FMI V300 Скачать руководство пользователя страница 1

IN-V300-08

1

V300 SET UP INSTRUCTIONS

 FOR ADDITIONAL REFERENCES SEE H431 AND Q431

Before using any Fluid Metering, Inc. product read the following safety instructions 

as well as specific product specifications and operating instructions.

Warning! 

Fire, electrical shock or explosion may occur if used near combustibles 

explosive atmosphere, corrosive air, wet environment or submerged in fluid.

!

Caution! Fire, electrical shock, injury and damage may 
occur if not used in accordance with Fluid Metering, Inc. 
specifications and operation instructions.  

Do not put wet fingers into power outlet of unit.
Do not operate with wet hands.
Do not operate drive assemblies that require a hard mount 

(to be bolted down) unless they are mounted per Fluid Metering. 
specifications, if not injury may occur and/or damage to unit.

Do not touch any rotating pump or motor components: injury 

may occur.

Do not run pump dry, unless designed for that service.

Running dry is harmful to the pump, and will cause excessive 
heating due to internal friction.

Check pump rotation and inlet/outlet pump port orientation 

before connecting power to pump.  If not injury may occur.

When pulling out cords from outlets do not pull cord, grasp 

plug to prevent plug damage or electrical shock.

Fluid Metering, Inc. Drive Motors become HOT and can 

cause a burn

DO NOT TOUCH!

Turn off the electrical power before checking pump for any problems.
Connect motor, speed controllers, or any other electrical devices 

based on Fluid Metering Inc. specifications.  Any unauthorized work            
performed on the product by the purchaser or by third parties can    
impair product functionality and thereby relieves Fluid Metering, Inc. 
of all warranty claims or liability for any misuse that will cause 
damage to product and/or injury to the individual. 

Power cables and leads should not be bent, pulled or inserted by    

excessive force. Otherwise there is a threat of electrical shock or fire.

Replace any inline fuses only with fuse rating as specified by 

Fluid Metering, Inc.

When pump/drive is under operation, never point discharge tubing 

into face or touch any rotating components of pump. In a power 

down  thermal overload cut-in condition, unplug or turn off power 
to pump. Always allow a cool down period before restarting: 
otherwise, injury or damage may occur.
For 30 seconds after power is removed from pump/drive: do not 

touch any output terminals. Electrical shock may occur because of  
residual voltage.

!

SAFETY INSTRUCTIONS

!

Figure 1

Figure 2

Содержание V300

Страница 1: ...ccur When pulling out cords from outlets do not pull cord grasp plug to prevent plug damage or electrical shock Fluid Metering Inc Drive Motors become HOT and can cause a burn DO NOT TOUCH Turn off the electrical power before checking pump for any problems Connect motor speed controllers or any other electrical devices based on Fluid Metering Inc specifications Any unauthorized work performed on t...

Страница 2: ... The system is configured for table top installation ini tially with rubber grommets slid into the mounting slots Before moving on to configuring the control module make sure that these rubber grommets are in place There are no further installation steps for table top use 3 1 2 Wall Mounting For wall mounting it is necessary to remove the four rubber grommets from the control module before attempt...

Страница 3: ...Mode Use this mode to remotely control the stroke rate with a voltage input source of 0 to 10 VDC This voltage level interface utilizes the ANALOG INPUT connector on the control module to connect to the user s voltage source Standard RG58 or other coaxial cable should be utilized for inducted noise immunity See Figure 2 for cable connections The 0 10 VDC interface requires approximately 1 mA of dr...

Страница 4: ...able to the AC power out let a Do not attempt to apply power to the control unit until all of the above installation and set up procedures have been completed b Double check reversing and mode switches prior to turning on the power switch c Since the pump drive module can be a substantial distance from the control unit it is imperative the operator visually verify that the pump drive module is rea...

Страница 5: ...uropean Communities The fuse holder will not open without removing the power cord Once the power cord is removed simply pry up the fuse cover at the indicated screwdriver slots swing open the cover hinged towards the power sock et Then remove the fuse holder block by pulling it straight out exposing the fuses Always replace both fuses with the same type and rating even if only one has blown The V3...

Страница 6: ......

Страница 7: ...5 75 146 1 4 0 101 6 V300 OUTLINE V300 MOUNTING TEMPLATE Figure 4 ...

Отзывы: