Fluke TS52PRO Скачать руководство пользователя страница 21

17

Maintenance

After you dial the ANAC number and get a response, 
the phone number of the line pair that the test set is 
connected to is shown on the display. If the ANAC 
response is greater than 10 digits, the last 10 will be 
displayed. The test set is automatically muted in visual 
ANAC mode. If a visual response is not available, an 
audible response is given. 

You can also enter the ANAC number in speed dial 
location 9 and the test set automatically enters Visual 
ANAC mode when the speed dial is used. If a visual 
response is not available, an audible response is given. 
Use one of the other speed dial locations (0-8) if you 
always want an audible response.

ANAC mode is turned off when you switch to Monitor 
mode. If ANAC mode is off, the ANAC voice response is 
audible on the handset or speaker.

Factory Defaults

The Restore Defaults function lets you restore all 
programmable features to their original factory 
settings. This function does not clear stored telephone 
numbers. The defaults are:

Hook Flash: 600 ms

Speaker timeout: 2 minutes

Speakerphone: enabled

Receive-Only Loud Speaker: disabled

Backlight: off

DTMF Digit Grabbing: off

Monitor Mode timeout: 2 minutes

To restore the factory default values:

1

Set the Talk/Monitor switch to 

M

.

2

Press the 

STORE/PROG

 key.

3

Press the pound (#) key. The test set gives a 
confirmation tone when the entry is accepted.

Maintenance

W

Warning

X

Disconnect the test set’s alligator clips from 
any metallic connections before performing 
any maintenance. Read all instructions 
completely and understand possible hazards 
to end user if repairs are not performed 
properly.

Batteries are hazardous to handle. Do not 
allow the terminals to be shorted together. 
Severe burns or explosion can result if not 
handled properly. Dispose of the battery 
properly to ensure contacts cannot short. 
Disposal may be restricted by local laws.

Cleaning

For general cleaning, wipe the case, front panel keys, 
and lens using a soft cloth slightly dampened with 
water or a non-abrasive mild cleaning solution that 
does not harm plastics.

W

Caution

Do not use CRC Cable Clean

®

 or any 

chlorinated solvent or aromatic 
hydrocarbons on the test set. Doing so will 
damage the test set.

Replacing the Battery

See Figure 4.

To replace the 9 V battery:

W

Warning

X

Be sure to account for all hardware 
removed. Loose or missing hardware could 
create a hazard for the end user. Be sure to 
replace the battery with a good 9 V alkaline 
battery or the test set will not operate 
properly.

1

Disconnect the test set from the line and place on 
a flat work surface with the battery cover up.

Содержание TS52PRO

Страница 1: ...TS 52PRO Test Set PN 3394309 January 2009 Rev 5 5 2018 2009 2018 Fluke Corporation All product names are trademarks of their respective companies Users Guide...

Страница 2: ...ion to refund of the purchase price free of charge repair or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain war...

Страница 3: ...peaker and Speakerphone Microphone 4 Audio Controls 4 Display and Keypad 6 Operation 10 Talk Monitor Switch 10 Operating the Test Set in Monitor Mode 10 Caller ID 11 Operating the Test Set in Talk Mod...

Страница 4: ...ng a Stored Number 15 Hook Flash Duration 15 Make Receive Only Loud Speaker the Default 15 Speaker LCD Test Set Timeout 16 LCD Backlight 16 DTMF Digit Grabbing 16 Visual ANAC Mode 16 Factory Defaults...

Страница 5: ...uitry that prevents disruption of digital data services if the test set is unintentionally connected to a data line Registration Registering your product with Fluke Networks gives you access to valuab...

Страница 6: ...Safe in Monitor mode Data detection and lockout in Talk mode Data lockout override DTMF digit grabbing High impedance in Monitor mode High voltage protection Last number redial up to 23 digits Visual...

Страница 7: ...ded locking clip that assures a secure connection to belt loops and D rings Both forward folding and backwards folding versions of the belt clip may be installed The test set can be hung by the belt c...

Страница 8: ...the display shows no bars the battery should be replaced immediately The test set s battery compartment makes battery replacement easy See Replacing the Battery on page 17 for instructions on changin...

Страница 9: ...Speakerphone mode pressing the MUTE key will shut off the speakerphone s microphone and will temporarily put the test set into a Receive Only Loud Speaker mode This is a better mode for troubleshootin...

Страница 10: ...the section Speaker LCD Test Set Timeout on page 16 for information on setting the timeout SPKR Speaker The SPKR key turns the test set s speaker on and off It functions in both Talk and Monitor mode...

Страница 11: ...The factory default flash duration is 600ms however the duration of the flash signal can be varied by the user For configuring the test set to generate a flash duration other than 600ms see Hook Flas...

Страница 12: ...ou are working on has normal CO battery voltage or normal loop current If the voltage is below 2 5 V dc there is not enough voltage for the test set to go off hook If the voltage is above 140 V dc thi...

Страница 13: ...ne VOL Toggle volume Toggle volume SPKR Toggle speaker Toggle speaker RCL Initiate speed dial storage Initiate speed dial functions OVERRIDE N A Override data lockout LNR N A Dial last number STORE PR...

Страница 14: ...udio signals without disrupting conversations or data signaling that may be present Either the handset receiver or the speaker can be used to monitor a line Note Monitor Mode Only You can monitor a li...

Страница 15: ...pair Originating a Call 1 Set the Talk Monitor switch to M 2 Clip the test set to Tip and Ring of a subscriber loop 3 Monitor listen to the line to verify that it is idle 4 If not idle disconnect the...

Страница 16: ...Practices Always monitor the line for an audible signal before attempting to go off hook to draw dial tone The data detect circuitry on the test set is designed to detect data signals above the human...

Страница 17: ...e is present the test set goes off hook To go back on hook unclip the test set s test leads from the line or put the test set into Monitor mode High Voltage Lockout Operation WWarningX If the voltage...

Страница 18: ...is automatically muted If a visual response is not available an audible response is given Use one of the other speed dial locations 0 8 if you always want an audible response Putting a Pause in a Sto...

Страница 19: ...ly receive audio signals it cannot transmit any audio signals Receive only is preferred when your main concern is to listen to the line and you do not want ambient noise such as caused by a passing ca...

Страница 20: ...tion The test set gives a confirmation tone when the entry is accepted LCD Backlight You can conserve the test set battery life by keeping the display backlight off when it is not needed The default s...

Страница 21: ...ory default values 1 Set the Talk Monitor switch to M 2 Press the STORE PROG key 3 Press the pound key The test set gives a confirmation tone when the entry is accepted Maintenance WWarningX Disconnec...

Страница 22: ...eps Figure 4 Battery Replacement Replacing or Relocating the Belt Clip See Figure 5 The belt clip assembly is field replaceable in the event of damage or prolonged wear It also can be relocated to on...

Страница 23: ...all hardware removed Loose or missing hardware could create a hazard for the end user Note Battery cover screws are retained in the cover and will not come all the way out of the battery cover Be car...

Страница 24: ...nd washer Figure 8 3 Fasten the black wire lug to the PC board Tip with screw and washer Figure 8 4 Insert the plastic clip over the line cord strain relief at the base of the test set housing Figure...

Страница 25: ...ne Cord with Piercing Pin Clips P4480001 Central Office Line Cord with 346A Plug P4480004 Angled Bed of Nails Cord ABN and Piercing Pin Clips P4480009 Angled Bed of Nails Cord ABN with Piercing Pin Cl...

Страница 26: ...er programmable default of 600 ms Automatic Speaker Shut Off Duration User programmable default of 2 minutes Battery 9 V alkaline battery Physical Measurement 10 in x 3 75 in x 4 25 in 254 mm x 96 mm...