background image

SHARK400

BSW

Please read these user manual carefully before use!

E

-

mail:

n

Address: No. 43, Yunfeng Road, Xiuquan Street, 
Huadu District, Guangzhou, China

Содержание Light Sky SHARK400BSW

Страница 1: ...SHARK400BSW Please read these user manual carefully before use E mail n Address No 43 Yunfeng Road Xiuquan Street Huadu District Guangzhou China...

Страница 2: ...viced correctly and safely My company disclaims all liability for damage to the fitting or to other property or persons deriving from installation use and maintenance that have not been carried out in...

Страница 3: ...on Keep all combustible materials at least 1 m away from the fixture Protection against electrical shock Connection must be made to a power supply system fitted with efficient earthing Class I applian...

Страница 4: ...ce The maximum temperature that can be reached on the external surface of the fitting in a thermally steady state is 100 Maintenance Before starting any maintenance work or cleaning the projector cut...

Страница 5: ...et The lamp needs electricity when setting the address code Software upgrade Insert USB upgrade software Display Menu The display panel adopts a 2 0 inch LCD12864 LCD screen which is used in both Chin...

Страница 6: ...tic gobo wheel C M Y CMY color mixing system 1 Dark red 2 Orange 3 Aquamarine 4 Dark green 5 green 6 Lavender 7 Pink 8 Yellow 9 Magenta 10 Cyan 11 CT02 12 Ct01 13 CTB 14 Dark blue 1 2 3 4 5 6 7 8 9 10...

Страница 7: ...9 7 40 3 7 4480 416 4 28 2 6 distance spot diameter and illumination diagram Beam model 3120 290 5 10 15 20 25 30 35 40 0 0 3 6 9 12 15 15 12 9 6 3 3 42 Distance m 3 Diameter m 42 Diameter m 0 46 7 52...

Страница 8: ...ATTACHMENT AND BODY SIZE 7 2 329 265 433 320 754 567 45 97 509 370 270 117...

Страница 9: ...must be securely fixed to the support structure of the projector and then connected to the base handle 8 Make sure all parts for fixing the projector are in a good state of repair Make sure the point...

Страница 10: ...ection to the eiectricty mains must be carried out by a qualified electrical installer The stage lighting power supply can not be more than 2pcs pre line power in power end out in The N terminal is co...

Страница 11: ...10 DMX output 1 Shield 2 Signal Signal Not connected Not connected 3 1 2 3 DMX input Shield Signal Signal Not connected Not connected 4 5 4 5 DMX512 in out in out in signal end...

Страница 12: ...11 6...

Страница 13: ...ter OK function Exit in the choice screen UP DOWN LEFT RIGHT ENTER Press the switch The projector starts resetting the effects At the same time the following information scrolls on the display please...

Страница 14: ...OutFan3 R 8 In Fan1 R 9 In Fan2 R DMX Live 1 Pan 2 Pan Fine 3 Tilt 4 Tilt Fine 5 Functions 6 Dimmer 7 Shutter 8 Cyan 9 Magenta 10 Yellow 11 Colour 12 StaticGobo 13 Rot Gobo 14 Gobo Rot 15 Prism 1 16 P...

Страница 15: ...hannel control 1 Pan 2 Pan Fine 3 Tilt 4 Tilt Fine 5 Functions 6 Dimmer 7 Shutter 8 Cyan 9 Magenta 10 Yellow 11 Colour 12 StaticGobo 13 Rot Gobo 14 Gobo Rot 15 Prism 1 16 Prism1 Rot 17 Prism 2 18 Pris...

Страница 16: ...00 255 NC NC 000 255 Focus 000 255 Zoom 000 255 Colour 000 255 Gobo 000 255 Prism 1 000 255 Prism 2 000 255 NC NC 000 255 Frost 000 255 Cyan 000 255 Magenta 000 255 Yellow 000 255 Rota Gobo 000 255 Re...

Страница 17: ...5 Reserved 106 107 Reserved 108 119 Reserved 120 124 Reserved 125 129 Reserved 130 139 Lamp On 140 149 Pan Tilt reset 150 159 Colour system reset 160 169 Gobo wheels reset 170 179 Dimmer Shutter reset...

Страница 18: ...arine 29 32 Aquamarine Green 33 36 Green 37 40 Green Light Green 41 44 Light Green 45 48 Light Green Lavender 49 52 Lavender 53 56 Lavender Pink 57 60 Pink 61 64 Pink Yellow 65 68 Yellow 69 72 Yellow...

Страница 19: ...w Fast Speed 178 190 Gobo11 Shake Slow Fast Speed 191 207 Effect Shake Slow Fast Speed 208 226 Forwards gobo wheel rotation from fast to slow 227 230 No rotation 231 249 Backwards gobo wheel rotation...

Страница 20: ...tion set position on channel 15 0 3 No rotation 4 34 35 65 66 96 97 127 128 188 Forwards prism rotation from fast to slow 189 194 No rotation 128 default 195 255 Backwards prism rotation from slow to...

Страница 21: ...8 Prism macro rotation 8 169 179 Prism macro rotation 9 180 190 Prism macro rotation 10 191 255 Raw DMX 20 Pattern rotation and indexing The channels are blocked Prism Wheel 1 2 Prism Wheel 1 2 rot Pa...

Страница 22: ...es 176 215 40 metres 216 255 50 metres 28 Effect Macro 0 15 Reserved 16 25 Effect 1 26 35 Effect 2 36 45 Reserved 46 55 Reserved 56 65 Reserved 66 75 Reserved 76 85 Reserved 86 95 Reserved 96 105 Rese...

Страница 23: ...22 CIRCUIT CONNECTING DIAGRAM...

Страница 24: ...an it up or the windmill will break down and causing fire CLEANING AND MAINTENANCES It is recommended some solution for some normal trouble shooting Any unsolutioned problems should always be handle b...

Страница 25: ...xcellent screening doublet Resistance 75 The end of the light end and the end resistance When the lamp don t cool down enough but do the incorrect operation will let the trigger up to super high volta...

Страница 26: ...ir Any products broken that didn t according to the instruction is not guarantee to keep it in good repair The commentary for all the instruction belongs to the supplier in final No authorize can t co...

Отзывы: