin DTE Port on PC B 8 Appendix C Spec...

Страница 12: ...RXQGU 1HWZRUNV QF HEUXDU...

Страница 13: ...g typographical conventions to show information Italichighlights the title of another publication and occasionally emphasizes a word or phrase codeshows text that must be entered exactly as it appears...

Страница 14: ...o Services Technical Support Click the Login button then enter your user name and password to gain access to the Foundry support site E mail Access Technical requests can also be sent to the e mail ad...

Страница 15: ...p to 24 other switches can be cascaded from one switch providing broadband Internet access for up to 24 individual users on each switch Figure 2 1 Front and Rear Panels Media Slots Combo Gigabit Ether...

Страница 16: ...ore and forward switching and flow control maximum data integrity is always maintained even under heavy loading This switch includes two port 1000BASE SX and RJ 45 These ports allow users the flexibil...

Страница 17: ...collection of network nodes that share the same collision domain regardless of their physical location or connection point in the network By segmenting your network into VLANs you can Eliminate broadc...

Страница 18: ...ze incoming traffic based on input from the end station application These functions can be used to provide independent priorities for delay sensitive data and best effort data Description of Hardware...

Страница 19: ...t simplify installation and network troubleshooting The LEDs which are located on the front panel for easy viewing are shown below and described in the following tables Figure 2 2 Port Status LEDs Por...

Страница 20: ...Flashing indicates activity On Flashing Green Port has established a valid 1000 Mbps network connection Flashing indicates activity Off There is no valid link on the port System Status LEDs LED Condi...

Страница 21: ...n Amber The system diagnostic test has detected a fault Link N A This indicator is not currently implemented Duplex N A This indicator is not currently implemented Stack Flashing Amber An initial stat...

Страница 22: ...automatic MDI MDI X Unshielded UTP cable supported on all RJ 45 ports Category 3 4 or 5 for 10 Mbps connections and Category 5 for 100 Mbps connections IEEE 802 3 Ethernet and 802 3u Fast Ethernet co...

Страница 23: ...troubleshooting Management agent Supports Telnet SNMP and Web based interface Manages entire switch in band or out of band Private VLAN function providing port based security and isolation between po...

Страница 24: ...A BO U TT H ESW IT C H 2 10 2003 Foundry Networks Inc February 2003...

Страница 25: ...r power user or hub can be attached directly to a switched port And by using full duplex mode the bandwidth of the dedicated segment can be doubled to maximize throughput When networks are based on re...

Страница 26: ...thernet or Gigabit Ethernet However note that because switches break up the path for connected devices into separate collision domains you should not include the switch or connected cabling in your ca...

Страница 27: ...Distance for 1000BASE T Maximum Cable Distance for 10 100BASE Type Connector Maximum Cable Length Cat 5 5e or 6 100 ohm UTP RJ 45 100 m 328 ft Type Cable Type Maximum Cable Length 10BASE T Twisted Pai...

Страница 28: ...mode 2 When a switch is connected to a hub or any kind of shared media you may want to turn off back pressure flow control to prevent jamming packets from being propagated throughout the hub 3 As a ge...

Страница 29: ...ithin 10 to 90 non condensing provide adequate space approximately two inches on all sides for proper air flow be accessible for installing cabling and maintaining the devices allow the status LEDs to...

Страница 30: ...ort Fast Ethernet Switch Four adhesive foot pads Bracket Mounting Kit containing two brackets and four screws for attaching the brackets to the switch Power Cord RS 232 console cable Stacking Cable CD...

Страница 31: ...n the ambient room temperature check that the rack environment temperature is within the specified operating temperature range See page 2 Mechanical Loading Do not place any equipment on top of a rack...

Страница 32: ...ng the Switch in a Rack 3 If installing a single switch only turn to Connecting to a Power Source at the end of this chapter 4 If installing multiple switches mount them in the rack one below the othe...

Страница 33: ...on all sides for proper air flow 3 If installing a single switch only go to Connecting to a Power Source at the end of this chapter 4 If installing multiple switches attach four adhesive feet to each...

Страница 34: ...nded 3 pin socket 1RWH For International use you may need to change the AC line cord You must use a line cord set that has been approved for the receptacle type in your country 3 Check the front panel...

Страница 35: ...UTP cable with RJ 45 connectors at both ends For 1000BASE T Category 5 or 5e cable is required for 100BASE TX connections Category 5 cable is required for 10BASE T Category 3 4 or 5 cable can be used...

Страница 36: ...witch base unit support automatic MDI MDI X operation which means that they automatically detect the wiring in the link and configure as MDI or MDI X accordingly So for these ports you can use standar...

Страница 37: ...h 3 Make sure each twisted pair cable does not exceed 100 meters 328 ft in length 1RWH When connected to a shared collision domain such as a hub with multiple workstations switch ports must be set to...

Страница 38: ...d to the patch panel 2 If not already in place attach one end of a cable segment to the back of the patch panel where the punch down block is located and the other end to a modular wall outlet 3 Label...

Страница 39: ...HU RSWLF FDEOH 7KH ODVHUV DUH FRPSOLDQW ZLWK WKH UHTXLUHPHQWV RI D ODVV DVHU 3URGXFW DQG DUH LQKHUHQWO H H VDIH LQ QRUPDO RSHUDWLRQ RZHYHU RX VKRXOG QHYHU ORRN GLUHFWO DW D WUDQVPLW SRUW ZKHQ LW LV SR...

Страница 40: ...Inc February 2003 Figure 5 3 Making SC Port Connections 4 As a connection is made check the Activity LED on the switch s front panel for the corresponding module to be sure that the connection is vali...

Страница 41: ...tact your local dealer for assistance Link LED is Off Verify that the switch and attached device are powered on Be sure the cable is plugged into both the switch and corresponding device If the switch...

Страница 42: ...more components appear to be malfunctioning such as the power cord or network cabling test them in an alternate environment where you are sure that all the other components are functioning properly I...

Страница 43: ...2003 2003 Foundry Networks Inc A 3 1RWH The management agent accepts up to four simultaneous Telnet sessions If the maximum number of sessions already exists an additional Telnet connection will not b...

Страница 44: ...T R O U BLE SH O O TIN G A 4 2003 Foundry Networks Inc February 2003...

Страница 45: ...328 ft RJ 45 1000BASE SX 50 125 or 62 5 125 micron core MMF See the following table SC 1000BASE LX 9 125 micron SMF 5 km 3 12 miles SC 1000BASE T Cat 5 5e 100 ohm UTP 100 m 328 ft RJ 45 1000BASE SX F...

Страница 46: ...must be attached to the RJ 45 connectors in a specific orientation See Cabling Guidelines on page 1 for an explanation The figure below illustrates how the pins on the RJ 45 connector are numbered Be...

Страница 47: ...3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable For connection to hubs or switches which have MDI X ports a crossover cable must be us...

Страница 48: ...s must be straight through Crossover Wiring If the twisted pair cable is to join two ports and either both ports are labeled with an X MDI X or neither port is labeled with an X MDI a crossover must b...

Страница 49: ...P or shielded twisted pair STP cable for 1000BASE T connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Pi n MDI Signal Name MDI X Signal Name 1...

Страница 50: ...Installed Category 5 cabling must pass tests for Attenuation Near End Crosstalk NEXT and Far End Crosstalk FEXT This cable testing information is specified in the ANSI TIA EIA TSB 67 standard Additio...

Страница 51: ...board menu driven configuration program can be accessed from a terminal or a PC running a terminal emulation program The pin assignments used to connect to the serial port are provided in the followi...

Страница 52: ...ort on PC Switch s 9 Pin Se rial Port Null Modem PC s 9 Pin DTE Port 2 RXD TXD 3 TXD 3 TXD RXD 2 RXD 5 SGND SGND 5 SGND No other pins are used Switch s 9 Pin Se rial Port Null Modem PC s 25 Pin DTE Po...

Страница 53: ...r optional 1000BASE T 1000BASE SX 1000BASE LX and 1000BASE X GBIC modules Network Interface 10BASE T RJ 45 100 ohm UTP cable Categories 3 4 5 100BASE TX RJ 45 100 ohm UTP cable Category 5 Ports 1 24 R...

Страница 54: ...k Ports Link Activity Weight 3 08 kg 6 lb 13 oz Size 44 x 32 4 x 4 3 cm 17 32 x 12 8 x 1 69 in Temperature Operating 0 to 50 C 32 to 122 F Storage 40 to 70 C 40 to 158 F Humidity Operating 10 to 90 Po...

Страница 55: ...r Out of Band Management RS 232 DB 9 console port Software Loading TFTP in band or XModem out of band MIB Support MIB II RFC1213 Bridge MIB RFC 1493 without Static Table Standards IEEE 802 3 Ethernet...

Страница 56: ...TFTP RFC 783 TELNET RFC 783 SNMP RFC 1157 MIB II RFC 1213 Traps RFC 1215 Bridge MIB RFC 1493 RMON RFC 1757 HTML RFC 1866 HTTP RFC 2068 RADIUS RFC 2618 Compliances CE Mark Emissions FCC Class A Indust...

Страница 57: ...125 micron core fiber cable 1000BASE LH Gigabit Ethernet over two strands of 9 125 micron core fiber cable 1000BASE SX IEEE 802 3z specification for Gigabit Ethernet over two strands of 50 125 or 62...

Страница 58: ...s Collision Detect is the communication method employed by Ethernet and Fast Ethernet End Station A workstation server or other device that does not act as a network interconnection Ethernet A network...

Страница 59: ...tem based on Ethernet and the CSMA CD access method IEEE 802 3 Defines carrier sense multiple access with collision detection CSMA CD access method and physical layer specifications IEEE 802 3ab Defin...

Страница 60: ...puter and support devices Media Access Control MAC A portion of the networking protocol that governs access to the transmission medium facilitating the exchange of data between network nodes MIB An ac...

Страница 61: ...ndry Networks Inc Glossary 5 Transmission Control Protocol Internet Protocol TCP IP Protocol suite that includes TCP as the primary transport protocol and IP as the network layer protocol UTP Unshield...

Страница 62: ...Glossary 6 2003 Foundry Networks Inc February 2003...

Страница 63: ...C 4 safety C 4 connectivity rules 1000 Mbps 3 2 console port pin assignments B 7 contents of package 4 2 cooling problems A 2 cord sets international 4 6 crossover port 5 2 D desktop mounting 4 4 dev...

Страница 64: ...7 port saturation 2 3 ports connecting to 5 1 5 5 power connecting to 4 6 problems troubleshooting A 1 Q QoS 2 3 R rack mounting 4 3 rear panel receptacles 2 7 RJ 45 ports connections 5 1 description...

Страница 65: ...Index February 2003 2003 Foundry Networks Inc Index 3 problems A 2 switch indicators A 1 twisted pair connections 5 1 V VLANs 2 3 W Web based management 2 2 Weighted Round Robin Queuing 2 4...

Страница 66: ...QGH Index 4 2003 Foundry Networks Inc February 2003...

Отзывы: