1. Locate the Allen tools supplied with the Cross Perforation kit.
2. Place the cross perforation tool on a table in the orientation shown below.
3. Remove one guide bolt [C] and spring [D]. Only one side needs to be removed.
WARNING!
All blades are very sharp: use extreme caution. Leather gloves must be worn
whenever handling the blades.
Anvil strip removal / replacement
D
C
A
B
Continued on next page...
NOTE:
Each anvil strip can be used
twice. When perforation is no
longer effective the anvil strip
can be rotated 180 degrees to be
reused.
NOTE:
Before replacing anvil strip decrease perforation depth to avoid causing excess strain
on motor and reducing lifespan of anvil strip. adjustment procedure can be found under