background image

23

CERTIFICATE OF ACCEPTANCE

Unit Type

Single-room reversible energy recovery ventilator

Model
Serial Number
Manufacture Date

Quality Inspector’s

Stamp

SELLER INFORMATION

Seller

Seller’s Stamp

Address
Phone Number
E-mail
Purchase Date

This is to certify acceptance of the complete unit delivery with the user’s manual. The warranty terms are 
acknowledged and accepted.

Customer’s Signature

INSTALLATION CERTIFICATE

The unit _____________________________________ is installed pursuant to the requirements stated 
in the present user's manual.

Installation Stamp

Company name
Address
Phone Number
Installation

Technician’s Full Name
Installation Date:

Signature:

The unit has been installed in accordance with the provisions of all the applicable local and national construction, 
electrical and technical codes and standards. The unit operates normally as intended by the manufacturer.

Signature:

WARRANTY CARD

Unit Type

Single-room reversible energy recovery ventilator

Seller’s Stamp

Model
Serial Number
Manufacture Date
Purchase Date
Warranty Period

Seller

Содержание TwinFresh Expert RA1-50 C1 V.3

Страница 1: ...TwinFresh Expert RA1 50V 3 TwinFresh Expert RA1 50 C1V 3 TwinFresh Expert RM1 50V 3 Single room reversible energy recovery ventilator USER S MANUAL...

Страница 2: ...al requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards must be observed when installing and operating the unit Dis...

Страница 3: ...tal capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety Children should be super...

Страница 4: ...sembly 1 pc Outer ventilation hood 1 pc Remote control 1 pc Cardboard mounting plate 1 pc Mounting kit 2 packages Foam wedges 1 kit User s manual 1 pc Mounting hood installation instruction 1 pc Packi...

Страница 5: ...from those described in this manual Technical specifications of the particular model are indicated on the unit casing The air duct length depends on the unit model refer to the Designation Key For th...

Страница 6: ...hood model Regenerator unit Provides heat recovery Fan unit Creates air flow Air duct Plastic air duct Sound absorbing material A layer of sound absorbing material for attenuation of noise generated d...

Страница 7: ...nd is heated up to the room temperature In 70 seconds as the ceramic regenerator gets cooled down the ventilator is switched to air extraction mode and the cycle is renewed If two ventilators are inst...

Страница 8: ...air duct in the wall and fix it with mounting foam The air duct end must protrude for the distance that enables installation of the outer ventilation hood see the User s manual for the outer ventilati...

Страница 9: ...o a required depth Route the power cable from the wall outside through the specially marked opening on the master plate 5 85 207 160 87 5 138 103 5 137 23 4 holes 4 Unlatch and detach the front part o...

Страница 10: ...xcess part of the sound absorbing material Insert the ready sound absorbing roll into the air duct Insert the wires under the retaining clip and connect the connector to the circuit board If the wall...

Страница 11: ...11 8 Install the front part of the indoor unit 10 Install the outer ventilation hood For this see the user s manual for the hood...

Страница 12: ...ce only The actual conductor cross section selection must be based on its type maximum permissible heating insulation length and installation method Use copper wires for all the electric connections E...

Страница 13: ...nd Out NO1 NO2 12V N L N L In Gnd Gnd Out NO1 NO2 12V N L N L In Gnd Gnd Out NO1 NO2 12V N L Power input 100 240 V 50 60 Hz to the next ventilator to the next ventilator to the next ventilator Ventila...

Страница 14: ...er external device the ventilator switches to higher speed After normalization of the indoor humidity level or any other air parameters the ventilator will switch to the previous mode after the set ti...

Страница 15: ...P switch no 8 on for at least 3 seconds and then turn it off Alarm Alarm indicator for emergency shutdown of the unit Permanent glowing of the Alarm indicator of the Master unit indicates an alarm in...

Страница 16: ...he unit functionality is not changed To open the air duct pull the front panel while holding the special recesses The fan starts operating according to the actual speed setting Air duct shut off Air d...

Страница 17: ...trol unit to take off the front part Please make sure the shutter actuator rod is in lower position during re installation of the front panel If the rod is up please wait for about 2 minutes until it...

Страница 18: ...once a year To reset the filter timer before installing the front part of the indoor unit back in place supply power to the ventilator using the circuit breaker then switch on the DIP switch no 8 for...

Страница 19: ...t casing or the outer ventilation hood Tighten the screws of the ventilator or the outer ventilation hood TROUBLESHOOTING STORAGE AND TRANSPORTATION REGULATIONS Store the unit in the manufacturer s or...

Страница 20: ...Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual includin...

Страница 21: ...21...

Страница 22: ...22 TwinFresh Expert RA M1 50 C1 V 3...

Страница 23: ...___________________________________ is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Na...

Страница 24: ...Foris252EN_A4_stkr 01...

Отзывы: