27
6-4. LTC Menu
See section 7-2. "TIME CODE Processing" for details on time code processing.
6-4-1. LTC MUX
Parameter
Default
Description
LTC MUX
Through
Passes through or changes ANC time code data in the SDI
output.
Through
Passes through ANC data in SDI input without
modification.
MUX
Overwrites ANC data with the LTC selected under
LTC SEL below.
6-4-2. LTC SEL
Parameter
Default
Description
LTC SEL
AES
Selects LTC (time code) data to be embedded into the SDI
output.
AES
Uses the time code data of AES CH7/8 input for
SDI output.
Analog
Uses the time code data input from the
UFM-30MUX AI for SDI output.
* Time code input for AES CH7/8 can be selected on the front panel. (See section 2-1.
6-5. System Menu
6-5-1. SDI BYPASS
Parameter
Default
Description
SDI BYPS
Operate
Selects whether the SDI input is processed or bypassed when
powered On.
Basically, the SDI input signal is directly sent to the SDI output
via relay when powered Off.
Operate
Processes and sends the SDI input signal to the
SDI output.
Bypass
Directly sends the SDI input to the SDI output via
relay.
6-5-2. SDI LOCK MODE
Parameter
Default
Description
SDI Lock
Auto
Selects the Auto Detect or Specified TV standard for SDI
signals.
Auto
Automatically detects and sets the SDI TV
standard. If the SDI input signal is abnormal, the
standard set under
Format
(see the next
parameter) is applied.
Internal
Forcibly applies the TV standard set under
Format
to SDI signals.
USO
RESTRITO
Содержание UFM-30MUX
Страница 38: ...38 10 2 External Dimensions 10 2 1 UFM 30MUX All dimensions in mm USO RESTRITO...
Страница 39: ...39 10 2 2 UFM 3MUXAI All dimensions in mm USO RESTRITO...