Introduction

The PRV240FS Proving Unit (the Product) is an 

electronic voltage source. This Product provides 

a safe and easy method to verify proper operation 

of the T6-600/T6-1000 Electrical Tester with 

FieldSense technology or other test tools. Use 

it to verify either an energized source or a de-

energized source. Also use it in cases where no 

known voltage source is available to verify a test 

tool. 
The Product does not require personal protective 

equipment (PPE) unless your environment 

requires minimal PPE such as a hard hat, safety 

glasses, or ear plugs.

How to Contact Fluke

To contact Fluke, call one of the following 

telephone numbers:

 

Technical Support USA: 1-800-44-FLUKE  

(1-800-443-5853)

 

Calibration/Repair USA: 1-888-99-FLUKE  

(1-888-993-5853)

 

Canada: 1-800-36-FLUKE (1-800-363-5853)

 

Europe: +31 402-675-200

 

Japan: +81-3-6714-3114

 

China: +86-400-921-0835

 

Singapore: +65-6799-5566

 

Anywhere in the world: +1-425-446-5500

Or, visit Fluke's website at 

www.fluke.com

.

To register your product, visit  

http://register.fluke.com

.

To view, print, or download the latest manual 

supplement, visit  

http://us.fluke.com/usen/support/manuals

.

Safety

Warning

 identifies conditions and procedures 

that are dangerous to the user.



 Warning

To prevent possible electrical shock, fire, 

or personal injury:

 

● Read all safety information before you 

use the Product.

 

● Carefully read all instructions.

 

● Do not alter the Product and use only as 

specified, or the protection supplied by 

the Product can be compromised.

 

● Do not touch voltages >30 V ac rms, 

42 V ac peak, or 60 V dc.

 

● Do not use the Product around 

explosive gas, vapor, or in damp or wet 

environments.

PN 4919689  September 2017

© 2017 Fluke Corporation. All rights reserved.  

Product specifications are subject to change without notice.  

All product names are trademarks of their respective companies.  

 

● Do not use the Product if it operates 

incorrectly.

 

● Examine the case before you use the 

Product. Look for cracks or missing 

plastic. Carefully look at the insulation 

around the terminals.

 

● Do not use the Product if it is altered or 

damaged.

 

● Remove the batteries if the Product is 

not used for an extended period of time, 

or if stored in temperatures above 50 °C. 

If the batteries are not removed, battery 

leakage can damage the Product.

 

● You must close and lock the battery 

door before you operate the Product.

Symbols

Symbols used in the instructions or on the Product 

are shown in Table 1.

Table 1. Symbols

Symbol

Definition

Consult user documentation.

WARNING. HAZARDOUS VOLTAGE. 

Risk of electric shock.

WARNING. RISK OF DANGER.

Battery

FieldSense Measurement: Fluke  

voltage/current sensing technique.

Certified by CSA Group to North 

American safety standards.

Conforms to relevant Australian EMC 

standards.

Conforms to European Union directives.

Conforms to relevant South Korean EMC 

Standards.

This product complies with the WEEE 

Directive marking requirements. The 

affixed label indicates that you must not 

discard this electrical/electronic product 

in domestic household waste. Product 

Category: With reference to the equipment 

types in the WEEE Directive Annex I, 

this product is classed as category 9 

"Monitoring and Control Instrumentation" 

product. Do not dispose of this product as 

unsorted municipal waste.

Operation

Table 2 is a list of the controls and interface of 

the Product. See Figure 1 for the location of each 

item.

Table 2. Product Overview

Item

Description

A

Function selection

B

+ Terminal 

C

AC/DC LED

 Terminal

E

Test Lead Ground Contact

F

Test Lead Ground Contact LED

G

Fork saddle

H

Finger Ground Contact LED

I

Finger Ground Contact

FieldSense Measurement without Test Lead

Before verification, set up the T6 for a FieldSense 

measurement without the test leads. See the 

T6

 

Quick Reference Guide

.  

To verify measurement:

1.  Move the switch to the FieldSense position. 

See Figure 3.

2.  Insert the T6 fork into position on the Product.

3.  Push and hold the finger ground contact to 

activate the Product.

 

The Product LED turns green and the T6 

display shows a 240 V measurement.

FieldSense Measurement with Ground Lead

Before verification, set up the T6 for a FieldSense 

measurement with the ground lead. See the 

T6

 

Quick Reference Guide

To verify measurement:

1.  Move the switch to the FieldSense position. 

See Figure 4.

2.  Insert the T6 fork into position on the Product.
3.  Place the black test lead from the test tool 

into the test lead ground contact terminal and 

press down firmly. 

 

The Product LED turns green and the T6 

display shows a 240 V measurement.

AC/DC Measurement

Before verification, set up the T6 or other test tool 

for ac/dc measurement with the test leads. 
To verify measurement:

1.  Move the switch to the AC or DC position. 

See Figure 5.

2.  Place the red test lead from the test tool into 

the (+) terminal and press down firmly.

3.  Place the black test lead from the test tool 

into the (-) terminal and press down firmly. 

 

The Product

 

LED turns green and the T6 

display shows a 240 V measurement.

Battery Replacement

Push the finger ground contact button to check the 

battery condition. The finger ground contact LED 

turns green to show good battery condition. If the 

LED does not turn on, replace the batteries.

 



 Warning

To prevent possible electrical shock, fire, or 

personal injury:

 

● Do not operate the Product with covers 

removed or the case open. Hazardous 

voltage exposure is possible.

 

● Repair the Product before use if the battery 

leaks.

 

● Have an approved technician repair the 

Product.

To replace the batteries:

1.  Turn the battery-door latch until the unlock 

symbol aligns with the arrow. See Figure 2.

2.  Lift off the battery door.

3.  Insert or replace the four AA batteries. Use 

the correct battery orientation.

4.  Install the battery door.

5.  Turn the battery-door latch until the locked 

symbol aligns with the arrow.

Specifications

Output voltage

240 V ac rms or dc ........... ±10 % 

1 MΩ

LED power indicator

 ......... Turns on when output voltage is 

present

Battery

 ...................................

4 x AA Alkaline batteries NEDA 

15 A IEC LR6

Battery life

 .............................

3 hr based on a 10 s test cycle or 

1100 tests

Operating temperature

 ..... -10 °C to +50 °C

Operating humidity

 ........... 0 % to 90 % (0 °C to 35 °C)

0 % to 70 % (35 °C to 55 °C)

Operating altitude

 ............. 2000 m

Dimensions

 ....................... 11.7 cm x 7.4 cm x 4.5 cm

(4.6 in x 2.9 in x 1.75 in)

Weight

 ................................ 0.32 kg (12 oz) 

includes batteries

Safety

General ............................ IEC 61010-1, Pollution Degree 2
Measurement ................... IEC 61010-2-030

240 Vrms/240 Vdc

Electromagnetic Compatibility (EMC)

  International ...................... IEC 61326-1: Controlled 

Electromagnetic Environment
CISPR 11: Group 1, Class A

Group 1: Equipment has intentionally generated and/or uses 

conductively-coupled radio frequency energy that is necessary 

for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments 

other than domestic and those directly connected to a low-

voltage power supply network that supplies buildings used 

for domestic purposes. There may be potential difficulties in 

ensuring electromagnetic compatibility in other environments 

due to conducted and radiated disturbances. 
Caution: This equipment is not intended for use in residential 

environments and may not provide adequate protection to 

radio reception in such environments.
Emissions that exceed the levels required by CISPR 11 can 

occur when the equipment is connected to a test object.

Korea (KCC) ....................... Class A Equipment (Industrial 

Broadcasting & Communication 

Equipment)

Class A: Equipment meets requirements for industrial 

electromagnetic wave equipment and the seller or user 

should take notice of it. This equipment is intended for use in 

business environments and not to be used in homes.

USA (FCC) .......................... 47 CFR 15 subpart B. This 

product is considered an exempt 

device per clause 15.103.

LIMITED WARRANTY AND LIMITATION OF LIABILITY

This Fluke product will be free from defects in material 

and workmanship for one year from the date of purchase. 

This warranty does not cover fuses, disposable batteries, 

or damage from accident, neglect, misuse, alteration, 

contamination, or abnormal conditions of operation or 

handling. Resellers are not authorized to extend any other 

warranty on Fluke’s behalf. To obtain service during the 

warranty period, contact your nearest Fluke authorized service 

center to obtain return authorization information, then send 

the product to that Service Center with a description of the 

problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER 

WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR 

PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT 

LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR 

CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM 

ANY CAUSE OR THEORY. Since some states or countries 

do not allow the exclusion or limitation of an implied warranty 

or of incidental or consequential damages, this limitation of 

liability may not apply to you.

Fluke Corporation

Fluke Europe B.V.

P.O. Box 9090

P.O. Box 1186

Everett, WA  98206-9090

5602 BD Eindhoven

U.S.A.

The Netherlands

11/99

Fluke Corporation certifies this Product was tested and 

verified with applicable calibration procedures during the 

manufacturing process. Fluke’s quality system controls these 

procedures.
The instruments used during the testing and calibration of 

this Product are traceable to SI units through internationally 

recognized measurement standards.
This document is not a certificate of calibration or traceability.

To obtain a certificate of calibration contact the nearest 

Fluke service center to process an order to have your 

Product returned for calibration. A nominal fee is charged for 

calibration service.

All manuals and user guides at all-guides.com

all-guides.com

Отзывы: