![Fortinet FIM-7901E Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/fortinet/fim-7901e/fim-7901e_manual_2321744007.webp)
FIM-7901E interface module
7
Connector
Type
Speed
Protocol
Description
connect to the base backplane channel. These
interfaces are used for heartbeat, session sync,
and management communication between FIM-
7901Es in different chassis. These interfaces can
also be configured to operate as Gigabit Ethernet
interfaces using SFP transceivers, but should not
normally be changed. If you use switches to
connect these interfaces, the switch ports should
be able to accept packets with a maximum frame
size of at least 1526. The M1 and M2 interfaces
need to be on different broadcast domains. If M1
and M2 are connected to the same switch, Q-in-
Q must be enabled on the switch
MGMT1 to
MGMT4
RJ-45
10/100/1000Mbps
Ethernet
Four 10/100/1000BASE-T copper out of band
management Ethernet interfaces.
USB
USB 3.0
Type A
USB 3.0 USB
2.0
Standard USB connector.
Physical description
Dimensions
1.88 x 17.11 x 18.49 in. (48 x 435 x 470 mm) (Height x Width x Length)
Weight
16 lb. (7.3 kg)
Operating Temperature
32 to 104°F (0 to 40°C)
Storage Temperature
-31 to 158°F (-35 to 70°C)
Relative Humidity
10% to 90% (Non-condensing)
Power consumption
Max: 450W; Average: 400W
Max Current
37.5A
Heat Dissipation
1531BTU/h
Joules/h
1609KJ/h
Front panel LEDs
From the FIM-7901E font panel you can view the status of the module LEDs to verify that the module is functioning
normally.
FIM-7901E Processing Module Guide
Fortinet Technologies Inc.