Service\Repair                                                                        Formech FM660                      

 

 

Vacuum / pressure system 

If the vacuum or pressure appears to be weak or non-existent check the following. 

 

The mould baseboard is not restricting the vacuum inlet in the drape table. 

 

NOTE:  If  the  mould  baseboard  is  too  soft  it  may  pull  down  under  vacuum  and  block  the 
vacuum inlet. 

 

The mould is adequately vented to allow trapped air to be evacuated. 

 

The table and clamp seals are in good order and the table is locking properly at the top of its 
travel. 

 

There are no holes drilled in the drape table. 

 

The filer box cover is correctly fitted. 

 

If all the above points are OK and you can hear the pump running when you switch it on then one of 
the following points will be the cause of the problem.  If the pump does not run, refer to the Electrical 
trouble shooting section above. 

 

A pipe is loose, damaged or blocked. 

 

The pump filter is blocked 

 

The vacuum\pressure valve is blocked or corroded. 

 

The vacuum pump is blocked or corroded. 

If the heater has been left in the forward position, with no plastic in the clamp frame, the table will start 
to overheat.    The  pipe  attached  to  the  back  of  the  table  will  shrink  and  constrict  the  passage  of  air.  
Pipes become less flexible over time and may loosen or crack. 

 

Pneumatics (FM660PT version only) 

Check oil in lubricator daily. 

 

Providing there is a good filtered regulated and lubricated air supply, using a  good quality airline  oil, 
maintenance will be minimal. However, a thorough inspection of the machine is necessary from time 
to  time.  Any  mechanical  damage  of  pipes  and  fittings  should  be  dealt  with  before  re-using  the 
machine.  

Always lock air supply OFF and bleed out system air before attempting any maintenance of air 
system.

  

Other problems that cylinders and solenoid valves may suffer from are: - 

 

Lack of electrical supply - Check appropriate circuitry. 

 

Solenoid has become open circuit - Replace with new solenoid. 

 

Return mechanism jammed or broken - Dismantle valve to investigate.  

             Replace if required. 

 

Wet  or  dirty  air  supply  -  Check  condition  of  air  compressor  and  condensate  management 
system. 

 

Internal leaks within valves & cylinder. 

 

 

Содержание FM660

Страница 1: ...r table and clinica version Single Heater Vacuum Forming Machine Installation Operating and Service Manual For Parts Service Technical Assistance Telephone 44 0 1582 46 97 97 Fax 44 0 1582 46 96 46 Em...

Страница 2: ...and use 9 Operating Procedure 10 Operating Techniques 11 Heaters 11 Heater timer 12 Bubble moulding 12 Tools 13 Plastics 14 Post Forming Operations 14 After forming 14 Trimming 14 Forming Difficulties...

Страница 3: ...derstand that high pressures may be present within parts of the pneumatic system even after the supply has been isolated Special care must be taken if any parts have become jammed to ensure that all p...

Страница 4: ...ry from compressed air Pressures up to 100 PSI will be present in large volumes on this machine BE EXTRA CAUTIOUS WHEN DEALING WITH COMPRESSED AIR EVEN AFTER MAIN SUPPLY HAS BEEN SHUT OFF DANGEROUS RE...

Страница 5: ...formed A countdown timer is fitted as standard The machine has been designed to be highly adaptable and functions such as changing a mould or fitting reducing windows which allow smaller sheets to be...

Страница 6: ...ndard voltage 220 240V S Phase Forming area 620mm x 620mm 380 415V 3 Phase Depth of draw 400mm Standard frequency 50 60Hz Mat thickness 6 0mm max Standard max Power 7550W Overall height 1280mm Overall...

Страница 7: ...ressure must not exceed 6BAR or 80 PSI Attaching the stabiliser bar arrangement The kit comprises two sidepieces one stabiliser bar and fixing screws 1 Remove the two lower screws from each side of th...

Страница 8: ...bolts supplied The fan mounting post should be attached to the cross member so that the fan can be positioned behind the cross member directing the fan draft forward away from the heater 3 The swivel...

Страница 9: ...pply vacuum to the table hole Pressing any sequence button will unlatch this function Cooling Fan There is an ON and an OFF button for this function No other buttons will affect the fan operation Rele...

Страница 10: ...ating cycle time is known then the timer can be set prior to bringing the heater forward If not using the timer push the heater back slightly to test the softness of the plastic manually or to observe...

Страница 11: ...that the rear of the heater will always run hotter than the front Having set the heaters slight adjustments may have to be made depending on the mould design plastic type thickness colour and the mach...

Страница 12: ...s down the seconds to give a useful indication of the heat time remaining An audible bleep is given when the countdown is complete and the display resets to the pre set time The buzzer indicates that...

Страница 13: ...the plastic sheet before it can take up the full definition Resin tools combine most of the advantages of metal moulds with relative ease of manufacture Various resinous materials are commercially ava...

Страница 14: ...me cases painted the presence of release agent used to help free a tight moulding may make the surface resistant to further decoration Trimming An ideal moulding will be ready for use when removed fro...

Страница 15: ...es on mould Is mould restricting vacuum flow Are vacuum tracks in mould adequate Webbing small pleats at corners of mouldings Incorrect pre stretch height Adjust pre stretch flow and or time Check pan...

Страница 16: ...zoning Thick tops on finished mouldings Chill marks Mould too cold causing rapid cooling on contact Increase mould temperature Adjust flow on water cooled moulds Design of mould Use plug tool to assis...

Страница 17: ...ing elements contain a length of resistance wire internally which becomes extremely hot when electricity is applied The wire expands and contracts as it heats and cools Eventually due to the continual...

Страница 18: ...igue and require replacement Only the correct grade of cable should be used and the work carried out by a skilled technician The ceramic heating elements should be periodically inspected particularly...

Страница 19: ...tomatic sheet levelling system An optical sensor directs a beam of infrared light across the machine a honeycomb reflector receives this light and shines it back to the sensor If the beam is broken ai...

Страница 20: ...eals follow the procedure on page 21 Other causes of vacuum loss are loose or damaged flexible hose from table to metal pipe at back of machine blocked filters or build up of contamination in the vacu...

Страница 21: ...corroded If the heater has been left in the forward position with no plastic in the clamp frame the table will start to overheat The pipe attached to the back of the table will shrink and constrict t...

Страница 22: ...rdering any pneumatic spare parts The importance of filling the lubricator with oil on a daily basis cannot be over emphasised Adjust the lubricator such that a small amount of oil mist is visible in...

Страница 23: ...rips of silicon seal until it is firmly seated in to the sealant Do not attempt to stretch the seal strip it will contract back to its original size before the sealant sets Ensure the strips are strai...

Страница 24: ...us at the below address stating the model FM660 manual or power table the serial No on specification plate and a full description of the fault or parts you need 23 Formech International Limited Unit...

Страница 25: ...Zone 3 L2 to Zone 4 L3 to Zone 5 L3 to Zone 6 N Beam Sensor Blue 0V Brown 12V Black Signal System output PCB Multi function user inferface control panel IDC 20 Way IDC 20 Way Table Up Valve Coil optio...

Страница 26: ...se 2 x 4mm SIAFGL Three phase N Star 3 x 2 5mm Neutral 4mm SIAFGL Conduit Adaptaflex 20mmwith Swivels 700mm Cable chain 32 Links End Bracket Zone feeds 1 5mm SIAFGL Red Earth 2 5mm SIAFGL G Y Stud N 1...

Отзывы: