- 1 -
Rio-S
Installation manual
doc.
R24
doc.
R24
iss V1.1
RIO-S
installation manual
Double leaf 24V controller
Features
Soft start, soft stop
Self setting limits
Pressure sensitive reversal
Rolling code 25 remotes
Autoclose & interleaf delay
4 force settings
Specifications
Supply
230Vac 50/60Hz @ 5A
Motors
2x 24Vdc
Aux supply
24Vdc @ 1A
Housing
ABS IP44, 1.8kg
Dimensions
227 x 277 x 108mm
Receiver
433MHz rolling code
1.0 Description
Rio-S is a 24V panel for a light weight double leaf
swing gates. There are 2 PCBs and a transformer.
Space is reserved for backup batteries.
1.1 Inputs & outputs
The plug in control connector has 2 safety inputs
and 2 control inputs. Control inputs are normally
open active low, safety input are normally closed.
Open inputs are 5v. All return to common term C
The lock output ‘K’ & lamp output ‘L’ are relay
contacts switching to +24Vdc. Photobeam supply
‘B’ switches on when the motor is in motion to
conserve power when running on batteries.
Output B can be set to 12V or 24V depending on
the position of jumper link J1.
The DC lamp output includes a flasher circuit
1.2 Terminal functions
D1)
Full gate opening. Function selected on SW2
6OFF
- 4 step auto, open–stop-close-stop
6ON
- 2 step auto, open-close function
D2)
Pedestrian opning opens one leaf.
F1)
Re-opens the gate during closure. The gate re-
closes when the obstacle is removed and following
the normal delay or. No action during opening.
Delays close if active while open.
F2)
If activated during opening, the gate stops dead.
Stays still until next command. No response while
closing.
M-N)
Motor output. G is protective earth.
B)
Photobeam supply. On when gate is moving.
L)
24Vdc lamp or buzzer output. No flashing is
required because the switching is in controller.
K)
24Vdc lock output. Pulses the lock for
1 sec before the gate begins to open.
Con2)
12Vdc relay output to switch a 230Vac lamp.
Power board
power plug
DIP switches
Motor connectors
control connector
M1
M2
LOCK DCL - + - IR1 IR2 - DR1 DR2
1.3 DIP switches
SW2
8 way
DIP1
Interleaf delay 1 sec
DIP2
Interleaf delay 2 secs
both on for delay 3 secs
DIP3
--- not used ---
DIP4
OFF
, M1 opens first,
ON
M2 opens first
DIP5
OFF
for double leaf,
ON
for single leaf
DIP6
OFF
for 4 step auto,
ON
for 2 step auto.
DIP7
When
ON
, the gate must close fully before
a new open signal can be accepted.
DIP8
Setting limits (release and open fully), turn
DIP8 ON
,
use
ST
to close, release then press
ST
to open fully turn
DIP8 OFF
SW1
auto-close
delays add together
DIP1
+ 30 secs
DIP2
+ 60 secs
DIP3
+ 120 secs
DIP4
code enable