![Fluke CableAnalyzer DSP-4100 Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/fluke/cableanalyzer-dsp-4100/cableanalyzer-dsp-4100_user-manual_2309836086.webp)
DSP-4000 Series
Users Manual
3-20
Pressing
#
View Plot
produces the ACR plot screen. Figure 3-8 describes
an example of the screen.
6
5
4
3
2
1
oy12c.eps
1
The cable pairs relevant to the plot.
2
Frequency range in MHz of the ACR test. Use
U
D
to change the frequency scale.
3
The ACR level, frequency, and margin at the cursor’s position. The cursor aligns to the
frequency that produced the worst margin. Margin is the difference between the limit and
measured values plotted at the cursor’s position. Use
L R
to move the cursor left or right.
If you move the cursor beyond the highest test frequency specified by the selected test
standard, the readout shows the ACR value at the cursor’s position.
4
The ACR limits, as defined by the selected test standard. The limit line is dashed at
frequencies where the attenuation is less than 4 dB.
5
Decibels of ACR for the cable pair.
6
The calculated ACR for the cable pairs.
Figure 3-8. The ACR Plot Screen
Содержание CableAnalyzer DSP-4100
Страница 10: ...DSP 4000 Series Users Manual viii...
Страница 20: ...DSP 4000 Series Users Manual 1 8...
Страница 66: ...DSP 4000 Series Users Manual 2 46...
Страница 99: ...Autotest The Autotest Report 3 3 33 oy82f bmp Figure 3 12 Autotest Report in Tabular Format...
Страница 138: ...DSP 4000 Series Users Manual 6 6...
Страница 170: ...DSP 4000 Series Users Manual 7 32...
Страница 195: ...Appendices Appendix Title Page A Tests Supported by LIAs A 1 B Glossary B 1...
Страница 196: ......
Страница 210: ...DSP 4000 Series Users Manual B 12...
Страница 216: ...DSP 4000 Series Users Manual 6...