5.1 Firmware upgrade

Warning: Please disconnect any load when connecting to PC for software

upgrade!After opening the PC software to connect the device,After selecting the

correct latest device firmware file and data packet length ( Free Choice),Just

proceed with the firmware upgrade operation. Do not power off the device during

the upgrade process.It will cause the upgrade to fail and cause the device to

crash.

If the upgrade fails accidentally, please disconnect the power and press and hold

the ">" button to power on the device.

Try to re- enter the upgrade mode and turn on the upper computer again to

upgrade the firmware.After the firmware upgrade is successful, the device will

automatically run the latest firmware and the PC software will restart.

5.2 Control operation

First, you must open the correct serial port number before the connect device

button will take effect.When operating the host computer, all control input boxes

cannot be empty,And only numbers and decimal points can be entered ( the

decimal point can only be entered in a specific position to take effect,For example,

voltage 10 . 00 , current 3 . 000 , power 360 . 0 ),The setting will not take effect

until the cursor leaves the input box.

The waveform can be observed by the waveform status light,to determine

whether the waveform status is acquired in real time( Green represents acquiring

data waveform, red represents pause to acquire data waveform), The “ start/

pause” next to the waveform can control the waveform status light,The waveform

can also be zoomed in

by

selecting the designated area with the left mouse

Содержание DC6006L

Страница 1: ...DC6006L CNC DC adjustable power supply Product Manual July 25 2020 Shen Zhen FEI NI RUI SI TECHNOLOGYCO LTD...

Страница 2: ...ers 1 3 Features 2 3 1 Interface diagram 2 3 2 Parameter setting description 3 3 2 1 System settings 3 3 2 2 Software protection settings 3 3 3 Intelligent temperature control system 4 3 4 PD Interfac...

Страница 3: ...is simple and rich 2 Parameter Description 2 1 Basic Parameters 1 Input voltage Banana head 6 70V input DC 6 30V input PD 80W input 2 The Output voltage 0 60V note ensure that the input voltage is gre...

Страница 4: ...t default 61V 3 Output overcurrent protection OCP 0 6 1A custom adjustment default 6 1A 4 Output over power protection OPP 0 360W custom adjustment default 360W 5 Output over temperature protection OT...

Страница 5: ...at a specified time the maximum support 100h 4 D i s p l a y d i r e c t i o n se t th e d i r e c t i o n of 36 0 d e g r e e r o t a t i o n 5 Temperature unit Set the temperature unit or 3 2 2 Soft...

Страница 6: ...set time it will alarm OHP 3 3 Intelligent temperature control system When the product temperature is greater than 40 C or the output current is greater than 2A the fan automatically starts and the f...

Страница 7: ...setting parameters Support PD charger and DC DC power adapter for direct power supply It also supports a series of functions such as PC software upgrade and control 4 Key Description Knob operation i...

Страница 8: ...rresponding serial port number if the serial port number is not found please check whether the computer is installed with the CH340 driver and then open the serial port click to connect the device the...

Страница 9: ...e device will automatically run the latest firmware and the PC software will restart 5 2 Control operation First you must open the correct serial port number before the connect device button will take...

Страница 10: ...higher than 1 1 times the operating power of the load equipment 2 Before charging the lithium battery with constant current please check the battery parameters and after setting the voltage and curren...

Отзывы: