![formlabs Form Cure L Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/formlabs/form-cure-l/form-cure-l_installation-and-usage-instructions_2320176022.webp)
20
4.7
Updating firmware
For detailed guidance and visual assistance, visit
.
Formlabs regularly releases updated firmware to fix bugs and improve functionality. Download
the latest firmware version for your Formlabs device with PreForm, then upload and install
the firmware file on the machine. Refer to the
firmware downloads and release notes
more about the improvements that come with each version’s release.
To update the firmware via PreForm:
1. Open PreForm.
2. Connect the machine to the computer via USB or connect the device to an Ethernet network.
3. Click
File > Devices
. The
Device List
window appears.
4. Click the machine’s serial name. The
Device Details
window opens.
5. Click
Update
in the upper-right corner of the
Device Details
window. The
Firmware Update
window opens.
6. Follow the on-screen instructions to download the latest firmware and then upload the file
to the machine. To upload firmware, the device must be connected to the computer via
USB or the machine must be connected to an Ethernet network.
7. The machine may automatically recognize that you have sent a firmware update. Tap
Continue
on the touchscreen to finish the installation.
8. If you are not prompted to
Continue
, continue the firmware update manually. Tap
Settings
> System > Firmware Update
.
9. After the firmware update installs, confirm the system restart on the touchscreen or wait 30
seconds for an automatic restart.
4.8
Transporting the machine
For detailed guidance and visual assistance, visit
.
Refer to section
4.3.1 Receiving
for product weight and dimensions. Keep the packaging for
transportation or shipping.
The complete packaging kit consists of:
•
1 outer carton, cardboard
•
1 upper insert, foam
•
1 carrier tray, cardboard
•
2 carrying slings, cardboard
•
1 carrier tray insert, foam
4.8.1
Preparing for transportation
Before repackaging, remove the glass turntable and place it in the accessories box. Ensure
the post-cure chamber as well as the outer shells are clean and dry.
The Form Cure L is a heavy object. A two person lift is required to prevent injury and avoid
damage to the machine. Always use the included cardboard slings when moving the device.
Do not ship the machine without removing and fully securing the turntable. The
turntable is made of glass and can break during transit.
CAUTION
NOTICE