manualshive.com logo in svg
background image

Issue Date: 10-29-99

Rev. Date: 9-13-05

Rev. Level: 04

ECN: N/A

OIPM P/N 3420365

Page 1 of 7

REQUIRED CLEARANCE

Caution - Spacing: (suspension mount) Heaters must
be mounted a minimum of 24" from a vertical surface,
72” from the floor and direct radiation to combustibles,
and 24” from the ceiling

.

WARNING!

DO NOT ATTEMPT TO INSTALL, OPERATE, OR SERVICE THIS PRODUCT BEFORE READING ALL

INSTRUCTIONS CAREFULLY. FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN

FIRE

,

PERSONAL

I

NJURY

AND/OR

PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE

.

Fostoria Dual Heat Heaters are designed to provide
efficient

spot

heating

for

construction

sites,

farms,

warehouses, garages, truck docks, paint and plaster
drying, etc.

Not for indoor residential use.

Reflectors are

gold anodized aluminum. Heaters are equipped with steel
grid type protective guards. Two separate toggle switches
allow for dual heat control. Four bolts are provided to
mount heater to hand truck (if ordered), and slots are
provided for chain suspension (chain and “S” hooks
included). Heaters have a 45º symmetric heat pattern, and
may be used up to a 20-ft. distance from the area to be
heated.

DESCRIPTION

Heat source

……....…………...……………..………5/8” Dia. Quartz Tube

Element Life (Avg.)

……..………................………………….....5000 Hrs.

Wire Guard

...………………..…………………….…0.125” Dia. Steel Wire

Housing

……………………….………….…20 gauge Galvannealed Steel

CH-6424-1C

Powercord

…………..…15’, 10/3 Grounded Type w/ Nema L6-30P Plug

Power Requirements

…………………………………………….……240V

Dimensions

………………………………………….…….19” x 32” x 3-3/4”

Element Wattage

…………………………………………….…………1425

CH-2212-1C

Powercord

…....15’, 14/3 Grounded Type w/ Molded Nema 5-20P Plug

Power Requirements

………………………………………………….120V

Dimensions

…………………………………………….….11” x 23” x 3-3/4”

Element Wattage

………………………………………………….……1000

SPECIFICATIONS

Read all instructions before using this heater.

1.

Make certain that the power source conforms to the
electrical requirements of the heater

2.

Unplug power cord before installing or servicing.

WARNING: DO NOT DEPEND UPON A THERMOSTAT OR
OTHER

SWITCH

AS

THE

SOLE

MEANS

OF

DISCONNECTING

POWER

WHEN

INSTALLING

OR

SERVICING THE HEATER. ALWAYS UNPLUG THE HEATER.
FAILURE TO DO SO COULD RESULT IN FATAL ELECTRIC
SHOCK.

3.

NEVER

leave the heater unattended for extended periods,

while it is in operation.

4.

Power

cord

is

equipped

with

a

three-wire

bonding

(grounding) type plug that must be inserted into a matching
receptacle.

Under no circumstances should the bonding

prong be cut off plug. Where a two-prong wall receptacle is
encountered, it must be replaced with a properly bonded
(grounded) three-prong receptacle installed in accordance
with the National Electric Code (NEC) and all applicable
local codes and ordinances. This work must be done only
by

a

qualified

electrician,

using

copper

wire

only.

WARNING: USE OF A THREE-PRONG TO TWO-PRONG
ADAPTER

IS

NOT

RECOMMENDED.

Improper

connection may create the risk of electrocution. Use of
such adapters is not permitted in Canada. This applies
to Model CH-2212-1C.

IMPORTANT SAFETY INFORMATION

5.

All wiring should be performed by a qualified electrician.

6.

This heater can be used for 120V, single phase (Model CH-
2212-1C), or 240V,single phase (Model CH-6424-1C). These
units are supplied with 3-wire cordsets for portability.

To

reduce the risk of electric shock, the heater must be
securely and adequately bonded (grounded)!

This can be

accomplished by either: 1) Inserting the plug directly into a
properly

installed

and

bonded

3-prong

bonding

type

receptacle.

2) Permanently wiring the unit with a bonded,

metal raceway system.

3) Using a separate bonding wire

connected to the bare metal of the heater.

4) Using other

suitable means. The green (or green and yellow) conductor in
the cord is the bonding (grounding) wire.

WARNING:

Never connect the green (or green and yellow)

wire to a live terminal!

7.

Where possible, avoid the use of extension cords.

If they

must be used, minimize the risk of overheating by ensuring
that they are UL Listed and are of the proper gauge and
length, and that they have 3-prong bonding (grounding) type
plugs. Use 3-pole receptacles that accept the 3-prong plugs.
Never use a single extension cord to operate more than one
heater.

8.

Do not insert fingers or foreign objects into the heater. Do not
block or tamper with the heater while it is in operation. Do not
touch heater while it is in operation or just after it has been
turned off, as some parts may be hot enough to cause injury.

INFRARED HEATER

MODEL & PART NO.:

CH-2212-1C

(08840910)

CH-6424-1C

(08841010)

*FHK-1

(08524002)

* THE ETL CERTIFICATION DOES NOT INCLUDE

THE HEATERS MOUNTED ON A CART (FHK-1)

OPERATION – INSTALLATION – PARTS

MANUAL

If you have questions about the

product you have purchased or would

like to leave us feedback please

contact us via our website

www.fostoriaindustries.com

or by calling 1-800-495-4525.

Содержание CH-6424-1C

Страница 1: ...o circumstances should the bonding prong be cut off plug Where a two prong wall receptacle is encountered it must be replaced with a properly bonded grounded three prong receptacle installed in accordance with the National Electric Code NEC and all applicable local codes and ordinances This work must be done only by a qualified electrician using copper wire only WARNING USE OF A THREE PRONG TO TWO...

Страница 2: ...BACKUP SYSTEM S SHOULD BE USED 1 For chain suspension the 4 S hooks with chain should be used to insert into the loops on the back of the heater Loops are on 27 3 8 x 17 centers for Model CH 6424 1C and 18 3 8 x 7 centers for Model CH 2212 1C These heaters should always be mounted so that the quartz tubes are horizontal or tube burnout will occur 2 Be sure that the power source conforms to the hea...

Страница 3: ...6715056 40493001 7715010 3406956 3427556 7714114 3440300 QTY 1 1 2 1 4 1 4 2 2 2 10 4 1 1 REF NO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 DESCRIPTION Housing assembly Reflector End cap Wireguard Self retaining nut 1 4 20 Cord Socket assembly Quartz tube 1425 watt 240 volt Toggle switch 20A at 125 250V Switch plate ON OFF not shown HHD Screw 6 20 x 3 8 Hex head screw 1 4 20 x 1 2 g Cable connector 3 4 n...

Страница 4: ...mentación cuenta con clavija de tres puntas y conexión a tierra la cual debe conectarse a una toma de corriente compañera En ninguna circunstancia debe cortarse la punta de tierra de la clavija En los casos en que la toma de corriente sólo cuente con dos contactos debe sustituirse con una de tres para que proporcione una apropiada conexión a tierra de conformidad con el Reglamento Nacional de Inst...

Страница 5: ...en insertarse en la parte posterior del calentador Hay aros cuyos centros están en los puntos 70 cm x 43 cm 27 3 8 x 17 en el Modelo CH 6424 1C y en los puntos 47 cm x 18 cm 18 3 8 x 7 en el Modelo CH 2212 1C Estos calentadores siempre deben de montarse de manera que los tubos de cuarzo queden horizontales o de lo contario se funden 2 Asegúrese de que el suministro de energía eléctrica satisface l...

Страница 6: ...40493001 7715010 3406956 3427556 7714114 3440300 CANT 1 1 2 1 4 1 4 2 2 2 10 4 1 1 NO REF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 DESCRIPCIÓN Ensamble de la caja Reflector Tapa del extremo Guarda de alambre Tuerca autorretención 1 4 20 Cordón Conjunto del receptáculo Tubo de cuarzo 1425 W 240 V Interrpt palanca 20A a 125 o 250V Placa interrpt ON OFF no aparece Tornillo cab hex 6 20 x 3 8 Tornillo cab ...

Страница 7: ...an implied warranty lasts The above exclusions or limitations may not apply to you During the warranty period TPI Corporation will at its sole option repair or replace any defective parts or products returned freight prepaid to the TPI Corporation factory or such other locations as TPI Corporation may designate Returned products must be packaged carefully and TPI Corporation shall not be responsib...

Отзывы: