Running the automatic feeder
65
10. Insert the mains plug again and turn on the automatic feeder again using the control
switch.
11. Press
until the message
Start automatic mode?
appears in your display.
12. Confirm
Start automatic mode?
by choosing
.
The automatic feeder is now operating in automatic mode again.
6.4.3.3 Circuit cleaning
With circuit cleaning, you simultaneously clean the suction hoses
Use the mounting holders provided for this procedure.
1
2
3
4
6
5
1 Hose nozzle
4 Suction hose (first station)
2 Cleaning adaptor
5 Suction hose (second station)
3 Rubber closing cap
6 Coupling for milk supply
Run circuit cleaning at least
once a day
if automatic mixer cleaning is not enabled.
Run circuit cleaning at least
once a week
if automatic mixer cleaning is enabled.
You set circuit cleaning as follows:
1. Choose
> Cleaning
to go to the
Circuit cleaning
submenu.
2. In
Water/station
, you enter the desired amount of water. You can enter values from 0.5 l to
1.5 l. The preset default value is 1 l.
Note:
The longer the hoses, the higher the value you must select.
3. Confirm
start?
by choosing
.
The message
Exit automatic mode?
appears in the display.
Содержание TAP5-CH2-25
Страница 2: ......
Страница 6: ...6 Table of contents ...
Страница 31: ...Operating the automatic feeder 31 4 2 1 The 15 key hand terminal 1 Keypad 2 Auto LED 3 Display ...
Страница 102: ...102 Running the automatic feeder ...
Страница 119: ...Appendix 119 9 Appendix 9 1 Feeding 9 1 1 Standard feeding plans 9 1 1 1 Group A ...
Страница 120: ...120 Appendix 9 1 1 2 Group B 9 1 1 3 Group C ...
Страница 121: ...Appendix 121 9 1 1 4 Group D ...
Страница 122: ...122 Appendix 9 1 1 5 Template for individual feeding plan ...
Страница 123: ...Appendix 123 9 1 2 Basic principle of interval feeding ...