Environmental Specifications

Cautions and Warnings

Cautions and Warnings

Environmental Specifications

Rack Mount Instructions

- The following or similar rack-mount instructions are included with the installation

instructions:

Instructions de montage en rack

- Les instructions de montage en rack suivantes ou similaires sont incluses

avec les instructions d'installation:

Elevated Operating Ambient

- If installed in a closed or multi-unit rack assembly, the operating ambient

temperature of the rack environment may be greater than room ambient. Therefore, consideration should be
given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma)
specified by the manufacturer.

Température ambiante élevée

– S'il est installé dans un rack fermé ou à unités multiples, la température

ambiante de fonctionnement de l'environnement du rack peut être supérieure à la température ambiante de la
pièce. Par conséquent, il est important d’installer le matériel dans un environnement respectant la température
ambiante maximale (Tma) stipulée par le fabricant.

Reduced Air Flow

- Installation of the equipment in a rack should be such that the amount of air flow required

for safe operation of the equipment is not compromised.

Ventilation réduite

– Installation de l'équipement dans un rack doit être telle que la quantité de flux d'air

nécessaire au bon fonctionnement de l'équipement n'est pas compromise.

Mechanical Loading

- Mounting of the equipment in the rack should be such that a hazardous condition is not

achieved due to uneven mechanical loading.

Chargement Mécanique

– Montage de l'équipement dans le rack doit être telle qu'une situation dangereuse

n'est pas lié à un chargement mécanique inégal.

Circuit Overloading

- Consideration should be given to the connection of the equipment to the supply circuit

and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing this concern.

Surtension

– Il convient de prendre l’ensemble des précautions nécessaires lors du branchement de

l’équipement au circuit d’alimentation et être particulièrement attentif aux effets de la suralimentation sur le
dispositif assurant une protection contre les courts-circuits et le câblage. Ainsi, il est recommandé de tenir
compte du numéro d’identification de l’équipement.

Reliable Earthing

- Reliable earthing of rack-mounted equipment should be maintained. Particular attention

should be given to supply connections other than direct connections to the branch circuit (e.g. use of power
strips).

22

FIM-7904E Interface Module Guide

Fortinet Technologies Inc.

Содержание FIM-7904E

Страница 1: ...FIM 7904E Interface Module Guide 7000...

Страница 2: ...t com how to work with fortinet support FORTIGATE COOKBOOK http cookbook fortinet com FORTINET TRAINING SERVICES http www fortinet com training FORTIGUARD CENTER http www fortiguard com FORTICAST http...

Страница 3: ...board from a chassis 16 Troubleshooting 18 FIM 7904E does not startup 19 FIM 7904E status LED is flashing during system operation 19 Quick FIM 7904E configuration 20 Registering your FortiGate 7000 se...

Страница 4: ...ent Interface Status Alarm HA and Power LEDS USB Power Button NMI Button The FIM 7904E includes the following hardware features l Eight front panel 40GigE QSFP fabric channel interfaces B1 to B8 These...

Страница 5: ...troubleshooting as recommended by Fortinet Support l Mounting hardware l LED status indicators Physical Description Dimensions 1 2 x 11 34 x 14 in 3 1 x 28 8 x 35 1 cm Height x Width x Depth Weight 7...

Страница 6: ...Off No link is established M1 and M2 Green The correct cable is connected to the interface and the connected equipment has power Flashing Green Network activity at the interface Off No link is establi...

Страница 7: ...on FG TRAN QSFP SR 40GE QSFP transceivers short range FG TRAN QSFP LR 40GE QSFP transceivers long range Breakout cables available from Fortinet for the FIM 7904E B1 to B8 QSFP interfaces Breakout Desc...

Страница 8: ...t like any other FortiGate interface Turning the module on and off You can use the front panel power button to turn the module power on or off If the module is powered on press the power switch to tur...

Страница 9: ...hitecture FIM 7904E hardware architecture Chassis Base Backplane Chassis Fabric Backplane CPU Integrated Switch Fabric Management MGMT1 4 Heartbeat M1 M2 Data B1 B8 DP2 DP2 DP2 1G 80G 40G FIM 7904E In...

Страница 10: ...bps The M1 and M2 interfaces are used for heartbeat session sync and management communication between FIM 7904Es in different chassis This communication requires 10 Gbps connections so even though it...

Страница 11: ...slot and are used to insert and eject the module from the slot On some FIM modules there may be very little clearance between the front panel interfaces and the handle on the right side of the FIM 79...

Страница 12: ...ered on To insert a FIM 7904E into a chassis slot Do not carry the FIM 7904E by holding the handles or retention screws When inserting or removing the FIM 7904E from a chassis slot handle the module b...

Страница 13: ...le FIM 7904E is being installed into chassis slot 1 of a FortiGate 7040E chassis 2 Unlock the left and right handles by pushing the handle latches up about 2 mm until the handles pop open Fully open b...

Страница 14: ...e sliding the module in the module could be aligned incorrectly Pull the module back out and try inserting it again 4 Push both handles closed and close the latches Closing the handles draws the modul...

Страница 15: ...s to be adjusted between 3 In lb to 4 In lb 0 4 N m to 0 48 N m As the latches are locked power is supplied to the module If the chassis is powered on during insertion the status LED flashes green as...

Страница 16: ...ndles or retention screws When inserting or removing the FIM 7904E from a chassis slot handle the module by the front panel The handles are not designed for carrying the board If the handles become be...

Страница 17: ...ust fully loosen the screws or the handles may be damaged when used to eject the board from the chassis slot 2 Unlock the left and right handles by pushing the latches up about 2 mm until the handles...

Страница 18: ...oderate force to eject the module from the chassis 4 Hold the module front panel sides and slide it part way out of the slot Then grasp the module by the sides and carefully slide it out of the slot T...

Страница 19: ...with FortiOS Connect to the FIM 7904E console and try cycling the power to the board If the BIOS starts up interrupt the BIOS startup and install a new firmware image If this does not solve the proble...

Страница 20: ...oduct by visiting https support fortinet com To register enter your contact information and the serial numbers of the Fortinet products that you or your organization have purchased Choosing the config...

Страница 21: ...and start over From the CLI enter execute factoryreset Connect to the GUI by connecting MGMT1 of the module in slot 1 to your network and browsing to https 192 168 1 99 Log into the GUI using the admi...

Страница 22: ...sed Ventilation r duite Installation de l quipement dans un rack doit tre telle que la quantit de flux d air n cessaire au bon fonctionnement de l quipement n est pas compromise Mechanical Loading Mou...

Страница 23: ...ent intended for installation in Restricted Access Location Avertissement Le mat riel est con u pour tre install dans un endroit o l acc s est restreint Warning A readily accessible disconnect device...

Страница 24: ...green with yellow stripe conductor minimum size 6 AWG and the connection is to be installed by a qualified service personnel Ce produit a une borne de mise la terre s par sur le dos de l appareil en...

Страница 25: ...residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING Any changes or modifications to this product not...

Страница 26: ...gulatory Notices Voluntary Control Council for Interference VCCI Japan Product Safety Electrical Appliance Material PSE Japan PSE Bureau of Standards Metrology and Inspection BSMI Taiwan China A 26 FI...

Страница 27: ...inet enters a binding written contract signed by Fortinet s General Counsel with a purchaser that expressly warrants that the identified product will perform according to certain expressly identified...

Отзывы: