![Fluke DTX-1800 Скачать руководство пользователя страница 232](http://html.mh-extra.com/html/fluke/dtx-1800/dtx-1800_technical-reference-handbook_2309247232.webp)
DTX Series CableAnalyzer
Technical Reference Handbook
8-24
Running the Autotest in Smart Remote Mode
W
Caution
If the test reference cords have been disconnected
from the tester’s or smart remote’s output since
the reference was set, you must set the reference
again to ensure valid measurements.
18
Turn on the tester and smart remote and let them sit
for 5 minutes. Allow additional time if the modules
have been stored above or below ambient
temperature.
19
Verify that the settings described in Table 8-2 on page
8-14 are appropriate.
20
Clean and inspect the connectors on the cabling to be
tested.
21
Connect the tester to the cabling. Figure 8-11 shows
test connections for the 1 Jumper method.
22
Turn the rotary switch to AUTOTEST. Verify that the
media type is set to Fiber. Press
J
Change Media to
change it if necessary.
23
Press
P
.
24
If Open or Unknown appears as the status, try the
following:
•
Verify that all connections are good.
•
Verify that the remote tester is on.
•
Try different connections to the cabling until the
test continues. See “Using FindFiber in Smart
Remote Mode” on page 8-50 for details on
FindFiber messages.
•
Use the visual fault locator to verify fiber continuity.
25
To save the results, press
N
; then do one of the
following:
•
To save the results in a new record, select or create
a fiber ID for one fiber; then press
N
. Select or
create a fiber ID for the other fiber; then press
N
again.
•
To save the results with existing OTDR or network
connectivity results for the same link, enter the ID
of the existing results or select the ID from the Auto
Sequence ID list or the List of downloaded IDs; then
press
N
. Repeat for the other fiber.
IDs that already contain fiber results are preceded
with a “$”.
Содержание DTX-1800
Страница 4: ......
Страница 18: ...DTX Series CableAnalyzer Technical Reference Handbook xiv ...
Страница 40: ...DTX Series CableAnalyzer Technical Reference Handbook 1 14 amd30f eps Figure 1 3 Smart Remote Features ...
Страница 43: ...Getting Acquainted Basic Features 1 17 1 amd124f eps Figure 1 4 Charging and Removing the Battery ...
Страница 132: ...DTX Series CableAnalyzer Technical Reference Handbook 4 8 ...
Страница 156: ...DTX Series CableAnalyzer Technical Reference Handbook 6 12 amd100f eps Figure 6 4 Interpreting HDTDR Plots ...
Страница 158: ...DTX Series CableAnalyzer Technical Reference Handbook 6 14 ...
Страница 190: ...DTX Series CableAnalyzer Technical Reference Handbook 7 32 amd125f eps Figure 7 18 Typical OTDR Trace Features ...
Страница 264: ...DTX Series CableAnalyzer Technical Reference Handbook 8 56 amd56f eps Figure 8 28 Using FindFiber in Loopback Mode ...
Страница 270: ...DTX Series CableAnalyzer Technical Reference Handbook 8 62 ...
Страница 274: ...DTX Series CableAnalyzer Technical Reference Handbook 9 4 amd23f eps Figure 9 2 Using the Visual Fault Locator ...
Страница 284: ...DTX Series CableAnalyzer Technical Reference Handbook 10 10 ...
Страница 291: ...Verifying Network Service Verifying Network Connectivity 11 7 11 amd17f eps Figure 11 3 Network Test Connections ...
Страница 304: ...DTX Series CableAnalyzer Technical Reference Handbook 11 20 ...
Страница 372: ...DTX Series CableAnalyzer Technical Reference Handbook A 8 ...
Страница 374: ...DTX Series CableAnalyzer Technical Reference Handbook B 2 ...