7. About SNMP
The USF-1053DDA can be remotely monitored using an external SNMP monitoring system that
supports SNMPv2C. MIB (Management Information Base) files that are required for SNMP monitoring
systems can be downloaded from the Web GUI. Refer to the prior section for details on downloading
MIB files. Refer to the USF frame operation manual for details on SNMP settings.
GET List
Object
group
Item Name
Object name in MIB file
Value
OID
Type
TRAP
Function
OID: 1.3.6.1.4.1.20175.1.312.1.
Unit
Status
Product Name
usf1053DdaProductName
USF-1053DDA
1
OCTET STRING
Product Code
usf1053DdaProductCode
1023808
2
INTEGER
Serial Number
usf1053DdaSerialNumber
1595****
3
INTEGER
Soft Version
usf1053DdaVersion
**.**
4
OCTET STRING
Slot Number
usf1053DdaSlotNumber
1
~
12
5
INTEGER
CPU Temperature
usf1053DdaCpuTemperature
** degree
Celsius
6
INTEGER
Input Video Status
usf1053DdaInputStatus
-1:cannotDetect
0: not Detected
1: detected
7
INTEGER
Input SDI Bit Rate
usf1053DdaSdiRate
-1:cannotDetect
0: not Detected
1: sdi SD
2: sdi HD
3: sdi 3G
8
INTEGER
Reclock Bypass
Setting
usf1053DdaReclockBypass
0:reclocking
1:reclock Bypass
9
INTEGER
* No item can be set from SNMP.
TRAP List
Object
Group
Item Name
Object name in MIB file
OID
Reference Object
Type
OID: 1.3.6.1.4.1.20175.1.312.0.
TRAP
SDI Input
usf1053DdaInputStatusChanged
1
usf1053DdaSlotNumber
INTEGER
usf1053DdaInputStatus
INTEGER
* When video signals routed from USF frame internal bus are distributed, SDI Input trap is not sent out.