Operating Manual BKS309.MS
14.08.2018
14
6.2
Relays Outputs
The BKS309 controller provides 2 programmable relay outputs. The outputs are
software controlled. Electrically they are potential-free. Each relay output can be
configured individually and can perform an assign special function. The outputs are
configured in the Parameter Setting Mode. Following functions can be assigned to
each output:
•
Indicate centre position of web edge
•
Indicated if web edge is detected
•
Indicate if web edge is detected and Automatic Mode on
•
Indicate if no web edge is detected and Automatic Mode on
•
Indicate if Automatic Mode was chosen
•
Indicate if steering frame or actuator is centred
For more details about the functions refer to chapter 7.4 “
Description Operation
Parameter
”.
Hardware access via screw terminals (see Fig. 3)
Signal Name
Terminal #
Relay 1/1
9
Relay 1/2
10
Relay 2/1
11
Relay 2/2
12
6.3
Digital Inputs
The BKS309 controller provides 4 digital inputs for special functions.
The digital inputs are edge or level triggered. An impulse of 100ms or longer
activates the event. Each digital input can be configured individually and can perform
an assign special function. The digital inputs are configured in the Parameter Setting
Mode. Following function can be assign to each digital input:
•
Toggle between Manual and Automatic mode (edge triggered)
•
Toggle between Manual and Automatic mode (level triggered)
•
Go to centre position
•
Decrease reference value in 0.1mm steps in (deactivated for BKS309.MS)
•
Move actuator in 0.1mm steps to the left
•
Increase reference value in 0.1mm steps (deactivated for BKS309.MS)
•
Move actuator in 0.1mm steps to the right
•
Lock steering device (steering frame or actuator)
•
Reset reference value (deactivated for BKS309.MS)
For more details about the functions refer to chapter 8.4 “
Description Operation
Parameter
”.
Содержание BKS309.MS
Страница 20: ...Operating Manual BKS309 MS 14 08 2018 20 Fig 13 State Diagram Operation Parameters 1 K309009e...
Страница 21: ...Operating Manual BKS309 MS 14 08 2018 21 Fig 14 State Diagram Operation Parameters 2 K309010e...
Страница 22: ...Operating Manual BKS309 MS 14 08 2018 22 Fig 15 State Diagram Operation Parameters 3 K309011e_MS...
Страница 23: ...Operating Manual BKS309 MS 14 08 2018 23 Fig 16 State Diagram Operation Parameters 4 K309014e_MS...
Страница 43: ...Operating Manual BKS309 MS 14 08 2018 43 Fig 22 Parameter setting and Remote Control Remote Control...
Страница 44: ...Operating Manual BKS309 MS 14 08 2018 44 Fig 23 Parameter list webMASTER Steering Frames wMASTER jpg...
Страница 45: ...Operating Manual BKS309 MS 14 08 2018 45 Fig 24 Parameter list winderGLIDE Actuators wGLIDE jpg...