Forematic RIO-S Скачать руководство пользователя страница 1

 

 

                                         - 1 - 

    Rio-S          

Installation manual                    

doc. 

R24

 

 
 
 

 
 
 
 

    

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

doc. 

R24 

      iss V1.1

 

 

RIO-S 

 installation manual           

 

 

 

Double leaf 24V controller 

 

    Features 

 

 

Soft start, soft stop

 

 

Self setting limits

 

 

Pressure sensitive reversal

 

 

Rolling code 25 remotes

 

 

Autoclose & interleaf delay

 

 

4 force settings

 

 

 

Specifications 

 

Supply

  

 

230Vac 50/60Hz @ 5A  

Motors

  

 

2x 24Vdc  

Aux supply

  

24Vdc @ 1A  

Housing

 

 

ABS IP44, 1.8kg 

Dimensions 

227 x 277 x 108mm 

Receiver

 

 

433MHz rolling code 

 

 

 

  1.0   Description 

 

Rio-S is a 24V panel for a light weight double leaf 
swing gates. There are 2 PCBs and a transformer. 
Space is reserved for backup batteries.  
 
 

  1.1   Inputs & outputs 

 

The plug in control connector has 2 safety inputs 
and 2 control inputs. Control inputs are normally 
open active low, safety input are normally closed. 
Open inputs are 5v.  All return to common term C 

 

The  lock  output  ‘K’  &  lamp  output  ‘L’  are  relay 
contacts switching to +24Vdc. Photobeam supply 
‘B’  switches  on  when  the  motor  is  in  motion  to 
conserve  power  when  running  on  batteries. 
Output B can be set to 12V or 24V depending on 
the position of jumper link J1.  

The DC lamp output includes a flasher circuit 

  1.2   Terminal functions 

 

D1)

   

Full gate opening. Function selected on SW2 

 

  

6OFF

 -  4 step auto, open–stop-close-stop  

 

  

6ON

  -   2 step auto, open-close function 

 

D2)

   

Pedestrian opning opens one leaf.   

 

F1) 

Re-opens the gate during closure. The gate re-
closes when the obstacle is removed and following 
the normal delay or. No action during opening. 
Delays close if active while open. 

 

F2) 

If activated during opening, the gate stops dead. 
Stays still until next command. No response while 
closing. 

 

M-N)

  Motor output. G is protective earth. 

 

B)

   

Photobeam supply. On when gate is moving. 

 

L) 

 

24Vdc lamp or buzzer output. No flashing is 
required because the switching is in controller. 

 

K)

   

24Vdc lock output. Pulses the lock for  
1 sec before the gate begins to open. 

 

Con2) 

12Vdc relay output to switch a 230Vac lamp.  

 

 

 

Power board  

 

  power plug   

 

 

          DIP switches 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 Motor connectors   

 

 control connector 

M1 

M2 

 

 

LOCK   DCL   -      +      -      IR1  IR2   -    DR1  DR2 

  1.3   DIP switches 

              

SW2 

8 way

 

DIP1

  

Interleaf delay 1 sec

 

DIP2

  

Interleaf delay 2 secs

 

both on for delay 3 secs

 

DIP3

  

--- not used ---

 

DIP4

  

OFF

 

, M1 opens first,

 

ON

 

M2 opens first

 

DIP5

  

OFF

 

for double leaf,

 

ON

 

for single leaf

 

DIP6

  

OFF

 

for 4 step auto,

 

ON

 

for 2 step auto.

 

DIP7

  

When 

ON

, the gate must close fully before

 

a new open signal can be accepted.  

DIP8

  

Setting limits (release and open fully), turn 

DIP8 ON

 use 

ST 

to close, release then press 

ST

 to open fully turn 

DIP8 OFF

 

 
 
 

 
 

 

SW1

  auto-close 

delays add together 

 

DIP1

 

  + 30 secs

 

DIP2

 

  + 60 secs

 

DIP3

 

  + 120 secs

 

DIP4

 

  code enable

 

Отзывы: