- 3 - 

Appropriate use 

The device may only be used if it is in perfect condition, and then only for its intended purpose, in compliance 
with  all  safety  regulations,  with  an  awareness  of  the  potential  risks,  and  according  to  the  operating 
instructions. Any faults that may impair the safety must be rectified immediately. 

The  system  and  its  components  are  only  to  be  used  for  handling  the  liquids  listed  and  the  purpose  described. 
Using the machine for any other purpose would constitute inappropriate use. The manufacturer is not responsible 
for any damages arising as a result of this, the risk for this is borne only by the operator. 

In the event of the measuring medium being contaminated by particles >150 µ, it is vital that suitable filters are 
used. If not the flow meter could become clogged and impaired in its operability. 
When used in the urea range (AUS32), the urea solution must be in accordance with DIN 70070.   

 

Organisational measures 

These  operating  instructions  should  always  be  kept  readily  available  at  the  site  of  operation!  Each  person 
concerned with the assembly, commissioning, maintenance and operation of the equipment must have read 
and understood the entire manual. It is essential that the type plate and the warnings attached to the device 
are observed, and are maintained in a fully readable condition. 

Qualified Personnel 

The operating, servicing and assembly personnel must be appropriately qualified for their work. The areas of 
responsibility,  the  accountability  and  the  supervision  of  the  personnel  must  be  precisely  determined  by  the 
operator.  If  the  personnel  do  not  have  the  required  knowledge,  they  must  be  trained  and  instructed.  The 
operator  must  also  ensure  that  the  contents  of  the  operating  instructions  are  properly  understood  by  the 
personnel. 

Water Protection 

The  device  has  been  designed  to  handle  materials  that  are  hazardous  to  water.  The  regulations  (e.g.  WHG, 
VawS) applying to the site of operation are to be observed. 

Servicing and Maintenance 

According  to  the  statutory  regulations  only  specialist  contractors  are  to  be  entrusted  with  work  on  systems  for 
liquids  that  are  harmful  to  water.  No  alterations,  extensions,  or  conversions  of  the  device  with  potential  impact 
upon safety are permitted without prior consent of the manufacturer. Spare parts must comply with the technical   

 requirements specified by the manufacturer. This is always assured if original spare parts are used. 

 

Except for battery changing, only the manufacturer is to undertake manipulations of whatever kind on the flow 
meter. 

Electric power 

Work  on  the  electrical  equipment  of  the  device  may  only  be  carried  out  by  a  qualified  electrician  or  by  trained 
persons  under  the  guidance  and  supervision  of  a  qualified  electrician  according  to  electro  technical  guidelines. 
Machine or system parts, on which inspection, maintenance or repair work is to be carried out, must be  

 

 de-energised.  

Hydraulics 

Only  persons  with  special  knowledge  and  experience  with  hydraulic  systems  may  carry  out  work  on  hydraulic 
parts and equipment. All lines, hoses and screw joints should regularly be checked for leaks and external  

 damage. Any damage must be rectified immediately. Any oil spurting out can cause injuries and fire. The relevant   
 safety regulations must be followed when handling oils, greases or other chemical substances! 

 

 

 

 

 

 

Содержание FMT 50 PP

Страница 1: ...roduct description 2 2 Safety instructions 2 3 Technical Description 4 4 Operation 4 5 Fault monitoring 5 6 Meter programming 5 7 Spare parts construction and spare parts list 6 8 Dimensional Drawing...

Страница 2: ...ir which in the case of volume flow transfers the meter pulses to a reed switch on the evaluation electronic system 2 Safety instructions The device is a state of the art piece of equipment and has be...

Страница 3: ...erator If the personnel do not have the required knowledge they must be trained and instructed The operator must also ensure that the contents of the operating instructions are properly understood by...

Страница 4: ...e LC display indicates the metered volume since the last reset The display has three digits before the decimal point and two after 0 01 litres is the minimum digital step The litre measurement unit op...

Страница 5: ...ctor can be established a delivery must be made into a satisfactorily accurate vessel or undertaken by means of a reference meter The new calibrating factor is calculated as follows shown delivered ex...

Страница 6: ...olding the Total and Reset keys at the same time when setting the measurement unit or calibrating factor is to delete all the meter values and carry out an initialisation Following values are initiali...

Страница 7: ...uction and spare parts list Spare parts list Pos Description PP 10 Cover complete Battery A05 00 001 20 Measuring chamber typeplate A05 00 002 30 Battery 940 04 033 40 Four cylinder head screws DIN 91...

Страница 8: ...range 0 8 40 mPa s Operating pressure 4 bar Burst pressure 9 bar Accuracy uncalibrated 2 Accuracy calibrated 1 Repeat accuracy 0 5 Nominal width 1 External thread Protection category IP 65 Battery Li...

Страница 9: ...a construction du Compteur de D bit FLUX FMT 50 de mat riaux et versions diff rents est conforme aux dispositions r glementaires suivantes 1 EG Richtlinie Maschinen EC Machinery Directive Directive CE...

Страница 10: ...10 Talweg 12 75433 Maulbronn Telefon 07043 101 0 Telefax 07043 101 444 Fax International 49 7043 101 555 info flux pumpen de www flux pumpen de...

Отзывы: