HYBRID COMPONENT LOCATION AND IDENTIFICATION - CONTINUED

COMPONENT

LOCATION / DESCRIPTION

FUNCTION

1

High-Voltage

• Located behind the rear

Provides means to disconnect

Service  Disconnect

seatback.

high-voltage battery for safely
servicing vehicle.

• Orange rectangle with a molded

plastic handle, about 100 mm
(4 in) in length.

2

High-Voltage Battery

• Located behind the rear

Provides high-voltage storage

Approximately 300

seatback.                                       for vehicle’s electric motor.

Volts DC

• Sealed nickel-metal hydride.

3

High-Voltage Wiring

• Runs along the vehicle’s

Provides physical connection

floorpan from the high-voltage      

 

 between High-Voltage battery

battery to the Electronically            and vehicle’s High-Voltage
Controlled Continuously                 equipment.
Variable Transaxle (ECVT),
to the DC-to-DC converter,
then the electric A/C unit.

• All high-voltage wiring has

orange-colored insulation.

4

12-Volt Battery

• Located under the hood on the

Provides 12-volts for vehicle

driver side of the vehicle.

accessories.

• Typical automotive 6-cell

lead/acid design.

5

Electronically

• Transverse-mounted design,

Provides rotational force to

Controlled

similar to the non-Hybrid

wheels for vehicle propulsion,

Continuously

Fusion MKZ vehicles.

generates electricity to

Variable Transaxle

recharge batteries during

(ECVT)

• Contains the traction motor,

operation and contains some

generator motor and hybrid          

 

electronics.

electronics.

6

DC/DC  Converter

• Located under the hood on

Provides 12 volts to charge

the passenger side, forward

the 12-volt battery and

of the strut tower.

run vehicle accessories.

• It has orange high voltage wires

and Motor Electronics Cooling
System hoses attached to it.

7

Electric A/C

• Located in front of

Provides electric A/C operation;

Compressor

the engine.                                     replaces the belt driven A/C

• It has an orange high voltage

compressor.

wire attached to it using an
interlock connector.

Содержание Fusion hybrid 2012

Страница 1: ...FCS 15129 12 08 2011 EMERGENCY RESPONSE GUIDE FUSION HYBRID MKZ HYBRID 2012...

Страница 2: ...rmance with a 4 cylinder engine and electric motor reduced emissions and improved fuel economy The high voltage system is self contained never needing to be plugged into an electrical outlet for recha...

Страница 3: ...vehicles can easily be identified by the Hybrid badges located on the left and right front doors There is a Hybrid nameplate on the trunk lid that also includes the green leaf blue highway Hybrid ico...

Страница 4: ...CLE The Fusion Hybrid and MKZ Hybrid vehicles have a unique engine appearance cover with a raised HYBRID icon on it The 5th 6th and 7th digits of the Vehicle Identification Number VIN identify the Hyb...

Страница 5: ...d the high voltage interlock circuit opens and disables the high voltage system Ignition Key in the OFF Position Any time the ignition lock cylinder is in the OFF position the high voltage system is d...

Страница 6: ...MKZ Hybrid Emergency Response Guide 08 2011 5 HIGH VOLTAGE WARNING DECALS On Hybrid vehicles WARNING decals are located on components in the high voltage system throughout the vehicle Please see exam...

Страница 7: ...ND IDENTIFICATION The illustration below and its defining chart on Page 7 provide the location description and basic function of the Hybrid system components NOTE All high voltage wires and harnesses...

Страница 8: ...tric A C unit All high voltage wiring has orange colored insulation 4 12 Volt Battery Located under the hood on the Provides 12 volts for vehicle driver side of the vehicle accessories Typical automot...

Страница 9: ...vice disconnect will disconnect the high voltage from the vehicle The battery pack will remain live and dangerous The total voltage of the battery pack is approximately 300 volts DC The battery case i...

Страница 10: ...ubber or Nitrile an apron or overcoat suitable to protect against alkaline and rubber boots are required when handling damaged batteries Fold down helmet shields are not acceptable for acid or alkalin...

Страница 11: ...ld insulated boots protective raincoat and apron Bring the following equipment ClassABC powder type fire extinguisher A nonconductive object about 1 5 m 5 ft long This can be used to safely push someo...

Страница 12: ...oltage battery is completely discharged A submerged high voltage battery may produce a fizzing or bubbling reaction to the water The high voltage battery will be discharged when the fizzing or bubblin...