S
I M P L I
F
I B E R
ENGLISH -
27
5. Press, hold and release the
button to
set and save the
new reference
value. The refer-
ence value will be
displayed.
6. Disconnect the Launch Cable from the
S
IMPLI
F
IBER
Meter.
Measuring Loss using
Method B
When Method B was used to
set the reference, proceed as
follows:
1. Do not disconnect the
launch cable from the
S
IMPLI
F
IBER
Source unit.
2. Connect the fiber to be
measured between the
S
IMPLI
F
IBER
Meter output and
the launch cable that is
attached to S
IMPLI
F
IBER
Source.
An extra coupler is needed.
3. S
IMPLI
F
IBER
Meter will
immediately report the loss
in dB.
2m Launch Cable
SimpliFiber
Source
METHOD B
Cable Under T
est
SimpliFiber
Meter