User Guide

www.focusrite.com

v1.0

Содержание RedNet D16R MkII

Страница 1: ...User Guide www focusrite com v1 0...

Страница 2: ...locking 9 Pull Up and Pull Down Operation 9 Level Controls 9 Sample Rate Converters 9 OTHER REDNET SYSTEM COMPONENTS 10 REDNET CONTROL 2 10 Status Icons 11 ID Identification 11 Tools Menu 11 Signal Ro...

Страница 3: ...inate are registered trademarks of Audinate Pty Ltd Box Contents RedNet D16R MkII unit 2 x IEC AC mains cables Safety information cut sheet Focusrite Pro Important Information Guide which provides lin...

Страница 4: ...dent level trim on each input and output channel and a Sample Rate Converter SRC on each input pair allows instant operation with any AES3 source irrespective of the sample rate or clocking of the Dan...

Страница 5: ...k Master or there is a sync to an external clock 4 RedNet Sample Rate Indicators Five orange indicators 44 1 kHz 48 kHz x2 multiple of 44 1 or 48 x4 multiple of 44 1 or 48 and sample rate PULL UP DOWN...

Страница 6: ...Net D16R MkII to the Ethernet network switch Adjacent to each network socket are LEDs which illuminate to indicate a valid network connection plus network activity 4 Secondary Network Port Secondary D...

Страница 7: ...channels 1 2 Software switchable May also be used as a clock source when fed with either AES3 or DARS Digital Audio Reference Signal AES3 distributed clock as per AES11 Software selectable 10 AES3 1 8...

Страница 8: ...nsure that when mounted in a rack the vents are not obstructed Do not mount RedNet D16R MkII immediately above any other equipment which generates significant heat for example a power amplifier Power...

Страница 9: ...ital Clocking Each RedNet D16R MkII will automatically lock to a valid Network Master via its Dante connection Alternatively If a Network Master is not present then the unit can be chosen as the Netwo...

Страница 10: ...ng RedNet and Red range interfaces The system presents an image for each hardware unit showing its control levels and function settings signal meters as well as critical status indicators for power su...

Страница 11: ...lid connection is present Locked Unit is successfully locked to the network changes to the red cross if not locked External Clock Green unit is locked to the external source Yellow unit is locking Red...

Страница 12: ...can be selected at any time Internal RedNet is network master but running from internal clock External BNC Input Word Clock External XLR Input DARS or Audio External DB25 Input pair 1 External DB25 In...

Страница 13: ...ault state Enable Plug in Control and Status On Off toggle Automatic Cut Each channel pair an On Off toggle Can be switched separately or All 1 8 9 16 Channel pairs can be set to automatically cut the...

Страница 14: ...n Cat 5 6 Core 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown Pin Signal 1 Screen 2 Hot ve 3 Cold ve Pin Signal 1 Out channels 7 8 14 Out channels 7 8 2 Ground...

Страница 15: ...78 dB to 0 dB in 1 dB steps per channel Rear Panel Connectivity AES3 Channel Count 16 x 16 AES3 channels Input and Output 2 x DB25 connectors AES59 Combined I O Tascam Digital Alternate Input optional...

Страница 16: ...n unit is network slave shows valid network lock When network master shows unit is locked to indicated clock source Flashing indicates invalid external clock present and unit has reverted to internal...

Страница 17: ...dure for resolving the warranty issue In every case it will be necessary to provide a copy of the original invoice or store receipt to the distributor In the event that you are unable to provide proof...