Pumps with the optional CAS equipment with a 12-lead auxiliary cable are mounted with the following
possible options:
• Leakage sensor in the oil housing (CLS)
• Analogue temperature sensor (Pt100) for support bearing temperature monitoring. (Requires separate
Pt100 relay.)
Pumps with the optional CAS equipment 24-lead auxiliary cable have the same options as for the 12-lead
cable, and two additional analogue temperature sensors (Pt100) for stator winding temperature in 3 phases.
(Requires addtional Pt100 relays.)
The CAS system has been replaced by the MAS system. CAS is no longer available as a spare part, but if
necessary CAS may be replaced by the MAS 711 together with the MRM-01 relay. For more information
see
CAS or MAS 711 + MRM-01 sensor connections
(page 55).
Sensors
6X5 drive units
6
4
7
8
2
1
3
5
WS000628A
1.
Vibration – VIS 10
2.
Leakage in the junction box – FLS, Float Switch Leakage Sensor
3.
Stator winding temperature
4.
Main bearing temperature – Pt100 analogue temperature sensor
5.
Leakage in the stator housing – FLS
6.
Water in oil
(not available in explosion-proof drive units)
– CLS, Capacitive Leakage Sensor
7.
Support bearing temperature – Pt100 analogue temperature sensor
8.
Pump memory
Product Description
C3300/6x5, C/R3231, C3240, C3306, C3312, C3351, C3356, C3400, C3501, C3531, C3602, C3800 Installation,
Operation and Maintenance Manual
27