Fluke ScopeMeter 125 Скачать руководство пользователя страница 1

®

 

Fluke 125 

Industrial ScopeMeter 

Getting Started

 

 

 

 

 

GB 

Dec 2006 
© 2006 Fluke Corporation, All rights reserved. Printed in The Netherlands 
All product names are trademarks of their respective companies. 

Содержание ScopeMeter 125

Страница 1: ...Fluke 125 Industrial ScopeMeter Getting Started GB Dec 2006 2006 Fluke Corporation All rights reserved Printed in The Netherlands All product names are trademarks of their respective companies...

Страница 2: ...Contents of the Fluke 125 Test Tool Kit 2x 2x 3x 1 9 3 2 4 5 6 7 8 10 11 14 12 13 15 16 8 Figure 1 Fluke 125 Test Tool Kit...

Страница 3: ...he U S A and Canada 31 40 2675200 in Europe 1 425 446 5500 from other countries Safety Information Read First The Fluke 125 ScopeMeter Test Tool hereafter referred to as Test Tool complies with ANSI I...

Страница 4: ...8907 808 is not for use in North America A line plug adapter complying with the applicable National Requirements may be provided to alter the blade configurations for a specific country Warning To avo...

Страница 5: ...the test leads for mechanical damage and replace damaged test leads Whenever it is likely that safety has been impaired the Test Tool must be turned off and disconnected from the line power The matte...

Страница 6: ...ss and contrast Open the LIGHT CONTRAST button bar Press LIGHT Dim Brighten the backlight Press CONTRAST Adjust the Contrast of the display Reading the Screen The screen is divided into three areas th...

Страница 7: ...king Menu Selections Selection of a function in the menu is done as follows A menu pops up after operation of for instance the MENU key Use the arrow keys to highlight for example the SCOPE METER mode...

Страница 8: ...ack Ground Lead at Input COM Common For low frequency measurements and high signal levels use the Black COM Common Input as single ground Figure 3 shows this For measurements at higher frequencies up...

Страница 9: ...nput A to the unknown signal to be measured Perform an Auto Set Certain details of the waveform can be made visible by manually changing amplitude time base waveform position and triggering How to do...

Страница 10: ...has now moved to the smaller Secondary Reading Position Figure 5 shows this Then choose Peak to Peak Reading for Input B Open the B MEASUREMENTS menu Highlight ON Turn INPUT B on Highlight PEAK Open...

Страница 11: ...Trigger Identifier Trigger Level and the Trigger Slope can be adjusted to your personal taste This may help to get certain signal details within the viewing area Enables the arrow keys for Trigger Le...

Страница 12: ...F1 F2 and F3 give access to submenus INPUT PROBE SELECT for selection of the correct probe type PROBE AC ADJUST for adjustment of 10 1 voltage probes other than the probe supplied with Fluke 125 This...

Страница 13: ...ate when valid triggers occur SINGLE can be used to catch single events ROLL is useful for monitoring lower frequency waveforms AUTO RANGE 15Hz 1Hz selection of Auto Set on signals 15 Hz fast response...

Страница 14: ...obe type Harmonics Screen Softkey Functions The harmonics screen shows a softkey button bar like the one shown below The harmonics screen F1 F4 key functions are Show the voltage VOLT harmonics the cu...

Страница 15: ...ind a bus type indicate that a submenu will follow on this selection Open the MODBUS submenu Highlight IEA 232 RS 232 Press ENTER to confirm the selection Bus Health Screen The following icons are use...

Страница 16: ...reading Display the signal eye pattern Setting up the Limits To set up the test limits of the current bus type do the following Select the SETUP LIMITS menu from the bus health screen Select the signa...

Страница 17: ...ction of time Turning the Trendplot Mode On Off Open the application mode menu Highlight TRENDPLOT Start a Trendplot Trendplot Screen Softkey Functions Stop the Trendplot TREND RESTART Start a new Tre...

Страница 18: ...of messages can be selected in this submenu VERSION CAL shows version and calibration information SAVE PRINT Functions Show the PRINT SCREEN RECALL DELETE and SAVE key labels PRINT SCREEN The active s...

Отзывы: