background image

 

 

                                         - 1 - 

    Rio-R          

Installation manual                    

doc. 

R12

 

 
 
 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

doc. 

R12 

      iss V1.2

 

 

RIO-R 

 installation manual           

 

Contents 

 

 

Description 

 

Technical characteristics 

 

Safety warnings 

 

User instructions 

 

Barrier arm options 

 

Dimensions & layout 

 

Installation 

 

Controller description 

 

Functions inputs & outputs 

 

Accessory description 

 

Wiring 

 

 

 

Double leaf 

gate control 

panel 

   Specifications

 

 

Supply

  

 

230Vac 50/60Hz @ 5A  

Motors

  

 

2x 100W ACIM’s  

Aux supply

 

24Vdc @ 1A  

Housing

 

 

ABS IP44, 1.8kg 

Dimensions 

 

227 x 277 x 108mm 

Receiver

   

433MHz rolling code 

 

 

  60 rolling code remote capacity 
  Auto-close 10s to 7mins 
  Single or double leaf 
  Soft stop, optional soft start 
  Interleaf delay  0 

– 9s 

  4 force settings 
  Pressure sensitive reversal 
  Auto run time setting  

 

 

 

 

         Transformer    

 

 

 

 

Display     

Accessory header 

            connector   

  

 

 

 

 

 

 

 

 

 

 

 

 

         +     -    P

 

 

            Main   

 

 

     

 

 

 

 

 

Code   

 

  Buttons 

             Fuse 
 
 
 
 
 
 
 
          230Vac supply      motor wiring         control wiring     lock wiring

 

Motor 1

   

1-2-3

  - 

1 neutral, 2 open live, 3 close live

 

Motor 2 

 

4-5-6

  - 

4 neutral, 5 open live, 6 close live

 

AC lamp 

 

7-8

  

7 neutral, 8 lamp live during motion

 

 

Open button

 

9-10

 

9 input, 10 com (-ve)

 

Pedestrian 

11-12

  - 

11 input, 12 com (-ve)

 

Safety 2   

13-15

  - 

11 input, 12 com (-ve)

 

Safety 1   

14-15

  - 

11 input, 12 com (-ve)

 

Stop button

 

16-17

  - 

16 input, 17 com (-ve)

 

 

DC lamp

   

18-20 

18 (+24v), 20 switch to gnd

 

DC lock

   

19-21

  - 

19 (+24v), 21 switch to gnd

 

1.0  Description 

 

RIO-R panel is for AC induction motors with limit switches. 
For single or double leaf gates / doors.  Programming is 
with navigation buttons and an LCD display.  
 

1.1  Inputs & outputs 

 

RIO-R supports two command inputs and two safety inputs.  
Inputs have +5V pull ups, switching to ground. Command 
inputs are active low. Safety inputs are N/C normally low.  

 

Solid state switching outputs are provided for an electric 
lock that operates for 1sec on opening. A solid state 24Vdc 
flashing light output switches at 1Hz. An accessory header  
is provided for powered external trigger devices such as  a 
keypad, loop detector, exit device, or access control device. 
 

1.2  Input functions 

 

SBS input 

  Open 

– stop-close-stop function. When stopped 

during open the gate re-closes after auto-close delay. W hen 
stopped during closing, gate waits for next command. 

 

Ped input

 Same function as SBS input, but on one gate. 

 

Safety 1 

Re-opens the gate during closure. Assuming the 

danger is removed, the gate re-closes after normal delay. 
No action during opening. Delays close if active while open.  

 

Safety 2

  If activated during opening, the gate stops dead. 

Stays still until next command. No response while closing. 

 

Stop   

During opening, stops, then re-closes after 

normal auto-close delay. Stops during closing. 
 

 

Wiring assumes motors include capacitors & limit switches 

DC lamp does not need a flasher 

M1 

M2 

 

W

   

U

    

V

    

W

    

X

    

Y

   

W

   

L

a

               

D

     

C

     

P

    

C

  

F

2

   

F

1

  

C

    

E

     

C

    

A

    

A

      

L

d

 

   

Display 

 

In normal running, the left digit shows the 
state of inputs. Black is active. You should 
have three black horizontal bars.  

 

   F1  =    IR1 
   E    =   Stop

 

   F2  =   IR2 
   D    =   Door 
   P    =   Ped

 

 
 

Right digit segments rotate anti-clockwise 
During normal running. Both digits show 
alpha numeric digits during programming. 

 

Отзывы: