Powering the Tester
W
Warning
*
Read the safety information at the beginning of
Chapter 2 before using the tester.
You can power the tester with the ac adapter included or
with the removable lithium ion battery pack.
Press
I
to turn the tester on.
Charging the Battery
Before you rely on battery power for the first time, charge
the battery for about 2 hours with the tester turned off.
You can also charge the battery when it is detached from
the tester, as shown in Figure 1-1.
A fully-charged battery lasts about 8 hours during typical
use. The battery typically takes about 4 hours to fully
charge when the tester is turned off.
Notes
You do not need to fully discharge the battery
before recharging it.
The battery will not charge if its temperature is
outside the range of 32 °F to 113 °F (0 °C to
45 °C).
Checking the Battery Status
Many of the tester’s screens show a battery status icon
(
) near the lower-right corner.
To see more information about the battery status press
F
; then select Battery Status. Press
H
for detailed
information about the battery status screen.
The battery pack has its own LED power gauge, which you
can activate by pressing the small button near the LEDs, as
shown in Figure 1-1. The LEDs indicate the charge level as
follows:
•
No LEDs lit or 1 flashing:
<
10 % charge
•
1 LED lit: 10 % to 33 % charge
•
2 LEDs lit: 33 % to 67 % charge
•
3 LEDs lit:
>
67 % charge
Содержание OF-500-01 OptiFiber
Страница 4: ......
Страница 18: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook xiv...
Страница 29: ...Getting Acquainted Powering the Tester 1 9 1 ajt20f eps Figure 1 1 Battery Pack Feature...
Страница 31: ...Getting Acquainted Verifying Operation 1 11 1 ajt56f eps Figure 1 2 Removing the Module...
Страница 48: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28...
Страница 76: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 2 28...
Страница 95: ...Using the OTDR Running the OTDR Test 3 19 3 ajt33f eps Figure 3 12 Connecting the OTDR to Spooled Cable...
Страница 110: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 3 34...
Страница 117: ...Using the OTDR Comparing OTDR Traces 3 41 3 ajt68f eps Figure 3 16 Comparing OTDR Traces F G H C D E A B...
Страница 132: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 3 56...
Страница 135: ...Using the ChannelMap Function Running the Test 4 3 4 ajt55f eps Figure 4 2 ChannelMap Test Connections...
Страница 138: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6...
Страница 141: ...Using the FaultMap Function Running the Test 5 3 5 ajt55f eps Figure 5 2 FaultMap Test Connections Channel to be tested...
Страница 144: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 5 6...
Страница 155: ...Using the Loss Length Option Changing the Connector Adapter 7 3 7 ajt61f eps Figure 7 2 Changing the Connector Adapter...
Страница 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 44...
Страница 200: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 8 4 ajt03f eps Figure 8 2 Using the Visual Fault Locator...
Страница 216: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 10 10...
Страница 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 12 30...
Страница 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook A 2...
Страница 259: ...Loss Test Methods 1 Jumper Method B 3 B ajt59f eps Figure B 1 1 Jumper Reference and Test Connections singlemode shown...
Страница 261: ...Loss Test Methods 2 Jumper Method B 5 B ajt58f eps Figure B 2 2 Jumper Reference and Test Connections singlemode shown...
Страница 268: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2...
Страница 278: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 10 OTDR 3 11 WEAK SIGNAL 3 35 Z TEST METHOD B 8 zoom 3 27...