Generator
www.fordpower.cc
OPERATOR’S MANUAL
MODEL#: FG
4
6
50
P
ITEM#: F2E
360
R
991
Warning: The Engine Exhaust from this product contains chemicals known to
the State of California to cause cancer, birth defects or other reproductive harm.
Страница 1: ... fordpower cc OPERATOR S MANUAL MODEL FG4650P ITEM F2E360R991 Warning The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm ...
Страница 2: ...1 Adding Fuel 11 Connecting Generator to an Electrical System 12 Operation 13 How to Start Engine 14 Grounding the Generator 13 How to Stop Engine 14 Receptacles and Extension Cords 14 Don t Overload Generator 16 Wattage Reference Guide 16 Cold Weather Operation 17 Maintenance 18 Maintenance Schedule 18 Engine Maintenance 18 Changing Oil 19 Maintaining Fuel Valve 21 How to Store 22 Troubleshooting...
Страница 3: ...fications To order parts receive warranty assistance or other services inquiries you can contact us by internet at www fordpower cc The emissions control system for this generator is compliant with all standards set by the U S Agency AC Output Rated Wattage 3600W 3 6kW Rated Voltage 120V 240V Rated Frequency 60Hz Rated Ampere 30A 15A Rated Output 3 6kVA Maximum Output 4 65kVA Record the following ...
Страница 4: ...f serious injury avoid attempting to lift the generator alone WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cause headache confusion fatigue nausea fainting Never use indoors in a covered area or in a confined space even if doors and windows are open Keep exhaust from this unit from entering a confined area t...
Страница 5: ... If unit has been running then the fuel cap is under pressure remove slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the spark plug wire and make sure the fuel tank is empty with the fuel shutoff valve turned to the off position WARNING Never exceed generator s wattage amperage capacity This could damage the generator...
Страница 6: ...enerator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground source WARNING Generator must be properly grounded to prevent electrocution Never handle the generator electronic devices or any cord while standing in water while barefoot or when hands or feet are wet Always keep the generator dry Never operate generator in rain or under wet conditions Us...
Страница 7: ...ain Circuit Breaker C Circuit Protector D Voltage Selector Switch A B E E Hour Meter F 120 240 Volt AC 30 Amp twist lock receptacle NEMA L14 30 G 120 V duplex Receptacle NEMA 5 20R H 120 Volt AC 30 Amp RV receptacle TT 30 F G C D H ...
Страница 8: ...nt K Generator Frame L Choke Lever M Air Filter N Handles Grips O Oil Drain Plug P Support Leg Foot Q Fuel Tank R Fuel Fill Cap S Fuel Valve ON OFF U Oil Fill Dipstick V No Flat Foam Filled Tires J Q T Recoil Starter Grip U I L M N K P S T V O R ...
Страница 9: ...the generator 4 Leave generator on box to install wheel assembly Packing List Check all loose parts to the following list Contact your dealer if any loose parts are not included Description Qty Generator 1 Quick Start Guide 1 4 Cycle engine oil SAE10W 30 Toolkit Spark Plug Wrench Phillips Philips Screwdriver Combination Wrench 1 1 1 2 1 Washer 2 M8 x 16mm Hex Bolts for Foot 2 Funnel 1 10W30 OIL Ha...
Страница 10: ...pping screws Raise or tilt generator so you can slide the wheel axle pin into the wheel the washer the wheel mounting hole located on the side of the frame Secure the wheel assembly by reinserting a hair pin through hole at the end of the wheel axle and pressing until it locks into place Install hub cap to the wheel until Click Install self tapping screw until the screw is snug Repeat process on t...
Страница 11: ...surface wipe dipstick clean then reinsert dipstick without rethreading Adding Checking Engine Oil See fig 6 You must add oil before first operating this generator Always check oil level before each operation DO NOT USE E15 OR E85 FUEL IN THIS UNIT IT IS A VIOLATION OF FEDERAL LAW AND WILL DAMAGE THE UNIT AND VOID YOUR WARRANTY CAUTION Set generator on a clean and level surface in an area that is w...
Страница 12: ...or back up power notify the utility company If connecting generator to a building s electrical system for standby power you must use a qualified electrician to install a transfer switch Failure to isolate the generator from the power utility could result in serious injury or death to electric utility workers WARNING This generator produces a very high voltage which could result in burn or electroc...
Страница 13: ...on See fig 12 How to Start Engine See fig 9 12 choke lever to the Choke position See fig 10 SKIP THIS IF THE ENGINE IS WARM OR HOT Fig 9 Fig 11 Recoil Start Fig 12 CHOKE RUN CHOKE LEVER CHOKE RUN CHOKE LEVER WAIT 5sec Fig 10 SKIP THIS IF THE ENGINE IS WARM OR HOT The ground terminal located on the back of the generator frame must always be used to connect generator to a driven ground rod Connect t...
Страница 14: ...high quality well insulated grounded extension cords in good condition with generator receptacles Follow each load manufacturer s power rating recommendation when selecting receptacle and extension cord How to Stop Engine See fig 13 15 Fig 13 Fig 14 Fig 15 This generator is equipped with the following receptacles 120 Volt AC 20 Amp receptacle 120 Volt AC 20 Amp duplex Receptacles NEMA 5 20R 120 24...
Страница 15: ... to the below table to ensure the extension cord used has the capacity to carry the required load If the size of the cable is inadequate it can cause a voltage drop which can damage the electrical device and cord Current Amps Load Watts Maximum Cord Length 230V 8 Wire 10 Wire 12 Wire 14 Wire 16 Wire 2 5 600 X 1000 ft 600 ft 375 ft 250 ft 5 1200 X 500 ft 300 ft 200 ft 125 ft 7 5 1800 X 350 ft 200 f...
Страница 16: ...s Surge Watts 75W Light Bulbs 75 each 75 each 18 CU Ft Refrigerator Freezer 800 2200 Furnace Fan HP 800 2350 Sump Pump HP 1000 2000 Water Pump HP 1000 3000 Heating Cooling 650 800 Table Fan Dehumidifier 800 2000 Window AC 10k BTU 1200 3600 Central Air 10k BTU 1500 6000 Electric Blanket 400 400 Space Heater 1800 1800 Kitchen Blender 300 900 Toaster 2 slice 1000 1600 Coffee Maker 1500 1500 Electric ...
Страница 17: ...oil See page 19 Check oil daily or after every 8 hours of use 3 Turn fuel valve to the open position 4 Ensure generator is serviced according to the maintenance schedule under Maintenance section of manual 5 Shelter unit from elements OPERATION 17 Fig 16 Hour Meter See Fig 16 The digital hour meter operates whenever the engine is running and keeps track of how many hours the unit has been used Use...
Страница 18: ...e Store unit in a clean and dry area WARNING After First 5 Hours Change Oil After 8 Hours or Daily Clean Debris Check Engine Oil Level Annually 25 hr Use Check and Clean Air Cleaner Change Engine Oil Service more often under dirty or dusty conditions Check Muffler and Spark Arrester Annually 100 hr Use Service Spark Plug Replace with NGK BP6ES Champion N9YC or equivalent Service Fuel Valve Inspect...
Страница 19: ...ures determine the proper oil viscosity for the engine Use the chart to select the best viscosity for the outdoor temperature range expected Carefully add SAE 10W 30 to empty reservoir until the oil reaches the outer edge of the oil fill hole Crankcase Dipstick hole Replace crankcase dipstick Oil drainage plug Fig 17 Oil Fill Dipstick 22 4 14 32 50 68 86 104 30 20 10 0 10 20 30 40 SAE 30 10W 30 Sy...
Страница 20: ...r Equivalent To clean remove the air filter cover Carefully pull the air filter out by lifting up along the edges Remove dirt from filter by tapping on it or having it blown out Replace with new filter annually Reinstall air filter so that it seals and replace air filter cover A dirty air filter will reduce the life span of the engine make it difficult to start the engine and reduce the unit s per...
Страница 21: ... empty if needed or inspect filter prior to fill up CAUTION Draining Fuel Tank and Carburetor To help prevent gum deposits in the fuel system drain the fuel from the tank and carburetor before storing the unit for long periods of time This will help prevent starting problems in the future If the unit is stored with fuel and the fuel becomes stale or turns gummy or to varnish the warranty does not ...
Страница 22: ... stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system and carburetor Store the generator indoors to prevent freezing The generator must be Shipped Run and Stored in the upright position as seen in this image For short term storage start generator once every 7 days Inspect air cooling slots Remove any debris if obstructed Engine Long Term Storage Remove the spark p...
Страница 23: ...g 6 Bad spark plug 7 Water in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compression 14 Engine has flooded 1 Turn switch to ON 2 Replace Air filter 3 Clean or replace fuel filter 4 Replace fuel 5 Reconnect spark plug wire 6 Replace spark plug 7 Drain fuel tank and replace fuel 8 Turn fuel valve to...
Страница 24: ...DIAGRAMS 24 ...
Страница 25: ...d coverage on generator engine and alternator components parts only 24 Month Limited coverage on generator engine components parts only Personal use means personal residential household use or recreational use by the retail consumer Commercial use means all other uses including commercial construction or other income producing purposes Once a generator has been used for commercial purposes it shal...
Страница 26: ...il the original receipt and product to the address found on the web site if purchased on line You can also locate your nearest Ford Power Equipment dealer for service or warranty questions by calling toll free at 1 888 863 7589 Ford Power Equipment recommends you retain all of your receipts covering the purchase and maintenance of your Portable Generator but will not deny you warranty coverage as ...