background image

 

September 2014, Rev.1, 9/16 

© 2014, 2016 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. 
All product names are trademarks of their respective companies. 

TiX620, TiX640, TiX660, 

TiX1000 

Thermal Imager 

 

Shop for Fluke products online at:

1.888.610.7664

www.

MyFlukeStore

.com

Содержание tix1000

Страница 1: ...ion All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies TiX620 TiX640 TiX660 TiX1000 Thermal Imager Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 2: ...chnical Description 1 7 Functional Principle 1 7 Description of the Functional Units 1 7 Lens 1 7 Detector 1 10 Detector Electronics 1 10 Image Processing Electronics 1 10 Optomechanics 1 11 Controls 1 11 Power Supply 1 11 Interfaces 1 12 Technical Data 1 12 Unpacking and Control 1 15 Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 3: ...a Transmission to the Computer 1 26 Start Up 1 26 Hand Strap 1 26 Tripod 1 26 Power Supply 1 26 Memory Card 1 26 Lens Replacement 1 27 Operation using the Gigabit Ethernet GigE Interface 1 27 Ethernet Cable and AC Adapter 1 28 AC Adapter Connection 1 28 Operation with Breakout Box 1 28 2 Elements of the User Interface 2 1 Introduction 2 1 Button Functions 2 3 Image Elements 2 5 Setting the Tempera...

Страница 4: ... 3 5 Zoom Submenu 3 8 Palette Submenu 3 9 Elements Submenu 3 12 Isotherms Submenu 3 13 Filter Mode Submenu 3 15 Format Subwindowing Submenu 3 15 File Menu 3 16 Directory Structure 3 16 Load Submenu 3 16 Save Submenu 3 19 IR Photonotes Submenu 3 22 Format SD Submenu 3 23 Saving Format Submenu 3 23 Measure Menu 3 25 Spot Temperature Submenu 3 25 Measurement Definitions Submenu 3 26 Correction Submen...

Страница 5: ...menu 3 40 Digital Alarm Output Submenu 3 43 Configuration Submenu 3 44 System Menu 3 46 Display Submenu 3 47 Regional Submenu 3 48 Date and Time Submenu 3 48 Menu Layout Submenu 3 49 Menu Control Submenu 3 50 Info Submenu 3 51 4 Maintenance 4 1 Introduction 4 1 How to Clean 4 1 Calibration 4 2 Environmental 4 2 Service 4 2 Battery 4 3 Shop for Fluke products online at 1 888 610 7664 www MyFlukeSto...

Страница 6: ... with extraordinary image quality as well as the universal interface concept for digital real time thermography data collection using GigE Vision allow for using the thermal imager in a wide variety of applications The thermal imager is equipped with a digital color video camera in order to document the measuring situation on photos Infrared IR and visual light images as well as image sequences ca...

Страница 7: ...e thermographic inspection of electrical and mechanical systems optimization of components and assemblies material inspections control of process temperatures quality assurance building inspection and diagnostics research and development Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 8: ...l site Do not locate the laser beam so that it is at eye level when you install the thermography system The Product is equipped with an LED light to illuminate the image Avoid any direct eye contact and do not point the LED light at people animals or reflective surfaces Additional laser warning information is on the case of the Product see Figure 1 1 hvh300 eps Figure 1 1 Lens Cover Laser Warning ...

Страница 9: ...ries when the low battery indicator shows to prevent incorrect measurements Remove the batteries if the Product is not used for an extended period of time or if stored in temperatures above 50 C If the batteries are not removed battery leakage can damage the Product Batteries contain hazardous chemicals that can cause burns or explode If exposure to chemicals occurs clean with water and get medica...

Страница 10: ...y packs near heat or fire Do not put in sunlight Warning For safe operation and maintenance of the Product Repair the Product before use if the battery leaks Be sure that the battery polarity is correct to prevent battery leakage Use only Fluke approved power adapters to charge the battery Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 11: ...on Consult user documentation This Product contains a lithium ion battery Do not mix with the solid waste stream Spent batteries should be disposed of by a qualified recycler or hazardous materials handler per local regulations Contact your authorized Fluke Service Center for recycling information This product complies with the WEEE Directive marking requirements The affixed label indicates that y...

Страница 12: ...ns required for camera operation such as actuation of the microbolometer array A D conversion offset and gain correction pixel correction as well as actuation of the different interfaces Operation is optionally performed directly using the integrated keyboard joystick focus rocker switch function buttons or using optional interfaces RS232 Ethernet GigE Vision or USB2 0 are available as interfaces ...

Страница 13: ... 62 3 x 46 4 FLK Xlens Stan Standard lens 30 0 72 0 6 32 4 x 24 7 0 8 30 9 x 23 1 FLK Xlens Tele Telephoto lens 60 1 99 0 3 16 4 x 12 4 0 4 14 9 x 11 3 FLK Xlen SupTele Super telephoto lens 120 6 58 0 1 8 1 x 6 2 0 2 7 5 x 5 7 Model Lens Focal distance mm Focus mm IFOV mrad Resolution μm IFOV mrad Resolution μm FLK Xlens Macro1 Close up 0 2x for 30 137 4 85 5 x 63 2 81 78 1 x 57 9 119 FLK Xlens Ma...

Страница 14: ...le 1 3 Thermography System Lenses TiX620 640 x 480 Model Lens Minimum Focal distance mm Focus mm IFOV mrad FOV IR 1 10 Wide angle 250 1 0 10 1 70 57 1 44 4 IR 1 20 LW Standard 500 1 0 20 0 85 32 7 24 0 IR 1 40 LW Telephoto lens 1300 1 0 40 0 43 15 5 11 6 Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 15: ...ut circuit Use of an uncooled detector ensures the quick availability of the camera function at start up starting time 30 seconds and a long mean time to failure MTTF in continuous operation Detector Electronics Detector electronics supply the BIAS voltages and further actuation signals required for detector operation to ensure that the analog output signal of the detector is preprocessed and digi...

Страница 16: ...a joystick with center function Enter and the button Cancel can be found The controls of the thermal imager are arranged for single hand operation with the right hand Another multi function button can be found at the top of the handle When carrying the camera on its handle it can be operated using the thumb of your right hand Specific modes of camera operation and presettings can be configured usi...

Страница 17: ...L NTSC is available as FBAS signal composite on the 14 pin LEMO socket The HDMI socket can be used to connect screens processing a resolution of 1280 x 768 or 1280 x 800 in accordance with the VESA standard In connection with the provided software the GigE Vision interface allows for remotely controlling the thermography system as well as for transmitting digital image information to a PC in real ...

Страница 18: ...age temperature 40 C to 70 C 40 F to 158 F Operating altitude 2000 m Humidity relative humidity 10 to 95 non condensing Shock Operational 25G IEC 68 2 29 Vibration Operational 25G IEC 68 2 6 Protection class IP54 Safety meets IEC 60825 1 class 2 Electromagnetic Compatibility EMC International IEC 61326 1 Portable Korea Class A Equipment Industrial Broadcasting Communication Equipment Class A Equip...

Страница 19: ...rd Interfaces Supported in camera data ports image transfer SD card USB 2 0 video output DVI D HDMI GigE vision RS232 available in 2015 Supported in SmartView software SD card USB 2 0 GigE Vision RS232 available in 2015 Features Fluke Connect compatible AutoBlend mode LaserSharp Auto Focus TiX660 TiX1000 only Auto Focus Manual Focus EverSharp multifocal recording SuperResolution Dynamic SuperResol...

Страница 20: ...ermal Imager Components THERM AL IMAGER TiX640 2 3 4 5 6 1 7 8 9 hvh013 eps Item Description Item Description Multifunction button Connection for power supply trigger FBAS Handle SD card slot Color TFT viewfinder TiX660 Tix1000 only USB port Lithium ion battery DVI port Connection for GigE Vision RS232 Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 21: ...Front View of Thermal Imager THERMAL IMAGER TiX640 3 4 5 1 2 hvh014 eps Item Description Color Video Camera Lens Laser Range Finder LED Video Light Color TFT Display Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 22: ...ieve professional results we recommend thoroughly reading the entire manual Table 1 6 Control Locations 3 4 5 6 7 8 9 10 1 2 hvh015 eps Item Description Focus rocker switch with autofocus Temperature Auto Multifunction 2 Multifunction 1 Save Joystick Power Escape Power LED Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 23: ...power supply by inserting the charged rechargeable lithium ion battery or by connecting the ac adapter to the thermal imager plug the 14 pin connector into the right LEMO socket with the red dot pointing to the top 2 Remove the cover of the SD card slot insert the SD card into the card slot and replace the cover 3 Remove the protective cap from the lens 4 Push The imager turns on and the Fluke log...

Страница 24: ...the Image Elements 1 4 5 3 2 8 9 7 6 hvh022 eps Item Description Item Description Camera menu Rechargeable battery SDHC card Temperature unit Status indications Date time Help line Camera status mode System information field Color scale with upper and lower limits Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 25: ...Push middle button for autofocus or to the left or to the right in order to set the focus for longer or shorter distances to the measuring object If the autofocus function is used a rectangle will be displayed in the center of the screen The distance setting is optimized taking the distance of the objects contained in the rectangle Setting the Temperature Range Push with a short press The thermogr...

Страница 26: ...ge or the upper and lower limits Max Min and the values can be input numerically as well In this the respective joystick and button functions are displayed to the left of the thermal image The respective input dialog for numerical input is displayed in the center of the field of view hvh030 jpg hvh031 jpg hvh032 jpg Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 27: ...t push of Enter Use a long push of Enter to continuously change the temperature scale automatically AUTO mode In AUTO mode shows on the right side of the image above the color palette The AUTO mode is terminated by any manual setting of Level Range Max Min hvh033 jpg hvh034 jpg hvh036 jpg hvh035 jpg Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 28: ...writing the data is indicated by the changing color of the map symbol in the line below the image right hand side When saving the camera control automatically activates the Live mode Quick Saving Immediately push the button completely The image is saved immediately the camera control then automatically re activates the Live mode Note Deviating from the factory setting described above the button ca...

Страница 29: ...four main menus can be selected by means of tabs located on the upper margin of the menu and identified with the corresponding symbols Image Menu File Menu Measure Menu Settings Menu Sub menus can be opened by using the button Enter on the respective menu item for example push the button in order to open the sub menu for manually setting the temperature range Settings made can be accepted using th...

Страница 30: ... that you attach the thermal imager to a tripod Caution Do not exceed the maximum penetration depth of the tripod thread 4 5 mm DIN 4503 Power Supply When using a rechargeable battery you must place the battery on the included adapter plate Push down the rechargeable battery until it engages Push the rechargeable battery slightly to the front towards the lens Please only use the genuine SONY recha...

Страница 31: ...amera corpus and turned clockwise until the red dot of the lens is aligned with the white dot of the camera Operation using the Gigabit Ethernet GigE Interface Please proceed as follows in order to connect the thermal imager to a PC notebook The accessories described are contained in the scope of delivery as an option The Ethernet cable is used in order to establish a connection to the Ethernet in...

Страница 32: ... or PC the power should be supplied using the ac adapter see Figure 1 3 with the 14 pin LEMO connector on right hand side socket hvh058 eps Figure 1 3 AC Adapter When the ac adapter is connected the camera is automatically supplied by the ac adapter and no longer by the rechargeable battery However the rechargeable battery is not charged at the same time Operation with Breakout Box Using the break...

Страница 33: ...ect the breakout box to the COM interface of the host computer with a commercially available cable 3 Connect the supplied ac adapter to the breakout box 4 Push the Power button on the backside of the camera to turn on the thermography system Table 1 8 Breakout Box 2 1 6 5 4 3 hvh061 eps Item Description Connecting cable for thermal imager 14 pin LEMO socket for ac adapter Terminal strip Trigger T1...

Страница 34: ...TiX620 TiX640 TiX660 TiX1000 Users Manual 1 30 Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 35: ...unction button on the top of the front camera handle Note All buttons can be used for multiple functions triggered either by half or full pressing and and or short or long pressing and The functions of the buttons and can be changed by setting the buttons see Chapter 3 Menus Furthermore the function of the buttons depends on the current mode of operation and depending on the aforementioned is disp...

Страница 36: ...Control Locations 3 4 5 6 7 8 9 10 1 2 hvh015 eps Item Description Focus rocker switch with autofocus Temperature Auto Multifunction 2 Multifunction 1 Save Joystick Power Escape Power LED Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 37: ... Non uniformity correction compensation long Menu Level Range For manually setting Level Range short Spot ON OFF If no AOI was created yet create spot 1 long Spot editor AOI settings short Laser ON OFF Mark and laser distance meter long Max Min ON OFF Global max min measurement On Off short IR Visual Light Image Switch over image mode long Color SW For manually setting Max Min halfway LED ON OFF P...

Страница 38: ... used in order to manually focus the infrared image change the focus to longer distance push left change the focus to shorter distance push right or to focus automatically center function of the focus rocker switch The Power button is used to turn on the thermal imager Initially the status LED on the left hand side above the button will start to flash green and the logo of the camera manufacturer ...

Страница 39: ...tment of the camera functions Help Lower screen area left Display of the current function Logo Lower right corner of the screen Manufacturer s logo Date time Screen center upper edge of screen Date and system time Camera status Upper right corner of the screen Current mode of operation Temperature scale Right edge of the screen Assignment of the colors shades of gray of the image to the temperatur...

Страница 40: ...SDHC card laser distance meter laser pointer photo LED GPS reception Information Screen area bottom left 1st line 2 nd line and 3 rd line Information indicators for GPS data latitude longitude satellites global emissivity ambient temperature path temperature relative humidity distance calibration range lens information zoom eps Te Tp rH Dist Cal FOV z Shop for Fluke products online at 1 888 610 76...

Страница 41: ...is mode is shown on the right hand side at the top of the screen In Live mode the current scene is shown as a false color representation of the temperature distribution IR image as a video image visible visible light image or as a superimposition of IR and visible light image IR Fusion technology The temperature scale of the false color representation of the IR image can be set automatically or ma...

Страница 42: ...he center function of the focus rocker switch Warning To prevent eye damage and personal injury Do not look into the laser Do not point laser directly at persons or animals or indirectly off reflective surfaces Use caution when the laser is on continuously Turn off the laser when it is not in use Permanent LaserSharp Auto Focus Go to the Laser menu and select LaserSharp Auto Focus Laser will conti...

Страница 43: ...commercially available SD and or SDHC cards up to a capacity of 32GB Depending on the detector format and the set memory format up to 25 000 IR images can be saved to one SDHC card this way Along with individual IR image thermal image sequences can be saved as digital raw data and video sequences The particular description of the camera settings for data storage can be found in Chapter 3 Menus Dep...

Страница 44: ...e line below the image right hand side When saving the camera control automatically activates the Live mode Quick Saving Using the thermal imager you can immediately save images in the Live mode or directly from the motion Immediately push the button completely The image is saved immediately the camera control then automatically re activates the Live mode Note Deviating from the factory setting de...

Страница 45: ...age section The menu can be navigated using the joystick settings are accepted using the joystick center button Enter The four main menus are located on the upper margin of the menu and can be selected by means of the corresponding symbols of the tabs hvh078 jpg hvh079 jpg hvh080 jpg hvh081 jpg Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 46: ...he upper menu in each case can be accessed directly by pushing from the very bottom and or Image can be selected directly by from Settings and or vice versa by Submenus can be opened by pushing the Enter button on the respective menu item for example to open the submenu for manual temperature range setting Changes performed to setting dialogs can be accepted using the joystick Enter button or or c...

Страница 47: ...low for a visual allocation of temperatures to the displayed scene by means of the false color representation of the thermal image Maximum and minimum values of the currently set temperature range are indicated by the corresponding figures above and below the arranged color palette Different modes can be selected for manually setting the temperature range in the Manual menu item Level Range Max Mi...

Страница 48: ...the upper and lower limits Max Min and the values can be input numerically as well In this the respective joystick and button functions are displayed to the left of the thermal image The respective input dialog for numerical input is displayed in the center of the field of view hvh087 jpg hvh088 jpg hvh089 jpg hvh090 jpg Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 49: ...cessed directly by the button functions Long and Long as set from the factory Mode Submenu In Live mode the thermal imager displays thermal images infrared images video images Digital images or the superimposition of both IR Fusion technology The options can be selected in the Mode menu which must be dropped down for this If an infrared image is currently displayed you can switch to Digital image ...

Страница 50: ...tivated in the Settings menu using the Extras menu item Digital image mode In the Digital image mode the camera internal digital photo channel is operated in video mode and displayed with a geometric resolution of 1024 x 720 pixels The option of saving photos with the available pixel resolution of 3264 x 2448 pixels 8 megapixels is set in the File menu using the Saving format menu item see Saving ...

Страница 51: ...he surface area In the color alarm high alarm and low alarm modes the displayed temperature range can be restricted blending depends on the temperature in the entire infrared image Color Alarm In the Color Alarm mode a partial temperature interval is defined within the set temperature range Partial areas the temperatures of which are within this interval are displayed as an infrared image in false...

Страница 52: ...gital magnification of the infrared image and the Digital image visible light image up to 32 fold The setting is made in the Setting menu using the Zoom menu item and is applicable to the currently displayed image in each case infrared image or visible light image A set magnification is indicated as the corresponding status symbol to the right below the image If the image was enlarged digitally th...

Страница 53: ...of gray of the false color representation to the corresponding temperatures is performed by using the palette shown on the right hand side margin of the screen In this the maximum value of the image area above and its minimum value below the palette serve the purpose of orientation for the temperature level The Image Palette menu item is used to open a dialog for selecting and setting predefined p...

Страница 54: ...eps Black Red Hot Metal Menthol Sepia Grayscale Rainbow Grayscale palette left and inverted representation right Palette containing 256 colors left and 16 colors right Grayscale Rainbow palette with temperature linear left and Ultra Contrast representation Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 55: ... default a linear curve is selected to represent the temperatures By activating this function it is possible to use a more differentiated resolution for the low temperature range when compared to the high temperature range The effects of the logarithmic representation are illustrated in Table 3 1 On the left hand side the palette with temperature linear representation is shown On the right hand si...

Страница 56: ...nts dialog to individually select the image elements The selection is made by setting the corresponding checkmark using the Enter button of the joystick The dialog can also be navigated with the joystick When selecting the Hide menu item all image elements of the graphical user interface are hidden at once If this function is activated a checkmark will be shown on the right side of the Hide menu i...

Страница 57: ...mage areas characterized by the same temperature in a defined temperature interval with the same representation color and or shade of gray With the help of the isotherms editor it is possible to create isotherms for differently sized temperature intervals The temperature ranges are identified with different colors The thermal imager supports a maximum of nine different isotherms hvh137 jpg hvh138 ...

Страница 58: ... joystick the limit values for each isotherm can be specified numerically in a dialog At this point changing the color of the isotherm is also possible The 15 special colors designed for the isotherms were selected in such a way that they can still be conceived as isotherm even when using a color palette Regardless of the aforementioned and for the purposes of unambiguous allocation of the tempera...

Страница 59: ...rmal imager to increase the available frame rate These can only be selected using the Format menu item In the event of partial images the number of transmitted pixels will be reduced This function requires specific calibration of the camera for the corresponding partial modes Due to the changed mode of operation of the detector in partial image mode deviating cycle regime shorter integration time ...

Страница 60: ...B with the file name AB062200 Therefore the filenames are numerated consecutively starting with 00 and up to 99 and as opposed to the directory are not equipped with any identification of the year in their names This way if the automatically generated directories and file names are completely exhausted a maximum number of 26 x 26 x 100 67 600 files will have been saved to 676 directories Please no...

Страница 61: ...y using the joystick Enter button On the right top next to the file list the preview image of the highlighted thermal image displays On the right bottom a photo shows from irb or jpg file If the thermal image saved as irb contains additional data the left upper corner of the preview image indicates the type of data V photo digital image Visible A audio file S image sequence serial file hvh163 jpg ...

Страница 62: ...ed large by using the joystick Enter button When the image is shown in its enlarged size the right left buttons can be used to navigate to the next and or previous image in the file list If a photo is saved in the irb format this photo is shown as a miniature version to the left of the thermal image Use to toggle the display between thermal image and photo Use to play a voice annotation contained ...

Страница 63: ...Real time series of single images thermal image and photo Autocapture video sequences thermal image digital image or IR Fusion as AVI Video The Saving format menu item can be used to set the data and formats to be saved see Saving Format Submenu on page 3 23 Real time saving The maximum writing speed possible for real time saving depends on the detector and the geometric resolution as well as on t...

Страница 64: ...s the temperature allocation using false color representation is sufficient In this case the currently displayed image area including all selected image elements for the setting see Elements Submenu on page 3 12 are saved as a video sequence AVI file and can be displayed with generally available player software media player The menu to the left of the image as well as the help and status symbol li...

Страница 65: ...and Count the duration of series saving otherwise calculated from the values for interval and number of images Count can also be defined Depending on the selected saving format the minimum time interval is shown When opening the settings dialog using the joystick Enter button in the Autocapture submenu date and time of the camera clock are accepted as start time After having accepted all settings ...

Страница 66: ...line The keyboard can simply be navigated with the joystick Capital and lower case letters are switched similarly to a computer keyboard There is an additional keyboard page for numbers and selected special characters A maximum of 50 characters can be entered The number of the current character is indicated on the upper margin of the keyboard The keyboard input is finished by pushing the button an...

Страница 67: ... by pushing the joystick Enter button to delete all data from the card and to re format the card After the card is formatted all data is deleted irrevocably Note This process cannot be undone Saving Format Submenu Using the Saving format menu item data to be saved in addition to the thermal image and its format can be selected and furthermore settings to be made in connection with the process of s...

Страница 68: ... 448 Voice annotation Saving the audio files irb thermal image and audio in one file wav audio in separate file Measurement definitions Saving measurement definitions irb no selection possible Screenshot Graphics file screenshot png no selection possible Autofocus Automatic focusing is performed before saving NA Compensation NUC Non Uniformity Correction is performed before saving NA Light The pho...

Страница 69: ...value are consistently updated within the image Regardless of the palette selected for false color representation the maximum is red and the minimum is blue The spot temperature values are only displayed within the central image area where no other system indications are displayed These indications are not contained in the thermal images saved digitally but can be saved when saving the display as ...

Страница 70: ...lso be displayed for in each case along with the average value hvh185 jpg The following shapes of the measuring objects can be selected point P line L polygon line PL rectangle R ellipse polygon PG In order to create a new AOI you must initially open the Editor submenu and select the required format of the measuring object at New Measuring point P The shape of the AOI and the index of the measurin...

Страница 71: ...rminal points or by synchronously moving both terminal points simultaneously The respective active point and or both points are also marked in red If the button is pressed in the editor the settings dialog for displaying the measured values is shown For surface areas and lines the spot temperature can be shown as values and as spot in the image along with the average value Furthermore the identifi...

Страница 72: ... with the option of deleting individual AOIs in the respective editor by using the button all created AOIs can be deleted simultaneously using the corresponding dialog to be confirmed hvh193 jpg hvh194 jpg Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 73: ...eated using the button Polygon PG The thermal imager supports polygon planes with a maximum of 11 points the position of which can be defined freely After having defined the position of a first point a new point is created every time the Enter button is pressed longer whereby this new point can be moved to its target position Once more than one point is created the Enter button can be pressed shor...

Страница 74: ...TiX620 TiX640 TiX660 TiX1000 Users Manual 3 30 hvh202 jpg hvh203 jpg hvh204 jpg hvh205 jp hvh206 jp hvh207 jpg Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 75: ...mission and distance in accordance with the current measuring situation These values are stored with each thermal image and can be displayed and changed if required during subsequent editing of the IR images using the analysis software Taking into consideration the real measuring conditions particularly the surface properties of an measuring object and the temperature level of the environment tran...

Страница 76: ...ecise temperature measurement To properly enter the respective correction parameters exact knowledge of the real properties of the measuring object as well as of the ambient conditions and the measurement setup is required The correction parameters are accepted globally for the entire image hvh211 jpg hvh212 jpg Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 77: ...ion dew and distance should be defined and taken into consideration The Material option provides an alphabetically sorted collection of the emissivity of different materials within the framework of which the different surface conditions are partially taken into consideration When material and condition status are selected the emissivity of the selected material is accepted as global emissivity hvh...

Страница 78: ...d within the IR image This is suitable in the event of stationary measurement setups where the distance between camera and measuring object does not change and can be determined easily If the Automatic option is selected the distance calculated from the process of adjusting the focus is displayed after each manual or automatic focusing and saved within the thermal image The laser distance meter in...

Страница 79: ...er with the thermal image height speed and bearing Note GPS functions work most effectively when outdoors Allow up to 20 minutes for the imager to find satellites Laser Submenu The laser distance meter integrated into the thermal imager allows for precise distance measurement depending on the target size the angle and the surface properties up to a distance of approx 70 m Along with the activation...

Страница 80: ...are setting regarding the thermal imager hvh222 jpg Calibration Submenu The thermal imager is calibrated to measure temperatures in the range of 40 1 200 C Depending on the equipment the total measuring range and the individual ranges of your device may deviate from this standard calibration The actually available ranges can be found in the Calibration menu item hvh223 jpg Depending on the object ...

Страница 81: ...the automatic measuring range setting factory setting Extras Submenu hvh224 jpg The settings that can be selected in the Extras menu item activate the following functions Premium A camera internal compensation NUC is performed before each saving Special Saving is performed with activated image filter RE Super Resolution To save the image the hardware based microscan procedure is activated recordin...

Страница 82: ...cts AVG The average value is determined before the image is saved TBV A specific filter is used to save the image EverSharp The camera will take all images using EverSharp mode Note You can see images taken with EverSharp in SmartView software Automatic Submenu hvh225 jpg The Automatic menu item can be used to select different variants for the automatic adaptation of the shown temperature range to...

Страница 83: ... set representation range follows the maximum temperature value of the current scene The lower limit of the shown temperature range remains constant The mode set in each case in the Automatic menu item is deactivated by every manual change to the temperature scale or when the Auto Mode Span function is triggered for the first time Compensation Submenu To implement the specified measurement accurac...

Страница 84: ...ng on the change of the device temperature over the course of the first 5 minutes During this time the time specified for the Interval option is ineffective When switching the compensation to the Object option the function is referenced to the current scene As a consequence this results in a differential representation referring to the scene present at the moment of compensation This way it is pos...

Страница 85: ...g to the scene Compensation long NUC Non Uniformity Correction Compensation long NUC Reset NUC Compensation range adaptation NUC and temperature scale in accordance with the scene Level range menu For manually setting Level range Max Min menu For manually setting Maximum Minimum Laser on off Laser distance meter laser pointer on off Light on off halfway Photo light on off Real time saving Start st...

Страница 86: ... image Switch over image mode infrared image Digital image Isotherms on off Show hide isotherms Minimum on off Show hide global minimum Maximum on off Show hide global maximum Minimum and Maximum on off long Show hide global Minimum and Maximum Switch over palette Next palette Invert palette Invert palette Grayscale palette color Switch over color grayscale palette Freeze image completely Stop the...

Страница 87: ...t Submenu The Digital Alarm Output menu item can be used to define conditions the fulfillment of which will trigger the camera to perform actions hvh235 jpg hvh236 jpg The activated digital alarm output function is indicated in the tool bar below the logo by means of a symbol This indication is made regardless of whether an alarm condition is fulfilled Shop for Fluke products online at 1 888 610 7...

Страница 88: ...in Saving format COM Alarm indication via the RS232 interface Audio Output of an acoustic alarm signal Digital out 1 Alarm signal at digital output 1 Digital out 2 Alarm signal at digital output 2 Configuration Submenu You can save your individual device settings as device configuration in the thermal imager This way you can configure and if required reload user and or application profiles matchin...

Страница 89: ...Display Menus Settings Menu 3 3 45 hvh241 jpg hvh242 jpg hvh243 jpg hvh244 jpg Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 90: ...tings all previously made system settings will be undone If settings must possibly be re used at a later point in time we recommend saving a user configuration beforehand System Menu The System menu item contains the settings and information about the basic functions of the thermal imager Along with the settings for language date and time which as a rule must only be configured rarely it is possib...

Страница 91: ...ver you can make either Display or viewfinder Finder as the active display element hvh246 jpg The brightness values of display and viewfinder can be set independently using the levels Bright Medium and Dimmed When the ambient lighting conditions are normal the brightness setting Medium is absolutely sufficient for the display In dark conditions the setting Dimmed should be selected The DVI D outpu...

Страница 92: ...vailable in each case depend on the equipment The units for the distance and for the temperature can also be set hvh247 jpg Date and Time Submenu Setting the date and the time corresponds to the procedure usual for PCs we recommend entering the information in the corresponding dialogs on a per line basis from the top to the bottom hvh248 jpg Shop for Fluke products online at 1 888 610 7664 www MyF...

Страница 93: ...and Small Particularly in the event of a large font size a part of the text shown in the menus is no longer displayed completely because the available space is insufficient However when navigating to the corresponding menu item this menu item is displayed completely even when it exceeds the menu width hvh249 jpg hvh250 jpg hvh251 jpg hvh252 jpg Shop for Fluke products online at 1 888 610 7664 www ...

Страница 94: ...te from the Settings menu directly to the Image menu using and menu cycle Horizontal You can also navigate from the lower menu line directly to the first menu line using and menu cycle Vertical To combine both variants you can select the Allover option in the menu cycle hvh253 jpg In order to play voice annotations as well as alarm and system signals the volume can be set to the three levels Quiet...

Страница 95: ...leenex in combination with 96 ethanol Please contact the manufacturer in the event of strong contaminations Caution When the lens is removed lens change the aperture of the camera housing must be protected against any kind of contact with the inner components It must be ensured that no dirt can penetrate the inside of the camera Interventions of any kind into the inside of the thermography camera ...

Страница 96: ... disposed of specifically when the device is at the end of its use The manufacturer offers to take back the thermal imager product from the customer in order to ensure that the device is disposed of in an environmentally friendly manner when it is at the end of its use In this case see How to Contact Fluke for more information Service According to the manufacturer s recommendation the thermal imag...

Страница 97: ...sassemble or crush battery cells and battery packs Do not keep cells or batteries in a container where the terminals can be shorted Do not put battery cells and battery packs near heat or fire Do not put in sunlight Warning For safe operation and maintenance of the Product Repair the Product before use if the battery leaks Be sure that the battery polarity is correct to prevent battery leakage Use...

Отзывы: