MP
Series
Users Manual, Rev. 1.0, Apr 2021
52
7.8 Ethernet Cable (A-CB-xx-M12-W04-xx)
The Ethernet cable comes with a four-pin male M12 D-coded connector, assigned to the scanners rear female
M12 connector. The corresponding end of the Ethernet cable is equipped with a general RJ45 snap-in connector.
The LT version of the cable is PUR coated and withstands ambient temperatures up to 80°C (176°F).
The HT version is Teflon coated and withstands ambient temperatures up to 180°C (356°F).
Figure 7-6: Ethernet Cable
Figure 7-7: Pin Assignment
RJ45 Plug
M12 Plug
Table 7-4: Available Ethernet Cables
P/N
Length
Ambient Temperature
A-CB-LT-M12-W04-07
7.5 m (25 ft)
80°C (176°F)
A-CB-LT-M12-W04-25
25 m (82 ft)
80°C (176°F)
A-CB-LT-M12-W04-50
50 m (164 ft)
80°C (176°F)
A-CB-HT-M12-W04-07
7.5 m (25 ft)
180°C (356°F)
A-CB-HT-M12-W04-10
10 m (33 ft)
180°C (356°F)
1
2
3
6
1
3
2
4
Содержание MP Series
Страница 16: ...MP Series Users Manual Rev 1 0 Apr 2021 16 1024 pixel 80 Hz scan rate Scan Angle FOV All models 90 ...
Страница 18: ...MP Series Users Manual Rev 1 0 Apr 2021 18 2 2 1 2 Far Focus Figure 2 2 Optical Diagrams Far Focus ...
Страница 37: ...Installation Ethernet 37 5 5 Close the dialog box by pressing on Save ...