141
15-6. Loading an Event at Start-up
The settings made for the background and key buses on the control panel are cleared when
powering off the switcher. You can, however, recall the desired panel setup whenever the
switcher starts by setting in the [SETUP - SYSTEM - INIT] menu as shown in the procedure
below.
(1) Press MENU in the SELECT/KEYPAD block.
(2) Press SETUP to display the SETUP menu top page.
(3) Turn F1 to select SYSTEM and then press F1.
SETUP :>
SYSTEM
>INPUT >OUTPUT >PANEL
MENU :>GPI/TLY >FUNCTION>EXT I/F >STATUS
(4) The [SETUP - SYSTEM] menu as shown below appears. Turn F1 to select INIT and then
press F1 to display the [SETUP - SYSTEM - INIT] menu.
SETUP :>FORMAT >REF I/O >ARCNET >ETHERNET
SYSTEM :>RS-422 >TIME >
INIT
>REBOOT
(5) Turn F3 to select the desired panel setup in the table below
SYSTEM : INIT : LOAD : : 1/1
INIT : >CURRENT : =
LAST
: :
LOAD setting
Description
OFF
The switcher starts with Last Saved Settings.
"Last Saved Settings" are automatically saved when the unit is
rebooted or SETUP is pressed.
See section 4-4. "How to Back up Settings."
LAST
The switcher starts with the last loaded event.
Note that to enable the Last Load function, an event must be
loaded after setting to LAST.
0-99
The switcher starts with a selected event (0-99) loaded.