Autotest in Smart Remote Mode
1
Turn on the tester and smart remote and let them sit for
5 minutes. Allow additional time if the modules have
been stored above or below ambient temperature.
2
Turn the rotary switch to
SETUP
, then select
Fiber
. Set
the following on the
Fiber
tabs (press
C
to see other
tabs):
•
Fiber Type:
Select the fiber type to be tested.
•
Test Limit
: Select the test limit required for the job.
Press
J
More
to see other lists of limits.
•
Remote End Setup
: Set to
Smart Remote
.
•
Bi-directional
: Enable this if you are required to test
the fiber in both directions.
•
Number of Adapters
and
Number of Splices
: Enter
the number of adapters and splices that will be
added to each direction of the fiber path after the
reference is set.
•
Connector Type:
Select the connector type used in
the cabling to be tested. Select
General
if the exact
type is not listed.
•
Test Method
: Refers to the number of adapters
represented in the loss results. Select
Method B
if
you use the reference and test connections shown
in this manual.
3
Turn the rotary switch to
SPECIAL FUNCTIONS
, then
select
Set Reference.
If both a fiber module and a
twisted pair or coaxial adapter are attached, select
Fiber
Module
next.
4
The
Set Reference
screen shows reference connections
for the test method you selected. Figure 8 shows
connections for Method B. Clean the connectors on the
testers and reference test cords, connect the tester and
smart remote; then press
P
.
See Table 2 on page 15 for details on settings.
-continued-
Содержание DTX-GFM2
Страница 15: ...Installing the Connector Adapter 9 amd99f eps Figure 4 Installing the Connector Adapter...
Страница 29: ...Certifying Fiber Cabling 23 amd145f eps Figure 8 Smart Remote Mode Reference Connections Method B...
Страница 31: ...Certifying Fiber Cabling 25 amd146f eps Figure 9 Smart Remote Mode Test Connections Method B...
Страница 35: ...Certifying Fiber Cabling 29 amd147f eps Figure 11 Loopback Mode Reference Connections Method B...
Страница 37: ...Certifying Fiber Cabling 31 amd148f eps Figure 12 Loopback Mode Test Connections Method B...
Страница 41: ...Certifying Fiber Cabling 35 amd149f eps Figure 14 Far End Source Mode Reference Connections Method B...
Страница 45: ...Using the Visual Fault Locator 39 amd23f eps Figure 17 Using the Visual Fault Locator...
Страница 48: ...DTX MFM2 GFM2 SFM2 Fiber Modules Users Manual 42 amd58f eps Figure 19 Connections for Monitoring Optical Power...
Страница 60: ...DTX MFM2 GFM2 SFM2 Fiber Modules Users Manual B 4...