Generator
www.fordpower.cc
OPERATOR’S MANUAL
MODEL#: FG
62
50
P
ITEM#: F2E52
5R
991
Страница 1: ...Generator www fordpower cc OPERATOR S MANUAL MODEL FG6250P ITEM F2E525R991...
Страница 2: ...nnecting Generator to an Electrical System 12 Operation 14 How to Start Engine 14 Grounding the Generator 14 How to Stop Engine 14 Receptacles and Extension Cords 14 Don t Overload Generator 15 Wattag...
Страница 3: ...ions To order parts receive warranty assistance or other services inquiries you can contact us by internet at www fordpower cc The emissions control system for this generator is compliant with all sta...
Страница 4: ...serious injury avoid attempting to lift the generator alone WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cau...
Страница 5: ...If unit has been running then the fuel cap is under pressure remove slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the...
Страница 6: ...nerator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground source WARNING Generator must be properly grounded to prevent electrocution Never handle the...
Страница 7: ...tch B Main Circuit Breaker C Hour Meter D Circuit Protectors E A B C D E Two 120 V GFCI duplex Receptacles 120 240 Volt AC 30 Amp twist lock receptacle NEMA L14 30 120 Volt AC 30 Amp twist lock recept...
Страница 8: ...hoke Lever L Air Filter M Handles Grips N Oil Drain Plug O Support Leg Foot P Fuel Tank Q Fuel Fill Cap R Fuel Valve ON OFF T Oil Fill Dipstick U No Flat Foam Filled Tires H J K L M N O P Q R S T S Re...
Страница 9: ...g the generator 4 Leave generator on box to install wheel assembly Packing List Check all loose parts to the following list Contact your dealer if any loose parts are not included Description Qty Gene...
Страница 10: ...ping screws Raise or tilt generator so you can slide the wheel axle pin into the wheel the washer the wheel mounting hole located on the side of the frame Secure the wheel assembly by reinserting a ha...
Страница 11: ...urface wipe dipstick clean then reinsert dipstick without rethreading Adding Checking Engine Oil See fig 6 You must add oil before first operating this generator Always check oil level before each ope...
Страница 12: ...r back up power notify the utility company If connecting generator to a building s electrical system for standby power you must use a qualified electrician to install a transfer switch Failure to isol...
Страница 13: ...the choke is fully slid to the RUN position See fig 12 How to Start Engine See fig 9 12 Slide the choke lever to the Choke position See fig 10 SKIP THIS IF THE ENGINE IS WARM OR HOT Fig 9 Fig 11 Recoi...
Страница 14: ...d extension cord How to Stop Engine See fig 13 15 Fig 13 Fig 14 Fig 15 2 This generator is equipped with the following receptacles 120 Volt AC 20 Amp receptacle Two 120 Volt AC 20 Amp duplex 120 240 V...
Страница 15: ...nd surge watts for all electronic devices connected to the generator Rated watts refer to the power a generator must supply to keep a device running Surge watts refer to the power a generator must sup...
Страница 16: ...0 2000 Electric Drill HP 5 4 Amps 600 900 Hammer Drill 1000 3000 Air Compressor 1600 4500 Other Home Security System 500 500 Garage Door Opener HP 750 750 Essentials Rated Watts Surge Watts 75W Light...
Страница 17: ...o prevent icing take the following steps 1 Replace any old fuel with clean fresh fuel 2 Use synthetic 5W 30 or SAE 5W 30 engine oil Check oil daily or after every 8 hours of use 3 Turn fuel valve to t...
Страница 18: ...Store unit in a clean and dry area WARNING After First 5 Hours Change Oil After 8 Hours or Daily Clean Debris Check Engine Oil Level Annually 25 hr Use Check and Clean Air Cleaner Change Engine Oil S...
Страница 19: ...res determine the proper oil viscosity for the engine Use the chart to select the best viscosity for the outdoor temperature range expected Carefully add SAE 10W 30 to empty reservoir until the oil re...
Страница 20: ...Equivalent To clean remove the air filter cover Carefully pull the air filter out by lifting up along the edges Remove dirt from filter by tapping on it or having it blown out Replace with new filter...
Страница 21: ...empty if needed or inspect filter prior to fill up CAUTION Draining Fuel Tank and Carburetor To help prevent gum deposits in the fuel system drain the fuel from the tank and carburetor before storing...
Страница 22: ...stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system and carburetor Store the generator indoors to prevent freezing The generator must be Shipped Run and Stored in th...
Страница 23: ...er in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compression 14 Dead battery 15 Engine has flooded...
Страница 24: ...DIAGRAMS 24 FG6250P Recoil Start Wiring Diagram...
Страница 25: ...coverage on generator engine and alternator components parts only 24 Month Limited coverage on generator engine components parts only Personal use means personal residential household use or recreati...
Страница 26: ...l the original receipt and product to the address found on the web site if purchased on line You can also locate your nearest Ford Power Equipment dealer for service or warranty questions by calling t...