FMS EMGZ306A Скачать руководство пользователя страница 1

 

 

 
 
 
 
 
 
 

Operating Manual  

EMGZ306A/ EMGZ306A.10V 

Compact analogue Tension Measuring Amplifier 

 
 

Version 2.04  04/08  st 

 
 
 
 
 
 
 
 

This operation manual is also available in German, French and Italian. 

Please contact your local representative. 

 
 

Diese Bedienungsanleitung ist auch in Deutsch, Französisch und Italienisch erhältlich. 

Bitte kontaktieren Sie die Vertretung im zuständigen Land. 

 
 

Ce mode d'emploi est également disponible en Français, en Italien et en Allemand. 

Veuillez contacter la représentation locale. 

 
 

Queste manuale d’installazione è disponibile anche in lingua italiano, francese e tedesco. 

Vogliate cortesemente contattare la locale rappresentanza. 

 
 
 

© by FMS Force Measuring Systems AG, CH-8154 Oberglatt – All rights reserved. 

021-51085998

Содержание EMGZ306A

Страница 1: ...utsch Französisch und Italienisch erhältlich Bitte kontaktieren Sie die Vertretung im zuständigen Land Ce mode d emploi est également disponible en Français en Italien et en Allemand Veuillez contacter la représentation locale Queste manuale d installazione è disponibile anche in lingua italiano francese e tedesco Vogliate cortesemente contattare la locale rappresentanza by FMS Force Measuring Sys...

Страница 2: ...not followed malfunction can be the result 1 2 List of safety instructions Proper function of the Tension Measuring Amplifier is only guaranteed with the recommended application of the components In case of other arrangement heavy malfunction can be the result Therefore the installation instructions on the following pages must be followed strictly Local installation regulations are to preserve saf...

Страница 3: ... 2 Force sensors 5 4 3 Measuring amplifier EMGZ306A 5 4 4 Block diagram 6 5 Dimensions 6 6 Installation and wiring 7 6 1 Mounting and wiring of the electronic unit 7 6 2 Mounting the force sensors 7 6 3 Wiring 8 7 Setting into operation 9 7 1 View of the setting elements 9 7 2 Configuring the outputs 9 7 3 Configuring the lowpass filter 10 7 4 Calibrating the measuring amplifier 10 8 Trouble shoot...

Страница 4: ...of the feedback value 3 System components The EMGZ306A consists of the following components refer also to fig 1 Force sensors For mechanical electrical conversion of the tension force Force measuring bearing Force measuring roller Force measuring journal Force measuring bearing block Measuring amplifier EMGZ306A Design with compact plastic housing Housing fits directly to a DIN mounting rail Gain ...

Страница 5: ... strain gauges the measured value is according also to the power supply So the force sensors are supplied from the EMGZ306A by a very accurate power supply 4 3 Measuring amplifier EMGZ306A The EMGZ306A is a single channel analog Tension Measuring Amplifier It is delivered in a compact housing which may be snapped on a DIN mounting rail directly All connections are led to screw terminals There can ...

Страница 6: ...Operating manual EMGZ306A 6 4 4 Block diagram standard 5V option 10V fig 2 E306007e 5 Dimensions Power Gain Offset fig 3 E306008us ...

Страница 7: ...ic unit The plastic housing of the measuring amplifier can be mounted in a control cabinet It is snapped on a DIN mounting rail directly Wiring to the terminals is done according to wiring diagram fig 4 6 2 Mounting the force sensors Mounting of the force sensors is done referring to the FMS Installation manual which is delivered together with the force sensors Wiring to the terminals of the elect...

Страница 8: ... value of the 2 sensors The connection between force sensors and measuring amplifier has to be done using 2x2x0 75mm2 AWG 18 shielded twisted pair cable With cable length below 15m 2x2x0 25 mm2 AWG 23 is also suitable The cable must be installed separate from power lines Terminal 3 has to be connected to earth Caution Bad earth connection may cause electric shock to persons malfunction of the tota...

Страница 9: ...A or 4 20mA which are active simultaneously The signal of the current output is configured as follows Current output 4 20mA The jumpers have to be set to X1 X2 fig 6 This is the standard FMS factory setting Current output 0 20mA The jumpers have to be set to X3 X4 fig 7 Compound filled version EMGZ306A 581820 for rotating applications Solder bridges are used instead of the jumpers to ensure the vi...

Страница 10: ...capacitors because positive and negative signals are appearing They would damage the electrolytic capacitor 7 4 Calibrating the measuring amplifier Connect gauge to the tension resp current output Connect the first force sensor Check if a positive output signal is appearing when loading the sensor in measuring direction If not exchange the two signal wires of the referring force sensor in the term...

Страница 11: ...utput isn t 0V Connect Gnd terminal of the output terminal 5 with earth terminal 3 Output shows no reaction or LED don t light Fuse blown Replace fuse on power supply Power supply not correct Check correct power supply Measuring amplifier defect Contact FMS customer service 9 Technical Data Sensor excitation 5VDC max 30mA high precision option 10VDC Gain factor range 500 5000 Offset range 9mV Temp...

Страница 12: ...80 80 Fax 0041 44 850 60 06 info fms technology com www fms technology com FMS USA Inc 925 East Rand Road Suite 207 Arlington Heights IL 60004 USA Tel 847 392 7872 Fax 847 392 7873 fmsusa fms technology com FMS UK Highfield Atch Lench Road Church Lench Evesham WR11 4UG Great Britain Tel 021 51085998 Fax 01386 871021 ...

Отзывы: