background image

www.fmiproducts.com

125636-01A

16

CLEANING AND MAINTENANCE

Continued

INSPECTING BURNERS

Continued

Figure 30 - Incorrect Burner Flame Pattern

Dark Orange 

Flames

CLEANING AND MAINTENANCE

 

WARNING: Turn off appliance and let cool 

before cleaning.

  CAUTION:  You  must  keep  control  areas, 

burners and circulating air passageways of ap

-

pliance clean. Inspect these areas of appliance 
before  each  use.  Have  appliance  inspected 
yearly by a qualified service person. 

 WARNING: Failure to keep the primary air 

opening(s) of the burner(s) clean may result 
in sooting and property damage.

BURNER INjECTOR HOLDER AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to 
mix with the gas. This provides a clean burning flame. Keep 
these holes clear of dust, dirt, lint and pet hair. Clean these air 
inlet holes prior to each heating season. Blocked air holes will 
create soot. We recommend that you clean the unit every three 
months during operation and have appliance inspected yearly 
by a qualified service person. 
We also recommend that you keep the burner tube clean and 
free of dust and dirt. To clean these parts we recommend using 
compressed air no greater than 30 PSI. Your local computer 
store, hardware store or home center may carry compressed 
air in a can. If using compressed air in a can, please follow 
the directions on the can. If you don’t follow directions on the 
can, you could damage the pilot assembly.
1.  Shut off unit. Allow unit to cool for at least thirty minutes.
2.  Inspect burner, and primary air inlet holes on injector holder 

for dust and dirt (see Figure 31).

3.  Blow air through the ports/slots and holes in the burner.
4.  Check injector holder located at end of burner tube again. 

Remove any large particles of dust, dirt, lint or pet hair with 
a soft cloth or vacuum cleaner nozzle.

5.  Blow air into the primary air holes on the injector holder.
6.  In case any large clumps of dust have now been pushed 

into the burner repeat steps 3 and 4. Additional cleaning 
may be needed for proper operation based on use/lack of 
use.

Figure 31 - Injector Holder On Outlet Burner Tube

Burner Tube

Injector 

Holder

Primary Air 

Inlet Holes

LOGS

•  If you remove logs for cleaning, refer to 

Installing Logs and 

Lava Rock

, page 10, to properly replace logs.

•  Replace log(s) if broken or chipped (dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with appliance running. 
All slotted burner flame holes should be open with flame present. 
All round burner flame holes should be open with a small blue 
flame present. Some burner flame holes may become blocked 
by debris or rust, with no flame present. If so, turn off appliance 
and let cool. Remove blockage, blocked burner flame holes will 
create soot.

 

WARNING: The injector holders (air shut

-

ters) are not adjustable. Do not move injector 
holders from their original positions.

SPECIFICATIONS

MF42ONE AND MF48ONE 

•  Rating (Variable): 29,000/40,000 Btu/Hr
•  Type Gas: Natural
•  Ignition: Electronic
•  Manifold Pressure: 3.4" W.C.
•  Inlet Gas Pressure (in. of water):
  Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment

MF42OPE AND MF48OPE

•  Rating (Variable): 29,000/40,000 Btu/Hr
•  Type Gas: Propane/LP
•  Ignition: Electronic
•  Manifold Pressure: 10.0" W.C.
•  Inlet Gas Pressure (in. of water):
  Max - 14" W.C., Min* - 11" W.C.
*For purpose of input adjustment

Содержание MF42ONE

Страница 1: ... the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instruc tions thoroug...

Страница 2: ...mote accessory keep selector switch in the OFF position to prevent children from turning on burners with remote WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operation al procedures For assistance or additional information consult a qualified installer ser vice agency or the gas supp...

Страница 3: ...Maintenance page 16 8 Before using furniture polish wax carpet cleaner or similar products turn appliance off If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls and furniture 9 Do not use this appliance as a wood burning appliance Use only the logs provided with the appliance Do not burn solid fuels in this appliance 10 Do not run appl...

Страница 4: ...rson must install appliance Follow all local codes NOTICE State or local codes may only allow operationofthisapplianceinaventedconfigu ration Check your state or local codes WARNING Makesuretheselectorswitchisin the OFF position before installing appliance WARNING Never install the appliance in a recreational vehicle wherecurtains furniture clothingorotherflam mable objects are less than 36 from f...

Страница 5: ...e hood accessory 24 and 30 Models Only See Figure 3 for minimum clearances If Using Mantel You must have noncombustible material s above the fireplace opening Noncombustible materials such as slate marble tile etc must be at least 1 2 thick With sheet metal you must have noncombustible material behind it Noncombus tible material must extend at least 8 up for all models If noncombustible material i...

Страница 6: ...Fireplace Clearances Above Combustible Flooring Installation Continued Determining Minimum Mantel Clearance When Using a Hood If minimum clearances in Figure 4 are not met you must have a hood When using a hood there are still certain minimum mantel clearances required Follow minimum clearances shown in Figure 5 when using hood INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note When used ...

Страница 7: ...n for clarity 2 1 8 NPT Plugged Tapping MAIN IN OUT PILOT ADJ PILOT Pilot Adjustment Inlet Pressure Tap Outlet Pressure Tap Gas Shutoff Valve Flexible Gas Line Do NOT Kink 1 2 NPT Incoming Gas Line Set Screw Installation Items Needed hardware package provided with appliance approved flexible gas hose and fittings provided if allowed by local codes sealant resistant to propane LP gas not provided e...

Страница 8: ...s This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged appliance valves WARNING Use pipe joint sealant that is resistant to liquid petroleum LP gas Figure 11 External Regulator With Vent Pointing Down Propane LP Supply Tank External Regulator with Vent Pointing Down Installation Continued Figure 10 Attaching Base to Fireplace Floor Model Shown May Va...

Страница 9: ...imum inlet pressure for purpose of input adjustment Figure 12 Gas Connection Pipe Cap Tee Nipple Joint Gas Control 3 Minimum Sediment Trap Equipment Shutoff Valve With 1 8 NPT Tap Approved Flexible Gas Hose if allowed by local codes Propane LP From External Regulator 11 W C to 14 W C Pressure Natural From Gas Meter 5 W C to 10 5 W C Pressure 2 Cap off open end of gas pipe where equipment shutoff v...

Страница 10: ...nce see To Turn Off Gas to Appliance page 14 Figure 16 MF Series Burner System Log Compatibility Chart INSTALLING LOGS and Lava Rock WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury CAUTION Afterinstallationandperiodically thereafter checktoensurethatnoflam...

Страница 11: ...urner Tube Square Grate Find the back left log LMF42 SC D 018 or LMF48 SC 2 D026 See Figures 18 18A and 18B Figure 18A shows how the log must fit against the end of the burner Figure 18B shows how the notch in log fits against the vertical portion of the burner tube Place this log on the base assembly by inserting it from the left side as shown in Figure 18 You will need to twist the log slightly ...

Страница 12: ...20 Place this log on the base as shown in fig ures Vertical Portion of Burner Tube Find the front left log LMF42 SC D017 or LMF48 SC 3 D025 See Figures 19 19A and 19B The log has a rect angular stand off on the bottom that fits against the lip on the black metal base as shown in figure 19A The bottom of this log has a slot that fits over the second bar on the grate as shown in Figure 19B Place the...

Страница 13: ... D 021 or D028 Square Peg Square Grate Log Notch Figure 23 Installing Front Top Log Front Top Log D 024 Rectangular Peg Right Split Crossover Log D 022 Middle Split Log Figure 21A Installing Middle Split Log Rear Top Side View Figure 22 Installing Right Split Crossover Log Log Notch Burner Tube Find the front top log D 024 See Figure 23 The left end 7 of this log has a square hole that fits over a...

Страница 14: ...ight any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions C Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has be...

Страница 15: ...he module s internal receiver accepts the transmitter code there will be a series of confirming beeps The remote system is ready for use Remote Off Switch ADJ S Pilot Connection I Pilot Connection AF 4000 MOD Module Rt Side Figure 26 Gas Module Right Side AF 4000 MOD Module Lt Side AUX Connection Learn Button Figure 27 Gas Module Left Side Inspecting Burners Check burner flame patterns often IGNIT...

Страница 16: ...holder for dust and dirt see Figure 31 3 Blow air through the ports slots and holes in the burner 4 Check injector holder located at end of burner tube again Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner repeat st...

Страница 17: ...m Orange Orange Orange Red Brown Black Solenoid White Brown Brown Green Ignitor Pilot I S AUX AF 5000MOD AF 4000 AF 4000B P Control Module Black Black Optional D Red SWI SWI GND Black Red HI LO Main Black These wires are not used on this application ...

Страница 18: ... s clogged 8 Wire disconnected from gas con trol REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor 4 Replace ignitor 5 Adjust ignitor wires as shown in Figure 28 on page 15 Replace ignitor assembly if repositioning does not correct the problem 6 Replace ignitor 7 Install new alkaline battery in remote control and batter...

Страница 19: ...l air is re moved from line Have gas line checked by local natural or pro pane LP gas company 2 Observe minimum installation clearances see pages 9 through 11 3 Clean burner see Cleaning and Maintenance page 16 or replace burner orifice s 1 Turn appliance off when using fur niture polish wax carpet cleaners or similar products 1 Replace batteries in battey pack and in hand held remote 1 This is no...

Страница 20: ...t hairspray glues cleaners chemicals new carpet etc See IMPORTANT statement above 2 Low fuel supply propane LP only 3 Gas leak See Warning state ment at top of page 1 Low line pressure 1 Gas leak See Warning state ment at top of page 2 Control valve or gas control de fective 1 Gas leak See Warning state ment at top of page REMEDY 1 Open window to ventilate room Stop using odor causing products whi...

Страница 21: ...ed on the back page of this manual FIREPLACE HOOD Black GA6050 Antique Brass GA6053 For all models Helps deflect heat away from mantel or wall above fireplace Fits openings 28 to 48 wide DAMPER CLAMP GA6080 For all models Permanently opens chimney flue damper for vented operation LAVA ROCK GA6060 For all models Order when additional rock is desired MAGNIFLAME ACCESORY LOG KIT LAMF MAGNIFLAME ember...

Страница 22: ...www fmiproducts com 125636 01A 22 Parts Remote Ready Control Models MF42oNe MF42oPe MF48oNe MF48oPe 1 2 4 5 6 7 8 9 10 11 12 13 15 16 18 19 20 21 23 24 25 26 22 17 14 8 3 ...

Страница 23: ...ytech 1 125647 02 Srew 00 Min Rate Skytech 1 15 125607 01 Cap 3 8 Compression 1 16 112823 01 T Fitting Brass 3 8 Tube x 3 8 NPT 1 17 125603 01 Grate MF42 Stainless Steel 1 125603 02 Grate MF48 Stainless Steel 1 18 111817 01 Flextube Dormont 3 8 X 15 1 19 111824 01 Brass Compression Cap Slv 3 8 1 20 124933 01 Orifice Holder 90 Degree Elbow 1 21 099056 49 Orifice 128 1 099056 31 Orifice 070 1 22 116...

Страница 24: ...te the set size KEY NO DESCRIPTION QTY Part Number Log ID Number Part Number Log ID Number 1 125573 01 D 019 125591 01 D 027 Log Front Right 1 2 125573 02 D 018 125591 02 D 026 Log Back Left 1 3 125573 03 D 017 125591 03 D 025 Log Front Left 1 4 125573 04 D 020 125573 04 D 020 Log Charred 1 5 125573 05 D 021 125591 04 D 028 Log Middle Split 1 6 125573 06 D 022 125573 06 D 022 Log Right Split Cross...

Страница 25: ...tioning purchase date Usually we will ask you to return the part to the factory Service Hints When Gas Pressure Is Too Low burners will have delayed ignition appliance will not produce specified output propane LP gas supply may be low You may feel your gas pressure is too low If so contact your local propane LP or natural gas supplier Technical Service You may have further questions about installa...

Страница 26: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Страница 27: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Страница 28: ...r FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material laborandincidentalcostsassociatedwithwarrantyrepairs unlessexpresslycovered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded from this warranty are pr...

Отзывы: