137
15-3. Protecting / Deleting Event Data
This chapter sets write protection on EVENT 12 as an example. The data can be deleted from
EVENT 12 in the same menu page.
(1) Press EVENT in the SELECT/KEYPAD block to display the [EVENT MEMORY] menu.
(2) Select 1 (PAGE 1) in the [EVENT MEMORY] menu.
(Set
DIRECT
to OFF, so that EVENT 12 is not recalled when pressing the button.)
(3) Press 2 on the keypad. The [EVENT RECALL] menu will appear.
(4) Go to PAGE 3.
(5) Turn F2 to change
OVER WR
to DISBL(disable) to set write protection on EVENT 12.
EVENT :OVER WR:DELETE : : 3/3
RECALL : =
DISBL
: >OFF : :P.01
To delete data from
EVENT 12
, turn F2 to set DELETE to ON, then press F2.
EVENT :OVER WR:DELETE : : 3/3
RECALL : =OFF : >
ON
: :P.01
To Delete Data for an Event Page:
(1) Press EVENT in the SELECT/KEYPAD block to display the [EVENT MEMORY] menu.
(2) Turn F1 to select an event page to be deleted.
(3) Turn F3 to set
PAGECLR
to CRNT (current), then press F3. The data saved in the event
page will then be cleared.
EVENT : PAGE :DIRECT :PAGECLR: RATE : 1/2
MEMORY : =
1
: =OFF : >
CRNT
: =OFF :L=10
To Delete All Event Data :
(1) Press EVENT in the SELECT/KEYPAD block to display the [EVENT MEMORY] menu.
(2) Set
PAGECLR
to ALL, and press F3. All event data is cleared.
EVENT : PAGE :DIRECT :PAGECLR: RATE : 1/2
MEMORY : =0 : =OFF : >
ALL
: =OFF :L=10