Installation
Installing U155 dispenser in counter
1. Check that dispenser location meets all requirements in this manual and cut counter as shown.
2. Block up area below counter cut-out to support dispenser when lowered into place.
3. For automatic load dispensers, disconnect ice transport tube from bracket in storage area of dispenser.
(Since this tube must be reinstalled in bracket after dispenser is dropped into counter, note how tube is held
by bracket tabs before disconnecting.)
4. Carefully lower dispenser into counter until it rests on support blocks.
5. Adjust height from below until dispenser flange rests flush with counter.
6. Apply a bead approximately 1/4" (6mm) in diameter of NSF listed silicone sealant (Dow-Corning RTV-732
or equivalent) around perimeter of dispenser where it meets counter and smooth sealant to a 1/8" (4mm)
radius.
7. Install a hard drain line, maintaining at least a 1/4" per foot (20mm per 1m) slope, and insulate line to
prevent condensation.
8. Make electrical connections in accordance with applicable wiring diagrams provided, as well as NEC and
local codes. Provide disconnects within 10 ft (3m) of dispenser and icemaker for servicing.
26.25"
Front of counter
+.125"
- .125"
+ .125"
- .125"
30.375"
(772mm)
+3 mm
- 3 mm
(667mm)
+3 mm
- 3 mm
Counter cut-out
All U155 dispensers must be installed level in both directions and supported from
below with 6" - 9" (153 – 229mm) adjustable leg accessory provided, or channels
installed on site. DO NOT hang dispenser on flange.
!
PVC pipe is suggested. Care must be taken in sweating any metal drain pipe
used. Excessive heat applied while sweating metal pipe may melt plastic fitting on
dispenser.
!