background image

Focus Enhancements FireStore FS-3 
 
FIRMWARE RELEASE NOTES 
FIRMWARE VERSION 1.3.2 
  
Thank you for downloading the latest version of firmware for the 
FireStore FS-3 DTE  
disk recorder.  Focus Enhancements recommends that you update to this 
latest version of  
firmware if you are presently using a version older than what is noted 
above.  To display  
the current software version, turn on your FS-3 unit, select MENU and 
scroll down to OS  
VERSION NO.  Pressing SEL will display the current version. 
 
IN ORDER TO DOWNLOAD THIS FIRMWARE, YOU WILL REQUIRE THE  
FOLLOWING: 
 
1) Windows 98SE, ME, 2000, XP or Macintosh OS9.1 or later computer 
system with an  
active OHCI compliant FireWire (IEEE-1394) port. 
2) Focus Enhancements FireStore FS-3 DV Disk Recorder 
3) Focus Enhancements FSHDD-1 FireWire disk drive or other FAT32 
formatted  
FireWire disk drive. 
4) 6-pin to 6-pin FireWire (IEEE-1394) connector.   
5) Copy of Release Notes available. 
 
FIRMWARE INSTALLATION INSTRUCTIONS: 
To install new firmware to FS-3, do the following: 
 
1) Download software from the Focus Enhancements website  
(http://www.focusinfo.com/support/updates.htm) to your FireWire 
equipped computer  
system (see requirements above). 
2) Unzip file using WinZip (Windows) or Stuffit (Macintosh) on a 
computer system. 
3) Once downloaded and unzipped, rename the file called "XXXX.bin" to 
"fs3.bin"  
(please ensure that spelling, punctuation and case is the same as 
listed). 
4) Connect a FireWire disk drive that has been used with FS-3 (or other 
FAT32 formatted  
drive) to the computer and copy over the file "fs3.bin". 
5) Disconnect the FireWire drive from the computer (ensure to properly 
dismount the  
drive first), and connect to FS-3.  Power on FS-3 as per normal. 
6) Enter the FS-3 menu and select "SETUP".  From the SETUP menu, select 
"OS  
UPGRADE". 
7) When prompted, "DO YOU WANT TO UPGRADE SYSTEM SOFTWARE?",  
answer YES and YES again to the erase current OS warning messages.  
Upgrade will  
begin. 
8) After upgrade is complete, power cycle FS-3.  The new software 
should be loaded and  

Отзывы: