![formlabs Fuse 1 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/formlabs/fuse-1/fuse-1_manual_2320173049.webp)
Maintenance |
47
3. Disconnect the vacuum hose from the side of the Fuse Sift.
4. Turn on the vacuum by pushing the
Vac
button on the control panel or by tapping the
vacuum hose icon on the touchscreen.
5. Vacuum the loose powder on the print enclosure floor. Avoid touching the gaskets around
the door with the vacuum hose.
6. Vacuum the air filter.
7. Turn off the vacuum by pushing the
Vac
button on the control panel or by tapping the
vacuum hose icon on the touchscreen.
8. Close the print enclosure door.
9. Reconnect the vacuum hose to the port on the side of the Fuse Sift.
6.4.6
Purging the exhaust lines
With typical use, marginal amounts of powder and laurolactam can accumulate in the exhaust lines. It
is important to periodically purge the exhaust lines to maintain airflow out of the print enclosure. Purge
the exhaust lines after 10–15 full build volume prints or 500 hours of printing, whichever comes first.
Before proceeding, ensure that the build chamber is removed from the print
enclosure and that an optical cassette is installed.
To purge the exhaust lines:
1. Drag the Open Door slider on the touchscreen. The print enclosure door unlocks.
2. Open the print enclosure door on the printer.
Ensure that the print enclosure door is open before continuing. If the print enclosure
door remains shut while you purge the exhaust lines, powder may be drawn from the
hopper into the print enclosure and cause the next print to fail.
3. Open the air filter door on the right side of the printer.
4. Turn off the printer using the rear breaker switch.
5. Disconnect the vacuum hose from the side of the Fuse Sift.
6. Turn on the vacuum by pushing the
Vac
button on the control panel or by tapping the
vacuum hose icon on the touchscreen.
7. Locate the circular exhaust port inside the filter cabinet, to the right of the rectangular
exhaust filter.
8. Hold the vacuum hose up to the port for 60 seconds.
9. Locate the circular inner exhaust line port, located on the rear wall of the print enclosure. If
a build chamber is inserted into the printer, remove it to access the inner exhaust line port.
10. Hold the vacuum hose up to the port for 60 seconds.
11. Turn off the vacuum by pushing the Vac button on the control panel or by tapping the
vacuum hose icon on the touchscreen.
12. Close the filter door on the right side of the printer.
13. Close the print enclosure door.
14. Turn the printer back on.
15. Reconnect the vacuum hose to the port on the side of the Fuse Sift.