Description
S40
IR
Escape Release Adaptor module is used in conjunction with a releasing
amGard
S40
unit, to provide an escape function from an interlocked hazardous
area. There are three versions, one with a key reset, one with a push button
reset and one with a simple pull reset. The other option is the length of plunger
needed to clear the door post thickness. This unit must always be mounted as
the first module under the head.
Note: Releasing versions of other modules are the type that
MUST
be used in
conjunction with this module. This module
MUST
be mounted directly below the
head module.
Options & Ordering Information
Description
Post Thickness
Part No.
Key Reset
60mm
S40R2
Key Reset
80mm
S40R3
Key Reset
Variable*
S40R4
Pull Reset
60mm
S40R7
Pull Reset
80mm
S40R8
Pull Reset
Variable*
S40R9
Front Reset (no key)
60mm
S40RX
Front Reset (no key)
80mm
S40RY
Front Reset (no key)
Variable*
S40RZ
*Suitable for increased post thicknesses up to a maximum of 350mm. For any greater post thickness additional support may be required, contact your
Fortress representative.
Important:
This product is designed for use according to the installation and operating instructions enclosed. It must be installed
by competent and qualified personnel who have read and understood the whole of this document prior to commencing
installation. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment
may be impaired. Any modification to or deviation from these instructions invalidates all warranties. Fortress Interlocks Ltd
accepts no liability whatsoever for any situation arising from misuse or misapplication of this product.
Note: The availability of spare Actuators and Keys makes it possible to easily bypass the safety devices and, for
this reason, the security of any spare Actuators and Keys must be effectively monitored.
DO NOT LEAVE OVERRIDE/RESET KEY IN PLACE!
Always keep it in a secure place, under management control, as it allows access to areas that may have a residual
hazard,and may result in incorrect operation of some devices.
BEWARE OF INTENTIONAL MISUSE CAUSED BY OPERATORS WANTING TO BYPASS SAFETY SYSTEMS. THE
INSTALLER SHOULD ASSESS THE RISKS AND MITIGATE AGAINST THEM.
Safety switches (such as a Stop or LOK) must be fitted in conjunction with this unit to monitor when the Escape
Release has been activated. When lock adaptors are also used it is not possible to change a Stop to a LOK (and
vice versa) without other changes to the locks - seek advice from Fortress.
IF YOU HAVE ANY QUESTIONS OR QUERIES OF ANY NATURE WHATSOEVER PLEASE CONTACT THE SUPPLIER
WHO WILL BE PLEASED TO ADVISE AND ASSIST.
Adaptors
Gard
S40
Operating Instructions: S40 IR - Escape Release Adaptor
1