140
15-5. Transitions Using Event Recall
The RATE parameter in the EVENT menu allows users to set the duration time (transition rate)
for loading events. With this duration time, two images before and after recalling events that
appear on program screens are automatically interpolated to create a smooth transition. The
RATE setting is made while storing events. It can also be set and changed before events are
recalled.
Operation Example
The following operation example shows an event that is saved to EVENT No. 10 with 150
frames for RATE and it is recalled while changing RATE to 30 frames.
Saving the Event
(1) Press EVENT in the SELECT/KEYPAD block to display the [EVENT MEMORY] menu.
(2) Turn F1 to select PAGE 1 (EVENT 10-19).
EVENT : PAGE :DIRECT :PAGECLR: RATE : 1/2
MEMORY : =
1
: =OFF : >CRNT : =OFF : L=0
(3) Press STORE to display the [EVENT STORE] menu.
(4) Press F4, enter 150 in the keypad, then press ENTER.
EVENT :SELECT : XPT : DATA : RATE : 1/2
STORE : =ALL : =ON : =ON : =
150
:P.01
Note that if setting RATE to 150 in the [EVENT MEMORY] menu, the initial value for
RATE in the [EVENT STORE] menu will
always be
150 (the default value).
(5) Press 0 in the keypad to save the current panel status to EVENT 10.
Loading the Event
(1) Press EVENT in the SELECT/KEYPAD block to display the [EVENT MEMORY] menu.
(2) Turn F1 to select PAGE 1 (EVENT 10-19).
(3) Press 0 in the keypad to recall EVENT 10. The [EVENT RECALL] menu will be displayed.
(4) Turn F4 to change
RATE
from 150 to 30.
EVENT :SELECT :XPT :DATA : RATE : 1/2
RECALL : =ALL : =ON : =ON : =
30
:P.01
(5) Press RECALL. The EVENT 10 settings are loaded to the control panel, taking 30 frames.
Loading is complete
Loading starts
PGM image
PGM image
Duration time set at RATE