![Fluke MultiFiber Pro Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/fluke/multifiber-pro/multifiber-pro_user-manual_2309935045.webp)
Specifications
35
Sources
Specifications apply at 23ºC (73ºF), unless otherwise noted.
850 nm Source
1310 nm Source
1550 nm Source
Emitter type
LED
Laser
Wavelength
±30 nm
1310 nm ±20 nm
1550 nm ±20 nm
Spectral width (FWHM)
50 nm (typical)
2 nm typical, 5 nm maximum
Minimum output power
-24 dBm
-1 dBm
Power output stability
±0.1 dB over 8 hours
4
±0.25 dB over 8 hours
5
Laser safety
IEC 60825-1:Class 1
Encircled flux
Meets TIA 455-526-14B, ISO/IEC 14763-3,
and IEC 61280-4-1 for 50/125
μ
m at the
source’s optical connector.
NA
Optical connector
MTP/MPO interface for 12-fiber, unpinned
plugs. Compatible with 62.5
μ
m and 50
μ
m
fibers, non-APC only. Connector has a self-
closing, protective cover.
MTP/MPO interface for 12-fiber,
unpinned plugs. Compatible with 9
μ
m
fibers, APC only. Connector has a self-
closing, protective cover.
4. 23°C, after 10 minutes of warm-up time.
5. 23°C, after 15 minutes of warm-up time.