Fluke TS52PRO Скачать руководство пользователя страница 17

13

Operation

It is best to put the test set in Monitor mode when 
troubleshooting a line, searching for capacitance kicks, 
RF signals, craft provided tones, etc.

Data Lockout Override Operation

Normally, when the test set detects data, it means the 
operator has accidentally connected to a high-speed 
data line and should immediately disconnect from the 
line to avoid disrupting the data service. But in some 
cases the operator must go off-hook on a specific line 
even though the test set indicates that the line is a data 
line.

The following are scenarios where the operator may 
wish to override a data lockout:

When there is false data detection due to RF 
pickup on a line that is near an AM radio 
broadcast antenna. The RF induced in the line may 
appear to be data.

When performing a ground start, the test set may 
lock out when the Talk/Monitor switch is in the 

position. This is because ground start lines are 
unbalanced before startup and thus are prone to 
picking up a lot of noise which may appear to be 
data to the test set. If this occurs, use the override 
function to go off-hook on a ground start line.

Telephone lines near AM radio broadcast facilities pick 
up the RF signals from the broadcast antennas. 
Normally this is not a problem for the test set. If the line 
is well balanced, the test set will not see the RF signal 
because it is a common mode (longitudinal) signal. But 
if the line is unbalanced, part of the RF signal will be 
converted to a differential (metallic) signal. If the signal 
amplitude is high enough, it may be detected as high-
speed data by the test set. If you know for sure you are 
on such a line, use the override function to go off-
hook.

The data lockout override can be activated only when 
the Talk/Monitor switch is in the 

T

 position. To activate 

the override, press the 

OVERRIDE

 key. If dc voltage is 

present, the test set goes off-hook. To go back on-
hook, unclip the test set’s test leads from the line or put 
the test set into Monitor mode.

High Voltage Lockout Operation

W

Warning

X

If the voltage on the line is above 140 V dc, 
this is potentially dangerous to you and the 
test set. If you encounter this, carefully 
remove the test set’s clip leads from the line. 
Be sure to hold the clip leads by their 
insulated boots and avoid touching the clip 
lead’s metal parts with your hands. Do not 
short the test leads to each other while it is 
connected to a line carrying high voltage.

The TS52PRO is designed for use by Outside Plant and 
Central Office technicians in environments where 
analog voice lines co-exist with lines that carry high dc 
voltage.

Accidentally going off-hook on a line carrying a high dc 
voltage can damage the power supply feeding the line. 
To prevent this, the TS52PRO provides an automatic 
high-voltage lockout function. When a TS52PRO is 
connected to a Tip and Ring pair with its Talk/Monitor 
switch in the 

T

 position, it measures the voltage on the 

line before going off-hook. If the measured voltage 
exceeds 140 V dc, the test set locks out, preventing 
itself from going off-hook. The display shows 

LOCKOUT HI VDC

.

In the event of a high voltage lockout, the Talk/
Monitor switch should be set back to the 

M

 position, 

and the test set leads should be carefully removed from 
the line.

Configuring Your Test Set

When you are programming speed dial numbers or 
setting operating parameters, the test set expects you 
to press keys in a specific sequence. If, during a 
programming procedure, you accidentally press a key 
that’s out of sequence, the test set will abort the 
programming procedure and all you have to do is start 
the programming procedure over again. When you 
complete a programming procedure correctly, the test 
set will give you a confirmation tone. If you do not get 
a confirmation tone when you expect one, assume you 
made a programming error and just start the 
programming procedure over again.

Содержание TS52PRO

Страница 1: ...TS 52PRO Test Set PN 3394309 January 2009 Rev 5 5 2018 2009 2018 Fluke Corporation All product names are trademarks of their respective companies Users Guide...

Страница 2: ...ion to refund of the purchase price free of charge repair or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain war...

Страница 3: ...peaker and Speakerphone Microphone 4 Audio Controls 4 Display and Keypad 6 Operation 10 Talk Monitor Switch 10 Operating the Test Set in Monitor Mode 10 Caller ID 11 Operating the Test Set in Talk Mod...

Страница 4: ...ng a Stored Number 15 Hook Flash Duration 15 Make Receive Only Loud Speaker the Default 15 Speaker LCD Test Set Timeout 16 LCD Backlight 16 DTMF Digit Grabbing 16 Visual ANAC Mode 16 Factory Defaults...

Страница 5: ...uitry that prevents disruption of digital data services if the test set is unintentionally connected to a data line Registration Registering your product with Fluke Networks gives you access to valuab...

Страница 6: ...Safe in Monitor mode Data detection and lockout in Talk mode Data lockout override DTMF digit grabbing High impedance in Monitor mode High voltage protection Last number redial up to 23 digits Visual...

Страница 7: ...ded locking clip that assures a secure connection to belt loops and D rings Both forward folding and backwards folding versions of the belt clip may be installed The test set can be hung by the belt c...

Страница 8: ...the display shows no bars the battery should be replaced immediately The test set s battery compartment makes battery replacement easy See Replacing the Battery on page 17 for instructions on changin...

Страница 9: ...Speakerphone mode pressing the MUTE key will shut off the speakerphone s microphone and will temporarily put the test set into a Receive Only Loud Speaker mode This is a better mode for troubleshootin...

Страница 10: ...the section Speaker LCD Test Set Timeout on page 16 for information on setting the timeout SPKR Speaker The SPKR key turns the test set s speaker on and off It functions in both Talk and Monitor mode...

Страница 11: ...The factory default flash duration is 600ms however the duration of the flash signal can be varied by the user For configuring the test set to generate a flash duration other than 600ms see Hook Flas...

Страница 12: ...ou are working on has normal CO battery voltage or normal loop current If the voltage is below 2 5 V dc there is not enough voltage for the test set to go off hook If the voltage is above 140 V dc thi...

Страница 13: ...ne VOL Toggle volume Toggle volume SPKR Toggle speaker Toggle speaker RCL Initiate speed dial storage Initiate speed dial functions OVERRIDE N A Override data lockout LNR N A Dial last number STORE PR...

Страница 14: ...udio signals without disrupting conversations or data signaling that may be present Either the handset receiver or the speaker can be used to monitor a line Note Monitor Mode Only You can monitor a li...

Страница 15: ...pair Originating a Call 1 Set the Talk Monitor switch to M 2 Clip the test set to Tip and Ring of a subscriber loop 3 Monitor listen to the line to verify that it is idle 4 If not idle disconnect the...

Страница 16: ...Practices Always monitor the line for an audible signal before attempting to go off hook to draw dial tone The data detect circuitry on the test set is designed to detect data signals above the human...

Страница 17: ...e is present the test set goes off hook To go back on hook unclip the test set s test leads from the line or put the test set into Monitor mode High Voltage Lockout Operation WWarningX If the voltage...

Страница 18: ...is automatically muted If a visual response is not available an audible response is given Use one of the other speed dial locations 0 8 if you always want an audible response Putting a Pause in a Sto...

Страница 19: ...ly receive audio signals it cannot transmit any audio signals Receive only is preferred when your main concern is to listen to the line and you do not want ambient noise such as caused by a passing ca...

Страница 20: ...tion The test set gives a confirmation tone when the entry is accepted LCD Backlight You can conserve the test set battery life by keeping the display backlight off when it is not needed The default s...

Страница 21: ...ory default values 1 Set the Talk Monitor switch to M 2 Press the STORE PROG key 3 Press the pound key The test set gives a confirmation tone when the entry is accepted Maintenance WWarningX Disconnec...

Страница 22: ...eps Figure 4 Battery Replacement Replacing or Relocating the Belt Clip See Figure 5 The belt clip assembly is field replaceable in the event of damage or prolonged wear It also can be relocated to on...

Страница 23: ...all hardware removed Loose or missing hardware could create a hazard for the end user Note Battery cover screws are retained in the cover and will not come all the way out of the battery cover Be car...

Страница 24: ...nd washer Figure 8 3 Fasten the black wire lug to the PC board Tip with screw and washer Figure 8 4 Insert the plastic clip over the line cord strain relief at the base of the test set housing Figure...

Страница 25: ...ne Cord with Piercing Pin Clips P4480001 Central Office Line Cord with 346A Plug P4480004 Angled Bed of Nails Cord ABN and Piercing Pin Clips P4480009 Angled Bed of Nails Cord ABN with Piercing Pin Cl...

Страница 26: ...er programmable default of 600 ms Automatic Speaker Shut Off Duration User programmable default of 2 minutes Battery 9 V alkaline battery Physical Measurement 10 in x 3 75 in x 4 25 in 254 mm x 96 mm...

Отзывы: