Panel 1 

®

 

i410/i1010 

AC/DC Current Clamp 

Instruction Sheet 

Safety Information 

XW

 

Read First: Safety Information 

To ensure safe operation and service of the 

current clamp, follow these instructions: 

 

Read all operating instructions before use and follow all 

safety instructions. 

 

Use the Current Clamp only as specified in the 

operating instructions, otherwise the clamp’s safety 

features may not protect you. 

 

Adhere to local and national safety codes. Individual 

protective equipment must be used to prevent shock 

and arc blast injury where hazardous live conductors 

are exposed. 

 

Do not hold the Current Clamp anywhere beyond the 

tactile barrier. See Features and Connections. 

 

Before each use, inspect the Current Clamp. Look for 

cracks or missing portions of the clamp housing or 

output cable insulation. Also look for loose or weakened 

components. Pay particular attention to the insulation 

surrounding the jaws. 

 

Never use the clamp on a circuit with voltages higher 

than 600 V (CAT. III) or a frequency higher than 400 Hz 

(i410) or 2 kHz (i1010). 

 

CAT III equipment is designed to protect against 

transients in equipment in fixed equipment 

installations, such as distribution panels, feeders and 

short branch circuits, and lighting systems in large 

buildings. 

 

Use extreme caution when working around bare 

conductors or bus bars. Contact with the conductor 

could result in electric shock. 

 

Use caution when working with voltages above 60 V dc, 

30 V ac rms or 42 V ac peak. Such voltages pose a 

shock hazard.

 

PN 617677  September 1996, Rev.2, 6/05 

1996-2005 Fluke Corporation. All rights reserved. Printed in Thailand. 

1.888.610.7664 

[email protected]

Fluke-Direct

.com

Содержание i1010

Страница 1: ...k for cracks or missing portions of the clamp housing or output cable insulation Also look for loose or weakened components Pay particular attention to the insulation surrounding the jaws Never use th...

Страница 2: ...A Jaw Lever B Jaw Centering Marks C ON Indicator D ON OFF Switch E Zero Adjust F Battery Access G Output Cable H Tactile Barrier Minimum voltmeter requirements Accepts safety shrouded banana plugs Ca...

Страница 3: ...A 600V CAT 600V 600A CLAMP METER i410 ZERO A CAT 600V 600A 600V mV 76 TRUE RMS MULTIMETER ar002i eps A Connect to voltmeter B Select mV dc C Set ON D Adjust ZERO jaws empty ZERO A ar006i eps E Clamp a...

Страница 4: ...ER i410 ZERO A 600 V CAT 600V 600A CLA MP ME TER i4 10 ZE RO A 60 0V CA T 60 0V 60 0A V 76 TRUE RMS MULTIMETER ar003i eps A Connect to voltmeter B Select mV ac or V ac but resolution may be limited to...

Страница 5: ...V 600A 600V V 76 TRUE RMS MULTIMETER ar004i eps A Set OFF B Select V dc C 7 0 V dc replace battery Voltmeter input impedance 1 M Replacing the Battery For specified battery life use an alkaline batter...

Страница 6: ...alified service technician For service information contact your nearest Fluke dealer or service center Symbols May be used on HAZARDOUS LIVE conductors T Equipment protected by double or reinforced in...

Страница 7: ...18 in diameter 2 ea 25 mm 0 98 in diameter Load Impedance 1 M 100 pF Temperature Coefficient 0 05 x accuracy per C 0 C 18 C 28 C 50 C Size 209 mm x 78 mm x 48 mm 3 09 in x 8 21 in x 1 87 in Weight 0...

Страница 8: ...iod To obtain warranty service contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the di...

Отзывы: