Bridge GUI Guide: Security Configuration
163
To configure audit logging
by event type, Fortress security status and interface:
1
Log on to the Bridge GUI through an
Administrator
-level
account and select
ADVANCED
VIEW
in the upper right corner
of the page, then
Configure
->
Logging/Auditing
from the
menu on the left.
2
In the
Logging/Auditing
screen’s
Global Auditing Settings
frame, enter new values for the controls you want to
configure. (Your options are described in sections 4.6.2.1
and 4.6.2.2).
NOTE:
Changes to
administrative au-
dit logging take effect at
the next administrator
logon.
3
Click
APPLY
in the upper right of the screen (or
RESET
screen settings to cancel your changes).
4.6.2.3
Logging Administrative Activity by MAC Address
You can filter administrative activity sent to the audit log by the
MAC address from which it originates.
The same categories of interfaces and Fortress security status
of origin used to globally configure administrative audit logging
apply when you configure audit event logging by individual
MAC address (refer to Section 4.6.2.2).
Audit by User Interface
- includes the possible administrative
network interfaces:
SSH
,
GUI
,
SNMP
Audit by Fortress Security
- includes
Clear Interfaces
and
Encrypted Interfaces
.
NOTE:
The
Wire-
less
interface type
does not apply to Bridg-
es without radios and
will not be present for
those models (refer to
Table 1.1 on page 3).
Audit by Interface Type
- includes
Wired
and
Wireless
interfaces.
Each control can be set to one of the same three behaviors
described in Section 4.6.2.2:
Required
,
Prohibited
,
Auto
.
Events originating from the MAC address are checked against
the audit settings for
User Interface
, and
Fortress Security
and
Interface Type
, in that order, and logged according to the first
applicable
Required
or
Prohibited
setting.
In new MAC address entries, logging is
Required
by default for
all interfaces, regardless of user, type, or Fortress security
status.
Figure 4.25. Advanced View
MAC Auditing Settings
frame, all platforms
To configure audit logging by MAC address:
1
Log on to the Bridge GUI through an
Administrator
-level
account and select
ADVANCED
VIEW
in the upper right corner
of the page, then
Configure
->
Logging/Auditing
from the
menu on the left.