![Fluke CableAnalyzer DSX-602 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/fluke/cableanalyzer-dsx-602/cableanalyzer-dsx-602_user-manual_2309840041.webp)
Chapter 2: Certify Twisted Pair Cabling
Settings for Twisted Pair Tests
33
Setting
Description
Store Plot Data
Off
:
The tester does not save plot data for frequency-
domain tests or for the HDTDR/HDTDX analyzers. You
can see the plots before you save the test and exit the
results screen. The saved results show frequency-domain
measurements in a table and do not include the HDTDR/
HDTDX plots.
On
:
The tester saves plot data for all frequency-
domain tests required by the selected test limit and for
the HDTDR/HDTDX analyzers.
HDTDR/HDTDX
Fail/Pass* only:
The tester shows HDTDR and HDTDX
analyzer results only for Autotests with
PASS*
,
FAIL*
,
or
FAIL
results.
All Autotests:
The tester shows HDTDR and HDTDX
analyzer results for all Autotests.
To get HDTDR/HDTDX analyzer results you can also tap
TOOLS
>
Diagnostics
.
For more information about the HDTDR and HDTDX
analyzers, see the Technical Reference Handbook.
Outlet
Configuration
The
Outlet Configuration
specifies which wire pairs are
tested and which wire numbers the wire map shows for the
pairs. See Figure 11.
To see the wire map for a configuration, tap
Outlet
Configuration
, tap the configuration name on the
OUTLET
CONFIG
screen, then tap
SAMPLE
.
To select a configuration, tap a name on the
OUTLET
CONFIG
screen, then tap
USE SELECTED
.
Note
The
OUTLET CONFIG
screen shows only the
configurations that are applicable to the
selected
Test Limit
.
To make a custom outlet configuration, tap
CUSTOM
on
the
OUTLET CONFIG
screen, then tap
MANAGE
, then tap
Create
.
Table 2. Settings for Twisted Pair Tests (continued)
Содержание CableAnalyzer DSX-602
Страница 60: ...DSX 602 CableAnalyzer Users Manual 52 ...
Страница 74: ...DSX 602 CableAnalyzer Users Manual 66 ...
Страница 100: ...DSX 602 CableAnalyzer Users Manual 92 ...