![Fortinet FortiGate-7000E Series Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/fortinet/fortigate-7000e-series/fortigate-7000e-series_system-manual_2321753051.webp)
FortiGate-7060E System Management Modules
Fortinet Technologies Inc.
LED
State
Description
Power
Solid green
Normal operation.
Blinking green
Chassis 12V disabled. This means that the administrator has
entered commands into the SMM CLI to power off the PSU
main 12V outputs. All fans, FIM and FPM modules are
completely powered off but the SMM is still running.
Red
Chassis 12V enabled but not OK. This means the SMM has
enabled the main 12V outputs for all chassis components, but
the power OK (PWOK) signal of at least one PSU has not
been sent. When a PSU is powering up, it would be normal
for this LED to be red for a second (before PSU outputs are
stabilized), but if LED remains red, it indicates a problem
(such as a failed PSU). SMM or FIM or FPM module voltage
sensors would most likely also trigger alarms if this happens
since the PSUs may not be delivering enough power.
FAN (LEDs for each of
three fan trays)
Off
Fan tachometer sensors disabled. This could happen if the
administrator disabled them from the SMM CLI.
Green
The fan tray is operating normally.
Blinking red
The fan tray is not working. Chassis cooling may be sufficient
but redundancy is lost and the fan tray that is not working
should be replaced.
Red
A fan tachometer sensor in this fan tray has registered an
alert because a critical or non-recoverable (NR) threshold has
been crossed.
PSU (LEDs for each of six
PSUs)
Off
The PSU is not installed in the chassis.
Green
The PSU is present and operating normally.
Blinking red
The PSU module is installed but no power is being delivered
(not plugged in).
Red
The PSU's sensors have detected an alert condition. The
PSU's analog sensors crossed critical or non-recoverable (NR)
thresholds, or the PSU Status Failure bit has been set.
Console 1 and 2
Off
This console port is not connected or is connected to the
SMM SMM CLI.
Green
This console port is connected to this module host console in
this chassis slot.
Amber
This console port is connected to this module's SMC console.
About SMM alarm levels
Minor, major, and critical alarms are defined based on both IPMI, ATCA, and Telco standards for naming alarms.
FortiGate-7060E 6.4.2 System Guide
51