background image

DSX-CHA-5-IX-S

ix Industrial

 Adapters  

for Industrial Ethernet

Users Guide

The DSX-CHA-5-IX-S is a set of two adapters for use with Fluke Networks 
DSX CableAnalyzer

 testers. The adapters let you test and certify ix 

Industrial links and patch cords to the IEEE 802.3 specifications often used 
for industrial Ethernet applications.

DSX Firmware Requirements

Your DSX CableAnalyzer will show a message if it needs a firmware update 
to operate with these adapters. Firmware updates are available at no 
charge on the Fluke Networks website. To install an update, use the latest 
version of LinkWare PC or LinkWare Live. For details, see the Versiv Series 
Users Manual.

PN 5082049  March 2019

©2019 Fluke Corporation

All product names are trademarks of their respective companies.

Содержание DSX-CHA-5-IX-S

Страница 1: ...ten used for industrial Ethernet applications DSX Firmware Requirements Your DSX CableAnalyzer will show a message if it needs a firmware update to operate with these adapters Firmware updates are ava...

Страница 2: ...tegory With reference to the equipment types in the WEEE Directive Annex I this product is classed as category 9 Monitoring and Control Instrumentation product Do not dispose of this product as unsort...

Страница 3: ...testers are at an ambient temperature between 50 F and 104 F 10 C and 40 C 2 Connect the main and remote testers together as shown at the top or bottom of Figure 1 3 On the home screen tap TOOLS then...

Страница 4: ...tap a cable type Shield Test Shows only for shielded cable types To get a FAIL result if the shield is open select On See the Versiv Series Users Manual for more information Test Limit If the correct...

Страница 5: ...igure 2 Connections for Channel Tests with Two ix Industrial Connectors Switch Channel 90 m maximum 295 ft ix Industrial connectors Variable frequency drive Main and remote testers with DSX CHA 5 IX a...

Страница 6: ...strial Connector Channel 90 m maximum 295 ft PLC Switch Variable frequency drive RJ45 cable from switch ix Industrial connector Main tester with DSX CHA004 channel adapter Remote tester with DSX CHA 5...

Страница 7: ...only for shielded cable types To get a FAIL result if the shield is open select On See the Versiv Series Users Manual for more information Test Limit If the correct patch cord limit is not in the LAST...

Страница 8: ...e latest version of firmware is available at no charge on the Fluke Networks website Contact Fluke Networks www flukenetworks com support info flukenetworks com 1 800 283 5853 1 425 446 5500 Fluke Net...

Страница 9: ...behalf To obtain service during the warranty period contact your nearest Fluke Networks authorized service center to obtain return authorization information then send your defective product to that Se...