MultiFiber Pro Optical Power Meter and Fiber Test Kits
Users Manual
54
GUE15.EPS
Figure B-13. Connections for Loss Measurements on Multimode Permanent Links with Pinned MTP/MPO Connectors
when Links are Used with Corning Plug & Play
™
Universal Systems
12 11 10 9 8 7 6 5 4 3 2 1
1 2 3 4 5 6 7 8 9 10 11 12
Meter
Source
Type B
Fiber link
Type B
Test cord 2
Pinned/Unpinned
Type A adapter
Key-up/Key-down
Unpinned/Pinned
Type B adapter
Key-up/
Key-up
Type B
Test cord 1
Pinned/Pinned
Pinned
Type A adapter
Key-up/
Key-down
Pinned
Type B
Test cord 3
Unpinned/Unpinned
Source channel:
Meter channel:
Caution
Do not disconnect test cord 1 from
the source after you set the
reference.
Meter shows
POLARITY B